This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed water on the
condenser coil for maximum cooling efficiency, thus producing a splashing sound. If the splashing sound annoys
you, you can provide an outside drainage by using the following procedure which may, however, cause a small
loss of performance.
NOTE:
If the unit is installed at coastal area, drainage of condensed water is recommended to prevent the
condenser being corroded easily.
1
Remove the rubber plug and chassis locking
bracket from the cabinet. Then slide the chassis
out from the cabinet.
3
Connect a drain hose. Fit the drain hose to the
drain pan.
Underside view with drain
pan and hose in place.
EXTERNAL VIEW
CONDENSED WATER DRAINAGE
INSTALLATION PROCEDURES
1
Remove the rear cabinet screws and
chassis locking bracket from the cabinet.
Slide the chassis out from the cabinet.
2
3
Place cabinet into the installation hole.
4
Slide the chassis into the cabinet.
Lock the chassis to the cabinet reusing the
chassis locking bracket and screw.
Depending upon the location of the AC outlet,
route the AC cord to either the left or right side
while installing the front grille.
5
Secure it with wood screws or nails.
Tilt down for better
drainage (max. 10mm).
4
AIR CONDITIONER INSTALLATION
This figure shows the AC cord routed to the left
side.
6
Attach the front grille to the cabinet and fasten it with screws.
Screws
INTERNAL VIEW
Drain pan
Drain hose
NOTE:
Drain hose or tubing can be purchased
locally to satisfy your particular needs.
Remove the
rubber plug
2
4
Slide the chassis back into the cabinet. Lock the
chassis to the cabinet reusing the chassis
locking bracket and screw.
Slide the fro
Insert hook of string in the hole provision of the intake grille.
nt intake grille slightly to the right to reattach the tabs
and then push it down to close tight.
• Always use at the rated voltage and with a specific air conditioning circuit.
• This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit
Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock or fire in case
of malfunction.
• A 16 Ampere time delay fuse or circuit breaker is required.
• Nominal cross sectional area of power supply wire must be 3 core x 1.5 mm
2
or above.
• The power supply must be from an independent circuit.
• All electrical installations must be made in accordance with local wiring and safety regulations wherever
applicable.
• There must be a double pole switch with a minimum of 3.5 mm contact gap in the fixed installation circuit.
(Applicable for models without power supply plug only.)
• Please engage an authorized dealer or specialist for the installation work.
ELECTRIC WORK
OFTH0810-00
8
7
Unscrew and remove the
rear top cabinet screw.
(For transportation
purpose only)
Unscrew and remove the
rear bottom cabinet
screws (2pcs) and save
for later use.
Printed in Philippines
• Select an installation location that can support the weight of the air
conditioner and one that will not cause increased operating noise and
vibration.
• Ensure that airflow and noise from the rear side of the unit (outdoor)
when installed do not disturb neighbouring residents.
• Obstacles placed in front of the air outlet on the rear side of the unit
(outdoor), or covers placed over it will cause excessive noise and
deterioration in performance.
NOISE CONSIDERATION
• Repositioning or transfer of the air conditioner due to renovation or moving requires an additional service
charge. Please consult your dealer before moving.
TRANSFERRING
5
ENERGY SAVING HINTS
• Do not overcool the room. This may affect your well-being as well as increase power consumption.
• The cooling capacity of the room air conditioner must match the room size for efficient and satisfactory
operation.
• Keep all doors and windows closed. Prevent hot air from entering and cool air from escaping.
• Ensure that curtains and drapes are always closed to keep out direct sunlight during cooling operation.
Avoid heat.
• Clean the air filter every 2 weeks. Dirty filters may reduce cooling efficiency.
6
CARE AND MAINTENANCE
Always turn off the air conditioner and the main power supply before
clean the unit.
Switch off the power supply if the unit is not going to be used for a
long period of time.
• Clean the cabinet, front grille with a mild soap or detergent and lukewarm water.
• The front intake grille can be easily removed for cleaning purposes (refer to
Remove the front intake grille
procedures). Gently wash it with water and a sponge.
• The filter can be easily cleaned using a vacuum cleaner. Vacuum the front of the filter and then wash the rear
with water. If it is badly soiled, wash with a mild household detergent. (refer to
Remove the air filter procedures
).
• Do not clean with benzene, thinner, scouring powder or cloth soaked in caustic chemicals.
• If the unit is extremely dirty, heat transfer is less efficient and the unit may not cool effectively. Please contact
Shun Hing Electric Service Centre Ltd. for an annual check. (Annual check is not covered under warranty)
• If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to
operate the air conditioner will be wasted.
NOTE:
Do not dry the front panel or the air filter in direct sunlight. (Exposure to direct sunlight may discolour or
deform the panel.)
PRE-SEASON INSPECTION
•
Is the discharged air cold?
After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air to be
more than 8°C for cooling.
•
Are the air intake and outlet vanes of the indoor and outdoor side obstructed?
RECOMMENDED INSPECTION
• Usage over several seasons will reduce performance as the unit becomes dirty.
A dirty unit may produce foul odours and dust may clog the dehumidifying drainage.
Seasonal inspection is recommended in addition to regular cleaning. Consult Shun Hing Electric Service
Centre Ltd..
Condition
2
Check the following points before calling for repairs or service. If the malfunction persists,
please contact Shun Hing Electric Service Centre Ltd..
BEFORE
7
BEFORE CALLING FOR SERVICE
Condition
1
If the unit is too noisy during operation.
The following sounds are normal during operation:
• A low humming sound indicating that the unit is operating.
• A soft clicking sound when the compressor turns on and off.
• A flowing sound due to circulation of the refrigerant when the compressor is turned on.
• A splashing sound indicating condensation in the condenser coil.
If you hear other noises, please consult Shun Hing Electric Service Centre Ltd..
If the unit does not operate.
• The main power cord is not plugged in.
• The main circuit breaker has tripped.
If water drips off the rear of the unit.
• Humidity is high.
• Condensed water is overflowing.
• To rectify the problem, mount an optional drain pan to the unit.
If water drips inside the room.
• The unit is tilted inward. To rectify this, tilt the unit slightly outward.
• Mount the optional drain pan if you prefer.
• The drain pan may be blocked.
Condition
4
Condition
5
Condition
3
If the unit does not cool properly.
• The thermostat control knob is set at below 6.
• The room is too big for the unit’s cooling capacity.
• The ventilation lever is set to OPEN.
• The air circulation is impeded by curtains or furniture.
• After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air to be
more than 8°C for cooling.
To call Shun Hing Electric Service Centre Ltd. IMMEDIATELY
Turn off the power and contact Shun Hing Electric Service Centre Ltd. as soon as any of the
following events occur.
• The circuit breaker frequently trips.
• If water or foreign objects have accidentally entered the air conditioner.
• If there is abnormal sound during operation.
NOTE:
1. The enclosure opposing the room side is splash proof (IPX4).
2. Do not install this appliance in a laundry room or other locations where water may drip from the ceiling, etc.
3. If the supply cord is damaged or need to be replaced, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
CAUTION
Install the drain pan.
Install the drain pan at the right corner of the
cabinet using 2 screws.
Clockwise
WARNING
Insert front grille tabs
into the cabinet slots
Attach air filter to the front grille. (See anti-bacterial filter installation
instructions included in this package)
•
F568442_EN
1/20/09, 5:29 PM
1