background image

 1. Remove the Front Intake Grille (refer to page 15).

 2. Remove the Air Filter (refer to page 15).

 3. Remove the Front Grille (refer to page 15).

 4. Remove the 2 knobs.

 5. Take off the Control Panel.

 6. Release the thermostat sensor from the sensor holder.

 7. Loosen the 3 screws of the Control Board.

 8. Slide the Control Board out from the chassis.

Control Board Part Location

11 Service Information

11.1. Removal of the Control Board

20

CW-C180ES / CW-C240ES / CW-A180ES / CW-A240ES / CW-SC180ES

Содержание CW-C180ES

Страница 1: ...s 9 2000 Matsushita Industrial Corp Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law CW C180ES CW C240ES CW A180ES CW A240ES CW SC180ES 8 How to Install...

Страница 2: ...odel CW A180ES CW A240ES Cooling Heating Cooling Heating Phase Single Single Voltage 220 V 220 V Frequency 60 Hz 60 Hz Capacity 5 13 kW 17 500 Btu h 4 60 kW 15 700 Btu h 6 45 kW 22 000 Btu h 5 60 kW 1...

Страница 3: ...32 220 F 12 19 32 320 10 1 4 260 G 4 11 32 110 9 7 16 240 H 13 5 32 334 12 3 4 324 I 5 3 16 132 7 9 16 192 J 9 7 32 234 10 254 K 3 5 32 80 L 12 17 32 318 M 10 5 16 262 N 1 21 32 42 O 12 17 32 318 P 2...

Страница 4: ...ow 41 1 27 13 Capacitor CWA312048 5 F 440VAC CWA312052 8 F 440VAC 3 1 2 Resistance of Compressor windings and the rated Capacitor CW C180ES CW SC180ES CW C240ES Connection 2KS282H6CA02 2JS350H4CA02 C...

Страница 5: ...Capacitor CWA312048 5 F 440VAC CWA312052 8 F 440VAC 3 2 2 Resistance of Compressor windings and the rated Capacitor CW A180ES CW A240ES Connection 2KS282H6CA02 2JS350H4CA02 C R 1 239 0 934 C S 1 721...

Страница 6: ...78 88 B 2 55 2 75 54 64 2 67 2 87 53 63 C 0 63 0 69 10 15 0 57 0 62 9 14 D 0 58 0 64 9 14 0 55 0 60 8 13 Note Indoor temperature at 29 C DB 19 C WB and Outdoor at 46 C DB 24 C WB for Cooling 4 2 2 He...

Страница 7: ...at exchanger Leakage of refrigerant Refrigerant system is blocked None Improve heat radiation at outdoor heat exchanger Locate and repair leak Flush refrigeration cycle Under 14 C 25 2 F Higher than s...

Страница 8: ...ion Leakage of refrigerant or refrigeration system is blocked Set it lower or higher Close Vent door Clean or replace Air Filter Consider building an AWNING Remove obstacles or reinstall unit Clean th...

Страница 9: ...tilation door is closed and the air will be circulated inside the room and conditioned 7 1 1 3 Neon Lamp Indicator Neon Lamp Indicator The green neon light mounted above the control panel indicates co...

Страница 10: ...rmostat Control Knob as shown in Fig 4 Usually 6 7 is the recommended setting position Note When the Thermostat Control Knob is set to 10 moisture may freeze onto the evaporator fins and prevent effec...

Страница 11: ...he ventilation door is closed and the air will be circulated inside the room and conditioned 7 2 1 3 Neon Lamp Indicator Neon Lamp Indicator The green neon light mounted above the control panel indica...

Страница 12: ...the Thermostat Control Knob as shown in Fig 4 Usually 6 7 is the recommended setting position for cooling and 4 5 for heating Note When the Thermostat Control Knob is set to 10 moisture may freeze ont...

Страница 13: ...p in the fixed installation circuit Applicable for models without power supply plug only 8 1 2 Select the Best Location Install the unit at the nearest power outlet The air conditioner should be insta...

Страница 14: ...then secure it with wood screws or nails Note Tilt down for better drainage max 10 mm 8 3 4 Slide the Chassis back into the Cabinet 8 3 5 Lock the Chassis to the Cabinet reusing the Chassis Locking B...

Страница 15: ...r When performing the following steps do not pull the bottom edge of the Front Grille towards you more than 3 inches or you may damage the top tabs 2 Press inward on the Cabinet near the bottom right...

Страница 16: ...ndenser being corroded easily 1 Slide the Chassis out from the Cabinet 2 Remove the rubber plug from the Base Pan If any 3 Install the Drain Pan at the right corner of the Cabinet with 2 screws 4 Conn...

Страница 17: ...1 1 2 Mechanical Thermostat Heating 9 Technical Data 9 1 Thermostat Characteristics 9 1 1 CW A180ES CW A240ES 9 1 2 CW C180ES CW C240ES CW SC180ES 9 1 2 1 Mechanical Thermostat Cooling 17 CW C180ES C...

Страница 18: ...ng Characteristics Vs Outdoor Temperature 9 2 1 2 Heating Characteristics Vs Outdoor Temperature 9 2 2 2 Heating Characteristics Vs Outdoor Temperature 9 2 Operation Characteristics 9 2 1 CW A180ES 9...

Страница 19: ...ove the Front Intake Grille 2 Tilt up and pull out the Air Filter by the holder 3 Vacuum the front of the filter and then wash the back of it with water If it is badly soiled wash with a mild househol...

Страница 20: ...4 Remove the 2 knobs 5 Take off the Control Panel 6 Release the thermostat sensor from the sensor holder 7 Loosen the 3 screws of the Control Board 8 Slide the Control Board out from the chassis Contr...

Страница 21: ...ed View Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts 21 CW C180ES CW C240ES CW A180ES CW A240ES CW...

Страница 22: ...lve 1 CWB00003 CWB00003 220 Evaporator 1 CWB30C1064 CWB30C1063 CWB30C1076 300 Fan Motor 1 CWA951053 CWA951059 CWA951069 CWA951073 302 Capacitor Fan Motor 1 CWA312048 5 F 440VAC CWA312052 8 F 440VAC 30...

Страница 23: ...ied from MAICO Malaysia Vendor Code 061 E Filter Frame 716 and E Filter 717 is an optional part Supplied through sales route 23 CW C180ES CW C240ES CW A180ES CW A240ES CW SC180ES MAICO Printed in Mala...

Отзывы: