40
12.2.4 Connect the Cable to the Indoor Unit
The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.
1 Install the indoor unit on the installing holder that mounted on the wall.
2 Open the front panel and grille door by loosening the screw.
3 Cable connection to the power supply through Isolating Devices (Disconnecting means).
o
Connect the approved polychloroprene sheathed
power supply cord
3 x 1.5 mm
2
(1.0 ~ 1.5HP) or 3 x
2.5 mm
2
(2.0 ~ 2.25HP), type designation 60245 IEC 57 or heavier cord to the terminal board, and
connect the other end of the cable to Isolating Devices (Disconnecting means).
o
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or
otherwise) is too short.
o
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air
conditioner shall be done by using approved socket and plug rated 15/16A (1.0 ~ 1.5HP) or 16A (2.0 ~
2.25HP). Wiring work to both socket and plug must follow to national wiring standard.
4 Bind all the
power supply cord
lead wire with tape and route the power supply cord via the left escapement.
5
Connection cable
between indoor unit and outdoor unit shall be approved polychloroprene sheathed
4 × 1.5 mm
2
(1.0 ~ 1.5HP) or 4 × 2.5 mm
2
(2.0 ~ 2.25HP) flexible cord, type designation 60245 IEC 57 or
heavier cord.
6 Bind all the indoor and outdoor
Connection cable
with tape and route the connection cable via the right
escapement.
7 Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor
unit according to the diagram below.
•
How to pull the piping and drain hose out, in case of the
embedded piping.
•
In case of left piping how to insert the
connection cable and drain hose.
Adjust the piping slightly
downwards.
Change the drain hose position
(For the right piping, follow the same
procedure)
Rear view for left piping installation
Drain cap
Drain hose
PIPE
HOLE
CENTER
115mm TO
HOLE CENTER
Drain hose
Connection cable
Sleeve for piping hole
Drain hose
Piping
Connection cable
More than 950 mm
Cable
45
°
Drain hose
Piping
PVC tube for
drain hose
Indoor unit
55 mm
Piping
Cable
Apply putty or caulking
material to seal the wall
opening.
Connection
cable
Piping
More
than
470 m
m
More
tha
n
950
mm
PVC tube (VP-65) for piping
and connection cable
M
or
e than 700 m
m
Drain hose
from main unit
PVC tube for drain hose (VP-30)
PVC tube for
drain hose (VP-20)