Panasonic CW-UC1815AF Скачать руководство пользователя страница 3

SAFETY PRECAUTIONS

Please observe these following safety precautions when using your air conditioner.
     Failure or negligence in observing these safety precautions could cause fire, 
     electrical shock or personal injury.

This sign warns of risk of death or serious injury.

This sign warns of risk of injury or damage to property.

INSTALLATION PRECAUTIONS

Do not install, remove and reinstall the unit yourself.

Improper installation may cause leakage, electronic shock or fire.
Please engage an authorized dealer or specialist for the installation work.

Do not add or replace refrigerant other than the specified type.

It may cause product damage, burst and injury. If the supply cord is
damage, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.

The room air conditioner must be earthed.

         Improper grounding could  cause electric shock.

Do not install the unit in place where there are explosive gas leaks.

         Gas leaks near unit could cause fire.

Ensure that the drainage piping is connected properly.

         Otherwise, water will leak out.

OPERATION PRECAUTIONS

This sign warns of risk of death or serious injury.

 

Do not modify the length of the power cord or use an extension cord.

 

Do not touch or operate with wet hands.

 

Do not modify or damage the cord.

 

Do not turn on the on the unit by inserting the power plug. Do not switch off the unity by pulling out 

the power plug.

 

Avoid an extended period of direct airflow.

 

Do not insert your  fingers or other objects into the unit, rotating parts may cause injury .

 

Do not try to repair unity yourself.

 

Plug in properly before operating and use a specified power cord.

 

If abnormal conditions (burnt smell, etc)  occur switch off and remove the power plug.

 

Confirm  to  authorized  dealer  or  specialist  on  usage  of  specified  refrigerant  type.  Using  of 

refrigerant other than the specified may cause product damage, burst and injury etc.

 

This  appliance  is  not  intended  for  use  by  persons  (including,  children)with  reduced  physical 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a person responsible their safety. 
Children should be supervised to ensure that they do not play with the appliance.

This sign warns of risk of injury or damage to property.

 

Do not use the unit for other purposes, than its intended use.

 

Do not remove the power plug by pulling the cord.

 

Do not block the air intake and outlet vanes.

 

Do not splash or direct water at the unit.

 

Do not expose the unit to direct sunlight during operation.

 

Do not operate the unit without the air filter installed or when the front intake grille has been 
removed .

 

Do not place any object on the unit.

 

Do not operate any combustion equipment  near the unit's airflow area.

 

Do not sit or step on the unit, You may fall down accidentally.

 

Do not  touch the sharp aluminium fin, sharp parts may cause injury.

 

Switch off the breaker and unplug the unit form the sockets if the unit will not be operated for a long 
period.

 

Pay attention to any damage on the unit caused by extensive usage.

 

Ventilate the room occasionally where the unit is installed.

 

Unplug the power cord when cleaning the unit.

CAUTION

WARNING

CAUTION

WARNING

WARNING

CAUTION

2

Содержание CW-UC1815AF

Страница 1: ...ms Circuit Board Diagrams Exploded Views and Replacement Parts List It is essential that these critical parts should be replaced with manufacturer s specified parts to prevent shock fire or other hazards Do not modify the original design without permission of manufacturer ServiceManual MODELS CW UC1815AF CW UC2415AF Order No APIN1504003CE Destination OMAN ...

Страница 2: ......

Страница 3: ...may cause injury Do not try to repair unity yourself Plug in properly before operating and use a specified power cord If abnormal conditions burnt smell etc occur switch off and remove the power plug Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified may cause product damage burst and injury etc This appliance is not inte...

Страница 4: ...3 DIMENSIONS ...

Страница 5: ...WIRING DIAGRAM 4 CW UC1815AF CW UC2415AF ...

Страница 6: ...5 ...

Страница 7: ...6 ...

Страница 8: ...k the chassis to the cabinet with screws Tilt down for better drainage max 10mm Secure it with wood screws or nails 6 7 Depending upon the location of the AC outlet route the AC cord to either the left or right side while installing the front grille Attach the front grille to the cabinet and fasten it with a screw This figure shows the AC cord routed to the left side 7 ...

Страница 9: ...DRAIN WATER T o achieve maximum cooling efficiency the airconditioner is designed to splash the condensation water on the condenser coil In order to avoid the splashing sound an external drain can be provided by using the following procedure This may however cause a small loss of performance 1 Slide out the chassis from the cabinet 2 Remove the rubber plug from the body base plate 3 Install the dr...

Страница 10: ...HOW TO OPERATE 9 1 2 3 4 ...

Страница 11: ...CARE AND MAINTENANCE 10 ...

Страница 12: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 19 20 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 42 43 45 46 EXPLODED VIEW EXPLODED VIEW 11 ...

Страница 13: ...All parts are supplied from APIN India Vendor Code 00026071 o marked parts are recommended to be kept in stock W2C SER AC 011 1836 12 ...

Отзывы: