Panasonic CU-E18GFE-1 Скачать руководство пользователя страница 5

5

ENGLISH

ENGLISH

ENGLISH

ENGLISH

2

ON

1

OFF

SET

 

 and 

QUIET

 operations are available in all modes and 

could be cancelled by pressing the respective button again.

 

 and 

QUIET

 can not be selected at the same time.

•  When ON Timer is set, the unit may start earlier (up 

to 30 minutes) before the actual set time in order to 
achieve the temperature you preferred.

•  The timers repeat daily once set.
•  If there is a power failure, you can restore the 

previous setting (once power is resumed) by pressing 

the 

SET

 button.

•  If the timer is cancelled, press 

SET

 to restore the 

previous setting.

  The timer is based on the time set in the remote 

control.

  You can set your preferred time for ON and OFF 

timers.

QUIET

TO ENJOY QUIET ENVIRONMENT

•  This setting provides a quiet environment by 

reducing the air

fl

 ow noise.

TO SELECT FAN SPEED

•  There are 5 fan speeds, as well as 

automatic*.

  *  For automatic fan speed, the speed 

of the indoor fan is automatically 
adjusted according to the operation.

TO ACHIEVE TEMPERATURE QUICKLY

•  This setting enables the desired 

temperature to be reached quickly.

•  POWERFUL operation will run for 20 

minutes, after that this operation will stop 
automatically.

Select ON 

or OFF 

timer.

Set the 

desired 

time.

Con

fi

 rm 

the setting.

Hints

  Temperature setting of 1°C higher in cool mode or 

2°C lower in heat mode than the desired temperature 
performs a 10% power saving.

  To reduce power consumption during cool mode, close 

the curtains to prevent the sunlight and heat from 
coming in.

  To set either 12-hour (am/pm) or 24-hour time 

indication, press and hold 

CLOCK

 for approximately 10 

seconds.

To cancel ON or OFF timer, press 

ON

 or 

OFF

 , then press 

CANCEL

.

•  When you want the air conditioner to turn ON or OFF 

automatically at a preset time.

TO SET THE TIMER

FEATURE OPERATION

FEATURE OPERATION

FEATURE OPERATION

FEATURE OPERATION

TIMER SETTING

TIMER SETTING

TIMER SETTING

TIMER SETTING

  To turn off the air conditioner, press 

OFF/ON

.

AIR SWING

AUTO

AIR SWING

MANUAL

•  Keeps the room ventilated.
• AIR SWING - AUTO
  •  In heat mode, the air blows upwards 

for a while, then starts to blow 
horizontally.

  •  The vertical air

fl

 ow louver swings up 

and down automatically.

•  AIR SWING - MANUAL
 • The 

air

fl

 ow direction can be adjusted 

as desired by using remote control.

•  Do not adjust the vertical air

fl

 ow 

direction louvers by hand.

•  Both upper and lower horizontal 

air

fl

 ow direction louvers are manually 

adjustable.

TO ADJUST AIRFLOW DIRECTION

Содержание CU-E18GFE-1

Страница 1: ...τις για μελλοντική αναφορά Manufactured by Panasonic HA Air Conditioning M Sdn Bhd Lot 2 Persiaran Tengku Ampuan Section 21 Shah Alam Industrial Site 40300 Shah Alam Selangor Malaysia 2006 Panasonic HA Air Conditioning M Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law M at su sh ita El ec tr ic In du st ria l Co Lt d We b Site http w ww pa nas oni c ...

Страница 2: ...t an authorized dealer or specialist for the installation work During Operation Do not insert your fingers or other objects into the indoor or outdoor unit Do not attempt to repair the unit by yourself Indoor Unit During Installation Do not install the unit in a potentially explosive atmosphere Ensure that the drainage pipe is connected properly Otherwise leakage may occur During Operation Do not ...

Страница 3: ...ore information Penalties may also be applicable for incorrect disposal of waste products in accordance with national legislation subject to the national law of each member state Information on Disposal in other countries outside the European Union This symbol is only valid in the European Union If you wish to discard this product please contact your installer dealer or local authority and ask for...

Страница 4: ...ON REMOTE CONTROL PREPARATION REMOTE CONTROL PREPARATION REMOTE CONTROL PREPARATION MODE OPERATION MODE OPERATION MODE OPERATION MODE OPERATION AUTO HEAT DRY COOL INDICATOR INDICATOR INDICATOR INDICATOR Unit selects the operation mode according to temperature setting outdoor and room temperature Operation mode is reselected every 30 minutes During initial operation mode selection the power indicat...

Страница 5: ...0 minutes after that this operation will stop automatically Select ON or OFF timer Set the desired time Confirm the setting Hints Temperature setting of 1 C higher in cool mode or 2 C lower in heat mode than the desired temperature performs a 10 power saving To reduce power consumption during cool mode close the curtains to prevent the sunlight and heat from coming in To set either 12 hour am pm o...

Страница 6: ... gently with a soft dry cloth To select preferred airflow pattern Selection Pattern Description This setting blows air from upper outlet only This setting automatically decides airflow pattern depending on mode and conditions Default and recommended For Heat mode during start or low discharge temperature For Cool mode when setting temperature is achieved the air is blown from the upper air outlet ...

Страница 7: ...let and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the front panel properly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Check if timers have been set Check the following before calling for servicing...

Страница 8: ...etenga el funcionamiento Ligue Desligue a unidade Ξεκινήστε σταµατήστε τη λειτουργία Select the desired mode Seleccione el modo deseado Seleccione o modo de funcionamento pretendido Επιλέξτε την κατάσταση λειτουργίας που επιθυµείτε Select fan speed Seleccione la velocidad del ventilador Seleccione a velocidade do ventilador Επιλογή ταχύτητας ανεμιστήρα Adjust the airflow direction louver Ajuste la...

Отзывы: