79
FX-301
FD-EG1
FD-EG2
FD-EG3
FD-E12
FD-E22
FD-EN500S1
FD-ENM1S1
LIST OF FIBERS
Special use
Wide beam
Arr
a
y
High precision
Ultr
a-small diameter
Liquid le
v
el sensing
T
ough fle
xib
le
Fix
ed-f
ocus reflectiv
e
Special use fibers (Reflective type)
:LONG
:STD
:FAST
:S-D
Sensing range (mm
in
) (Note 1, 2)
Red LED
Blue LED Green LED Infrared LED
200
7.874
150
5.906
100
3.937
50
1.969
38
1.496
18
0.709
14
0.551
220
8.661
110
4.331
78
3.071
39
1.535
110
4.331
55
2.165
42
1.654
19
0.748
6
0.236
25
0.984
12
0.472
9
0.354
5
0.197
15
0.591
8
0.315
5
0.197
3
0.118
11
0.433
6
0.236
4
0.157
1
0.039
45
1.772
23
0.906
17
0.669
7
0.276
5
0.197
3
0.118
2
0.079
Cannot use
38
1.496
18
0.709
14
0.551
6
0.236
0 to 20
0 to 0.787
2.5 to 18
0.098 to 0.709
(Convergent point 8
0.315
)
3 to 16
0.118 to 0.630
(Convergent point 8
0.315
)
3.5 to 15
0.138 to 0.591
(Convergent point 8
0.315
)
Cannot use
0.5 to 4
0.020 to 0.157
(Convergent point 2
0.079
)
1 to 3.8
0.039 to 0.150
(Convergent point 2
0.079
)
1.3 to 3.5
0.051 to 0.138
(Convergent point 2
0.079
)
Cannot use
2.5 to 18
0.098 to 0.709
(Convergent point 6
0.236
)
4 to 12
0.157 to 0.472
(Convergent point 6
0.236
)
4.5 to 11
0.177 to 0.433
(Convergent point 6
0.236
)
4.8 to 9.5
0.189 to 0.374
(Convergent point 6
0.236
)
185
7.283
80
3.150
35
1.378
90
3.543
45
1.772
60
2.362
35
1.378
20
0.787
Notes: 1) The sensing range is specified for white non-glossy paper [100
100 mm
3.937
3.937 in
(
FD-A15
,
FD-G4
,
FD-G6X
: 200
200 mm
7.874
7.874 in
,
FD-AFM2
,
FD-AFM2E
,
FD-P81X
: 400
400 mm
15.748
15.748 in
,
FD-L43
: glass substrate 76
52
t 1.1 mm
2.992
2.047
t 0.043 in
,
FD-L41
:
glass substrate 100
100
t 2 mm
3.937
3.937
t 0.079 in
)] as the object.
Notes:
2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes:
3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum sensing
object size if using amplifiers other than red LED type.
Also, note that the corresponding setting distance is different from the rated sensing distance. However, with the fixed-focus reflective type, when the
sensitivity is at MAX., it is only possible to detect the minimum size of the sensing object at a distance corresponding to the convergent point.
Notes:
4) Following is the allowable cutting range from the end that the amplifier is inserted
FD-F8Y
: 1,000 mm
39.370 in
,
FD-G6X
: 700 mm
27.559 in
.
Allowable
bending
radius
Model No.
