2.

How to install the board

  ・

 Disconnect the CN033 (White), CN103 (Green), CN102 (Red), CN100 (White), CN082 (White)

            CN104 (Yellow) connectors from the indoor control PCB and take out the indoor control PCB. (Fig.5)

   

* When you take out the indoor control PCB, lift the tab holding the indoor control PCB. (Fig.6)

  ・

 Connect the 3P connector (yellow) of the power cables (supplied part

 

) to the

            CN309 OP1 connector (yellow) on the indoor control PCB. (Fig.5)

  ・

 Connect the 5P connector (black) of the signal output cables (supplied part 

) to 

            the CN081 3WAY connector (black) on the indoor control PCB. (Fig.5)

  ・

 Connect the removed connectors to their original positions on the indoor control PCB and insert the PCB. (Fig.5)

   

* Be sure to connect all the connectors.

3P Yellow

To indoor control PCB

OP1(CN309)

3P White

Power cables (supplied part

 

)

5P Black

To indoor control PCB

3WAY (CN081)

6P White

Signal output cables (supplied part 

)

Optional parts

Solenoid valve kit

9P Red

CN003

9P Red

Spacers (4 locations)

OPTION/3WAY

(CN001)

6P White

POWER

(CN002)

3P White

Board Insertion direction

Fig.7

Fig.8

Protective ground screw

Clamp position for 

Solenoid valve kit wiring

3.

How to attach the grille

  ・

Fit the grille to the three tabs on the upper part of the frame and attach the grille. (Fig.3)

  ・

Press the grille to its original position. Attach six screws and two screw covers. (Fig.1)

   

* For the screws on the front, attach screws in turn from the electrical component box side.

  ・

Warp the lower flap and fit the pins to the grooves on the grille to attach the flap. (Fig.2)

  ・

Close the front panel. (Fig.1)

  ・

 Clamp the wiring from the solenoid valve kit. (Fig.8)

  ・

 Connect the solenoid valve kit ground wire to the indoor unit ground wire mounting position. Also connect the 9P connector (red)

   

 of the solenoid valve kit to the CN003 9P connector (red) on the solenoid valve control PCB. (Fig.7, 8)

  ・

 Connect the 3

  ・

 Remove the screw and the cover.(Fig.5)

P connector (white) of the power cables (supplied part 

) to the CN002 POWER connector (white) 

            on the solenoid valve control PCB (supplied part 

) (Fig.7)

  ・

 Connect the 6P connector (white) of the signal output cables (supplied part 

) to the CN001 3WAY connector (white) 

            on the solenoid valve control PCB.(Fig.7 )

  ・

 Insert the solenoid valve control PCB into its mounting position. (Fig.6)

   

* Pay attention to the insertion direction of the solenoid valve control PCB. (Fig.7)

   
  ・

 Attach the screw and the cover.(Fig.5)

   

r.

  ・

 Hook the upper tab of the electrical component box cover to the electrical component box first, and then fit the lower tab. (Fig.4, 6)
* Pay attention not to catch the wires in the electrical component box cove

Solenoid Valve Control PCB

mounting position

Lower tab

Tab for holding

Indoor control PCB

Fig.6

CN309(Yellow)

CN081(Black)

CN104(Yellow)

CN102(Red)

CN103(Green)

CN033(White)

CN082

Cover

Screw

(White)

CN100(White)

Indoor control PCB

Fig.5

Printed in Japan          85464369394010