1 Safety Precautions

1.1.

General Guidelines

1.

IMPORTANT SAFETY NOTICE

There are special components used in this equipment 
which are important for safety. These parts are marked by         

 in the Schematic Diagrams, Circuit Board Layout, 

Exploded Views and Replacement Parts List. It is 
essential that these critical parts should be replaced with 
manufacturer’s specified parts to prevent X-RADIATION, 
shock, fire, or other hazards. Do not modify the original 
design without permission of manufacturer.

2. An Isolation Transformer should always be used during 

the servicing of AC Adaptor whose chassis is not isolated 
from the AC power line. Use a transformer of adequate 
power rating as this protects the technician from 
accidents resulting in personal injury from electrical 
shocks. It will also protect AC Adaptor from being 
damaged by accidental shorting that may occur during 
servicing.

3. When servicing, observe the original lead dress. If a short 

circuit is found, replace all parts which have been 
overheated or damaged by the short circuit.

4. After servicing, see to it that all the protective devices 

such as insulation barriers, insulation papers shields are 
properly installed.

5. After servicing, make the following leakage current 

checks to prevent the customer from being exposed to 
shock hazards.

1.2.

Leakage Current Cold Check

1. Unplug the AC cord and connect a jumper between the 

two prongs on the plug.

2. Measure the resistance value, with an ohmmeter, 

between the jumpered AC plug and each exposed 
metallic cabinet part on the equipment such as 
screwheads, connectors, control shafts, etc. When the 
exposed metallic part has a return path to the chassis, the 
reading should be between 1 M

 and 5.2 M

. When the 

exposed metal does not have a return path to the chassis, 
the reading must be infinity.

1.3.

Leakage Current Hot Check 
(See Figure 1.)

1. Plug the AC cord directly into the AC outlet. Do not use 

an isolation transformer for this check.

2. Connect a 1.5 k

, 10 W resistor, in parallel with a 0.15 

µ

capacitor, between each exposed metallic part on the set 
and a good earth ground, as shown in Figure 1.

3. Use an AC voltmeter, with 1 k

/V or more sensitivity, to 

measure the potential across the resistor.

4. Check each exposed metallic part, and measure the 

voltage at each point.

5. Reverse the AC plug in the AC outlet and repeat each of 

the above measurements.

6. The potential at any point should not exceed 0.75 V RMS. 

A leakage current tester (Simpson Model 229 or 
equivalent) may be used to make the hot checks, leakage 
current must not exceed 1/2 mA. In case a measurement 
is outside of the limits specified, there is a possibility of a 
shock hazard, and the equipment should be repaired and 
rechecked before it is returned to the customer.

Figure. 1

Содержание DMC-F5EB

Страница 1: ... law ORDER NO DSC1302008CE B26 Digital Camera Model No DMC F5P DMC F5PC DMC F5PU DMC F5EG DMC F5EP DMC F5EF DMC F5EB DMC F5EE DMC F5GC DMC F5GF DMC F5GA DMC F5GW DMC F5GT DMC F5GK DMC F5GN Colour S Silver Type except DMC F5P PC EF GN K Black Type P Pink Type except DMC F5P PC EE GK GW ...

Страница 2: ... 7 3 1 Introduction 7 3 2 General Description About Lead Free Solder PbF 7 3 3 Important Notice 7 3 4 How to Define the Model Suffix NTSC or PAL model 8 4 Specifications 11 5 Location of Controls and Components 12 6 Service Fixture Tools 14 6 1 Service Fixture and Tools 14 7 Disassembly and Assembly Instructions 15 7 1 Disassembly Flow Chart 15 7 2 PCB Location 15 7 3 Disassembly Procedure 16 8 Me...

Страница 3: ...sed to shock hazards 1 2 Leakage Current Cold Check 1 Unplug the AC cord and connect a jumper between the two prongs on the plug 2 Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metallic cabinet part on the equipment such as screwheads connectors control shafts etc When the exposed metallic part has a return path to the chassis the reading should be bet...

Страница 4: ...rging Procedure 1 Refer to the disassemble procedure and remove the necessary parts unit 2 Install the insulation tube onto the lead part of resistor ERG5SJ102 1kΩ 5W an equivalent type of resistor may be used 3 Place a resistor between both terminals of E capacitor on the Flash Unit for approx 5 seconds 4 After discharging confirm that the E capacitor voltage is lower than 10V using a voltmeter F...

Страница 5: ... solder or unsolder ES devices 4 Use only an antistatic solder removal device Some solder removal devices not classified as antistatic ESD protected can generate electrical charge sufficient to damage ES devices 5 Do not use freon propelled chemicals These can generate electrical charges sufficient to damage ES devices 6 Do not remove a replacement ES device from its protective package until immed...

Страница 6: ...6 2 2 How to recycle the lithium Ion Battery U S Only 2 3 About the Battery pack ...

Страница 7: ...air work using Lead Free Solder PbF The lead free solder has to be used when repairing the equipment for which the lead free solder is used Definition The letter of PbF is printed on the P C B using the lead free solder To put lead free solder it should be well molten and mixed with the original lead free solder Remove the remaining lead free solder on the P C B cleanly for soldering of the new IC...

Страница 8: ...PU GC GA GF GW What is the difference is that the Initial Setting data which is stored in Flash ROM mounted on MAIN P C B 3 4 1 Defining methods To define the model suffix to be serviced refer to the nameplate which is putted on the bottom side of the Unit NOTE After replacing the MAIN P C B make sure to perform the Initial Setting and adjustment The adjustment software is available at TSN Website...