25
0.984
15
0.591
40
1.575
20
0.787
13
0.512
22
0.866
11
0.433
8
0.315
6
0.236
3
0.118
2
0.079
5
0.197
2
0.079
1
0.039
2
0.079
1
0.039
2
0.079
1
0.039
6
0.236
3
0.118
2
0.079
6
0.236
3
0.118
2
0.079
4.5 to 9.5
0.177 to 0.374
5 to 9
0.197 to 0.354
5.5 to 8
0.217 to 0.315
32
1.260
16
0.630
10
0.394
22
0.866
11
0.433
6
0.236
18
0.709
9
0.354
5
0.197
12
0.472
6
0.236
4
0.157
3
0.118
1.5
0.059
1
0.039
2
0.079
1
0.039
1
0.039
1
0.039
3
0.118
1.5
0.059
1
0.039
3
0.118
1.5
0.059
1
0.039
12
0.472
6
0.236
4
0.157
7
0.276
3.5
0.138
2
0.079
10
0.394
5
0.197
3
0.118
6
0.236
3
0.118
2
0.079
3
0.118
1.5
0.059
1
0.039
1
0.039
6
0.236
3
0.118
2
0.079
4
0.157
2
0.079
1.5
0.059
5 to 9
0.197 to 0.354
5.5 to 8
0.217 to 0.315
4.5 to 9.5
0.177 to 0.374
16
0.630
8
0.315
5
0.197
12
0.472
6
0.236
4
0.157
30
1.181
15
0.591
10
0.394
18
0.709
9
0.354
5
0.197
"
0.02 mm
"
0.0008 in
gold wire
"
0.02 mm
"
0.0008 in
gold wire
"
0.02 mm
"
0.0008 in
gold wire
"
0.06 mm
"
0.0024 in
gold wire
"
0.03 mm
"
0.0012 in
gold wire
"
0.02 mm
"
0.0008 in
gold wire
"
0.02 mm
"
0.0008 in
gold wire
(LCD glass)
(Liquid)
(Liquid)
"
0.04 mm
"
0.0016 in
gold wire
"
0.02 mm
"
0.0008 in
gold wire
FD-A15
FD-L41
FD-L42
FD-L4
FD-P81X
FD-G6X
FD-AFM2
FD-AFM2E
FD-G4
FD-G6
FD-L43
FD-F8Y
FD-F41
FD-F91
FD-F4
FD-F9
500 mm
19.685 in
1 m
3.281 ft
500 mm
19.685 in
1 m
3.281 ft
1 m
3.281 ft
2 m
6.562 ft
5 m
16.404 ft
2 m
6.562 ft
5 m
16.404 ft
R10 mm
R0.394 in
R10 mm
R0.394 in
R4
R0.157
R10 mm
R0.394 in
R10 mm
R0.394 in
R10 mm
R0.394 in
R25 mm
R0.984 in
R25 mm
R0.984 in
R25 mm
R0.984 in
R25 mm
R0.984 in
Protective tube
R40 mm
R1.575 in
Fiber
R15 mm
R0.591 in
Applicable pipe diameter:
Outer dia.
"
6 to
"
26 mm
"
0.236 to
"
1.024 in
transparent pipe
[PVC, fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm
0.039 to 0.118 in
]
Applicable pipe diameter:
Outer dia.
"
6 to
"
26 mm
"
0.236 to
"
1.024 in
transparent pipe
[PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm
0.039 in
]
W7
H15
D30
W0.276
H0.591
D1.181
Top sensing
W5
H20
D20
W0.197
H0.787
D0.787
Side sensing
W5
H20
D20
W0.197
H0.787
D0.787
Coaxial
Lens mountable
Coaxial
Lens mountable
Coaxial
Lens mountable
Coaxial
Lens mountable
Coaxial
Lens mountable
Coaxial
Coaxial
Sleeve part cannot be bent.
Sleeve part cannot be bent.
Sleeve part cannot be bent.
Sleeve part cannot be bent.
Glass substrate detection
SEMI S2 compliant
W17
H29
D3.8
W0.669
H1.142
D0.150
Glass substrate detection
W24
H21
D4
W0.945
H0.827
D0.157
Specular object detection
W15
H19
D3
W0.591
H0.748
D0.118
W6
H18
D14
W0.236
H0.709
D0.551
Mountable on pipe
Standard
W25
H13
D20
W0.984
H0.512
D0.787
Mountable on pipe
For PFA, wall
thickness 1 mm
0.039 in
pipe
W25
H13
D20
W0.984
H0.512
D0.787
Contact type
"
6
"
0.236
Small spot for sensing minute objects
Coaxial
High precision
Type
Shape of fiber head
(mm
in
)
Min. sensing object
at the maximum
sensitivity (Note 3)
2 m
6.562 ft
2 m
6.562 ft
2 m
6.562 ft
2 m
6.562 ft
2 m
6.562 ft
(Note 4)
1 m
3.281 ft
(Note 4)
Fiber cable
length
: Free-cut
Содержание Digital Fiber Sensor FX-301
Страница 64: ...527 FX 301 F ...