Item
FL display
Key operation
Mode name
Description
(Remote controller key)
RAM Drive Last Error
RAM Drive error code display.
*For details about the drive error code, refer
to the Service Manual for the specific RAM
Drive.
1. Error Number is displayed for 5
seconds.
2. Time when the error has occurred
is displayed for 5 seconds.
DD: Day
hh: Hour
mm: Minute
3. Last Drive Error (1/2) is displayed
for 5 seconds.
4. Last Drive Error (2/2) is displayed
for 5 seconds.
5. Error occurring Disc type is
displayed for 5 seconds.
6. Disc Maker ID is displayed for 5
seconds.
7. Factor of Drive Error occurring is
left displayed
Press [4] [2] in service mode.
When
“INFO******”
is
being
displayed, past 19 error histories
can be displayed by pressing [0] [1]
- [1] [9]
In case that the maker cannot be
identified, display is black out.
Delete
the
Last
Drive
Error
Delete the Last Drive Error information stored
on the DVD RAM-Drive.
Press [9] [6] in service mode.
Laser power confirmation Drive state is judged based on difference
between laser power value at shipping and
present laser power value.
If DVD-RAM disc in not inserted,
[NO DISC] is displayed.
If power value study was filed,
[ERROR] is displayed.
1.
into RAM
Drive in service mode. (Other
media are assumed to be non-
correspondence.)
2.
Press [4] [4].
Turn on all FL/LEDs
All segments of FL and all LEDs are turned
on.
All segments are turned on.
Press [5] [1] in service mode.
PB HIGH Signal Output
8 pin of AV 1 Jack (PB HIGH terminal) is High
(approx. 11V DC).
Press [5] [2] in service mode.
PB
MIDDLE
Signal
Output
8 pin of AV 1 Jack (PB HIGH terminal) is
Middle (approx. 5.5V DC)
Press [5] [3] in service mode.
24
DMR-EH55EE / DMR-EH55GC / DMR-EH55GCS / DMR-EH55GN
Содержание DMR-EH55EE
Страница 5: ...2 2 Precaution of Laser Diode 5 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 8: ...4 Specifications 8 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 9: ...9 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 11: ...11 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 12: ...12 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 13: ...13 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 16: ...16 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 36: ...11 1 2 Checking and Repairing of RAM Digital P C B Module 36 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 37: ...11 1 3 Checking and Repairing of Main P C B 37 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 38: ...11 1 4 Checking and Repairing of HDD 38 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 42: ...42 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...
Страница 48: ...DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN 48 ...
Страница 84: ...16 1 2 Packing Accessories Section 84 DMR EH55EE DMR EH55GC DMR EH55GCS DMR EH55GN ...