Страница 9: ... camera b Connect the camera and PC by USB cable c Copy PcAppSample_F5 exe profile ini and UI43Api dll to the same directory of your PC 2 Execute the Initial Setting a Turn on the power of camera b Select the USB mode to PC on LCD display c Execute the PC software PcAppSample_F5 exe d Select Sales Area and click OK then the window is changed e Select the color of camera f Input the Serial Number b...

Страница 10: ... Input any 14 digits into ML WAB NUM area h Window show green OK when success if window show NG note the NG items i Click OK to complete initial setting j Turn off the power of DSC and disconnect USB cable ...

Страница 11: ...11 4 Specifications NOTE The following specification is for DMC F5 Some specifications may differ depending on model suffix ...

Страница 12: ...12 5 Location of Controls and Components NOTE The following description is for DMC F5 Some descriptions may differ depending on model suffix ...

Страница 13: ...13 ...

Страница 14: ...14 6 Service Fixture Tools 6 1 Service Fixture and Tools The following Service Fixture and tools are used for checking and servicing this unit REMARKS 1 ABOUT LIGHT BOX ...

Страница 15: ...15 7 Disassembly and Assembly Instructions 7 1 Disassembly Flow Chart This is a disassembling chart When installing perform this chart conversely 7 2 PCB Location ...

Страница 16: ... Case Unit Fig D5 Caution for Discharging 4 LCD Unit Fig D6 4 Screws C Frame Plate Fig D7 LCD Bracket Connector A LCD Unit 5 Main P C B Fig D8 4 Screws D 20 Solders Fig D9 1 Solder Connector B Connector C Lens Unit W CCD Main P C B 6 CCD Unit and Lens Unit Fig D10 3 Screws E CCD Unit CCD Cushion Optical Filter Lens Unit 7 Flash Unit Fig D11 Flash Sheet AF Panel Light 2 Screws F Flash Unit 8 Batter...

Страница 17: ...17 7 3 2 Removal of the Rear Case Unit Fig D3 7 3 3 Removal of the Top Case Unit Fig D4 Fig D5 ...

Страница 18: ...18 7 3 4 Removal of the LCD Unit Fig D6 Fig D7 7 3 5 Removal of the Main P C B Fig D8 ...

Страница 19: ... Take care that the dust and dirt are not entered into the lens In case of the dust is putted on the lens blow off them by airbrush 2 Do not touch the surface of lens 3 Use lens cleaning KIT BK VFK1900BK 4 To prevent the CCD surface from catching a dust and dirt do not remove the CCD unit except for replacing Fig D10 ...

Страница 20: ...t Fig D12 NOTE When Installing Make sure to confirm the following points when installing The Screw is tightened enough Installing conditions are fine No distortion no abnormal space No dust and or dirt on Lens surfaces LCD image is fine No dust and dirt on it and no gradient images ...

Страница 21: ...he PDME570C elf and cal txt software The Adjustment software PDME570C elf and cal txt together with its installation instruction are available at TSN Website 8 2 Matrix chart Replaced part and Adjustment item The following matrix table shows the relation between the replaced part and the necessary adjustment When a part is replaced make sure to perform the necessary adjustment s in the order indic...

Страница 22: ...rd c Press shutter button and power button at the same time continuously to enter into the CAL mode Fig 1 1 Fig 1 1 d Set the lens to the center of the light box s front side 3 Execute the calibration a Press shutter button to start the calibration process b The parameters will be saved automatically once the calibration process finish c The LCD turns gray and show Defectpixel Fig 1 2 if succeed L...

Страница 23: ...ess shutter button and power button at the same time continuously to enter into the CAL mode Fig 2 1 Fig 2 1 d Set the lens to the center of the light box s front side 3 Execute the calibration a Press shutter button to start the calibration process b The parameters will be saved automatically once the calibration process finish c The LCD turns green and show OK Fig 2 2 if succeed LCD turns red an...

Страница 24: ... same time continuously to enter into the CAL mode Fig 3 1 Fig 3 1 d Set the collimator s star chart side to the front of light box e Set the lens to the center of the collimator on the opposite side of the light box 3 Execute the calibration a Press shutter button to start the calibration process b The parameters will be saved automatically once calibration process finish c The LCD turns green an...

Страница 25: ... Press shutter button and power button at the same time continuously to enter into the CAL mode Fig 4 1 Fig 4 1 3 Execute the calibration a Press shutter button to start the calibration process b The parameters will be saved automatically once calibration process finish c The LCD turns green and show OK Fig 4 2 if succeed LCD turns red and show NG code if fail It takes about 30 minutes during exec...

Страница 26: ...CD Panel with your hand When cleaning the lens use air Blower to blow off the dust When cleaning the LCD Panel dampen the lens cleaning paper with lens cleaner and the gently wipe the its surface Note The Lens Cleaning KIT VFK1900BK Only supplied as 10 set Box is available as Service Aid ...

Страница 27: ...27 10 Wiring Connection Diagram SPEAKER MICROPHONE CCD UNIT LENS UNIT LCD UNIT BATTERY FLASH P C B COMPONENT SIDE MAIN P C B COMPONENT SIDE FOIL SIDE ...

Отзывы: