![Panasonic DH-3ND1 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/panasonic/dh-3nd1/dh-3nd1_operating-instructions-manual_258112037.webp)
1. • Before switch “ON” electricity supply check the wiring.
• Switch “ON” the Miniature Circuit Breaker (MCB) and ON/OFF DP (double pole) Switch.
• Set the ELB of the Unit to “On”. (Push up the ELB Reset Lever if it is down)
• Push the ELB Test Button.
• It is normal if the ELB turns “Off” (the ELB Reset Lever falls) and push the ELB Reset Lever up.
Refer figure as shown.
• Inspection on the built-in ELB (once a month) to avoid a hazard to users such as damage to
property, serious injury or death.
3. TEST OPERATION
Push
ELB
Test Button
ELB
Reset Lever
ELB Test
ELB Reset
Push Up
Push On-Off
Hot
Health
Safe
Bubble
o
C
Beat
Level
Normal
Cool
e-Cycle
Set
Max
PM
e-Hybrid
+
-
2. • Turn “On” the Main Water Valve.
• Turn clockwise the Water Volume Knob.
• Check if water leaks from the Pipe Line.
3. • Press the PUSH On-Off Lever once, the LCD Panel will be activated and water start flowing out of the Shower Head.
• Adjust the water temperature using "-" or "+" Button to reduce or increase the shower temperature
4. • Refer detail for HOW TO USE and WATER FLOW RATE ADJUSTMENT on page 26 & 29.
If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down
during operation, please do not use the Unit and contact the authorized dealer
immediately to avoid a hazard to users such as damage to property, serious injury or
death. Never fix the ELB Reset Lever forcibly with tape, etc.
WARNING
ENGLISH
INST
ALLA
TION
- 37 -