15
6 Service Mode
6.1.
Error Code Memory Function
1.
General description
This unit is equipped with history of error code memory function, and can be memorized 16 error codes in sequence from the
latest. When the error is occurred more than 16, the oldest error is overwritten in sequence.
The error code is not memorized when the power supply is shut down forcibly (when the unit is powered on by the battery, the
battery is pulled out) because the error code is memorized to FLASH ROM when the unit is powered off.
2.
How to display
The error code can be displayed by the following procedure:
Before perform the error code memory function, connect the AC adaptor or insert the battery.
(Since this unit has built-in memory, this error code memory function can be performed without inserting SD memory card.)
• Preparation. Set the Mode dial to “Normal Picture Mode” (Red camera mark).
Set the [REC]/[PLAYBACK] selector switch to “[ REC ] (Red camera mark)”.
•
1. The temporary cancellation of initial setting:
Set the [REC]/[PLAYBACK] selector switch to “[ REC ] (Red camera mark)”.
While keep pressing [ DISPLAY ] and “[ UP ] of Cursor buttons” simultaneously, turn the Power on.
•
2. The display of error code:
Press [ DISPLAY ], [ MENU/SET ] and “[ LEFT ] of Cursor buttons” simultaneously with the step 1 condition.
The display is changed as shown below when the above buttons is pressed simultaneously.
Normal display
→
Error code display
→
Operation history display
→
Normal display
→
.....
Example of Error Code Display
•
3. The change of display:
The error code can be memorized 16 error codes in sequence, however it is displayed 5 errors on the LCD.
Display can be changed by the following procedure:
“[ UP ] or [ DOWN ] of Cursor buttons” : It can be scroll up or down one.
“[ LEFT ] or [ RIGHT ] of Cursor buttons” : It can be display last 5 error or another 5 error.
•
4. How to read the error date:
The error date code is displayed from the left in order at the year, month, day, time.
Error date information is acquired from "Clock setting" information when the error occurs. When the clock is not setting, it is
displayed as “00000000”.
Содержание DMC-FX35E
Страница 12: ...12 4 Specifications ...
Страница 13: ...13 5 Location of Controls and Components ...
Страница 14: ...14 ...
Страница 20: ...20 8 Disassembly and Assembly Instructions 8 1 Disassembly Flow Chart 8 2 PCB Location ...
Страница 22: ...22 Fig D2 8 3 2 Removal of the LCD Unit Fig D3 8 3 3 Removal of the Front Case Unit Fig D4 ...
Страница 23: ...23 8 3 4 Removal of the Top Operation Unit Fig D5 8 3 5 Removal of the Flash Top P C B Fig D6 Fig D7 ...
Страница 50: ...S7 2 Packing Parts and Accessories Section 1 S 17 211 214 213 202 203 215 204 205 206 208 207 200 209 ...