Unscrew the cord holder and fi x the cable. Strip the cable (coating).
Loosen the screw and fasten the live wire (L) and neutral wire (N) to the ELB (L,N); insert the earth wire
under the Earth Plate to the Ground Point with 1 N.m (10 k
g
f.cm) torque. Fix back the cord holder to its
position to clamp the cable.
5 mm
L
N
ELB Terminal
Ground Point
1 N.m
40 mm
13 mm
50 mm
13 mm
L
N
Connect wires in correct polarity (L,N).
• Connecting wires in wrong polarity (L,N) causes an abnormal condition which may lead to electric leaking, burning,
and such.
• Before wiring, please check polarity (L,N) with voltage range of a tester or voltmeter by connecting one terminal of
the tester to earth while the other to one of the Power Supply terminal.
• When the needle of the tester defl ects greatly, the polarity of the Power Supply terminal is "L".
Main Power Board
Power-Supply
Terminals
Tester
Earth
Earth
Rod.
WARNING
The appliance must be earthed. Improper grounding could
cause electric shock.
• Earth Rod handling procedure. Select adapter place to bury the optional Earth Rod (DQ-6H) for at least 70 cm
below ground surface.
• Ensure that the ground resistance is less than 100
. If it is not, drive the Rod deeper into ground surface or use 2
or 3 Rods.
Ground
Surface
Burying tool
Earth Rod
70 cm at least
70 cm at least
(Bevel Style)
(Parallel Style)
70 cm at least
About 2 m About 2 m
Connection
Connection
1 m
5. Piping installation procedure.
Note:
• Make sure no water leaks from pipe connection.
• When glue is used for external piping connection, must wait for the glue to dry before proceeded to test run with
water.
WARNING
Do not share the inlet pipe of the appliance with other outlets.
The pressure may drop due to water being drawn off at other
point. The water temperature may become very hot.