OPTIMUM OPERATION

Observe the following precautions to ensure the system operates
properly.

Adjust the air outlet properly and avoid direct air flow to room
inhabitants.

Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.

Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.

Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease
in the cooling or heating effect.

Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop the operation.

Turn off the main power supply switch to the unit when the unit
is not used for longer periods of time. If the switch is on, it uses
electricity. Before restarting the unit, turn on the main power
supply switch 6 hours before operation to ensure smooth
running. (Refer to the chapter “Maintenance” in the indoor unit
manual)

When the display shows 

 (time to clean the air filter), ask a

qualified service person to clean the filters. (Refer to the chapter
“Maintenance” in the indoor unit manual)

FOLLOWING SYMPTOMS ARE NOT AIR
CONDITIONER TROUBLES

THE SYSTEM DOES NOT OPERATE

The air conditioner does not start immediately after the ON/
OFF button on the remote controller is pushed.
If the operation lamp lights, the system is in normal condition.
To prevent overloading of the compressor motor, the air
conditioner starts 5 minutes after it is turned ON again in case it
was turned OFF just before. The same starting delay occurs
after the operation mode selector button was used.

The system does not start immediately after the power
supply is turned on.
Wait one minute until the micro computer is prepared for
operation.

COOL/HEAT CANNOT BE CHANGED OVER

When the display shows 

 (changeover under

control), it shows that this is a slave remote controller.

When the cool/heat changeover remote control switch is
installed and the display shows 

 (changeover under

control).
This is because cool/heat changeover is controlled by the cool/
heat changeover remote control switch. Ask your Panasonic
dealer where the remote control switch is installed.

WHITE MIST COMES OUT OF A UNIT

Indoor unit

When humidity is high during cooling operation
If the interior of an indoor unit is extremely contaminated, the
temperature distribution inside a room becomes uneven. It is
necessary to clean the interior of the indoor unit. Ask your
Panasonic dealer for details on cleaning the unit. This operation
requires a qualified service person.

Immediately after the cooling operation stops and if the
room temperature and humidity are low
This is because warm refrigerant gas flows back into the indoor
unit and generates steam.

Indoor unit, outdoor unit

When the system is changed over to heating operation after
defrost operation
Moisture generated by defrost becomes steam and is
exhausted.

NOISE OF AIR CONDITIONERS

Indoor unit

A “zeen” sound is heard immediately after the power
supply is turned on.
The electronic expansion valve inside an indoor unit starts
working and makes the noise. Its volume will reduce in about
one minute.

A continuous low “shah” sound is heard when the system
is in cooling operation or at a stop
When the drain pump (optional accessories) is in operation, this
noise is heard.

A “pishi-pishi” squeaking sound is heard when the system
stops after heating operation.
Expansion and contraction of plastic parts caused by
temperature change make this noise.

A low “sah”, “choro-choro” sound is heard while the indoor
unit is stopped.
When the other indoor unit is in operation, this noise is heard.
In order to prevent oil and refrigerant from remaining in the
system, a small amount of refrigerant is kept flowing.

Indoor unit, outdoor unit

A continuous low hissing sound is heard when the system
is in cooling or defrost operation.
This is the sound of refrigerant gas flowing through both indoor
and outdoor units.

A hissing sound which is heard at the start or immediately
after stopping operation or defrost operation
This is the noise of refrigerant caused by flow stop or flow
change.

Outdoor unit

When the tone of operating noise changes
This noise is caused by the change of frequency.

THE UNITS CAN GIVE OFF ODOURS

The unit can absorb the smell of rooms, furniture, cigarettes,
etc., and then emit it again.

THE DISPLAY SHOWS 

.

This is the case immediately after the main power supply
switch is turned on and means that the remote controller is
in normal condition. This continues for one minute.

THE COMPRESSOR IN THE OUTDOOR UNIT DOES NOT
STOP AFTER A SHORT HEATING OPERATION

This is to prevent oil and refrigerant from remaining in the
compressor. The unit will stop after 5 to 10 minutes.

THE INSIDE OF AN OUTDOOR UNIT IS WARM EVEN
WHEN THE UNIT HAS STOPPED

This is because the crankcase heater is warming the
compressor so that the compressor can start smoothly.

3VA11387-2A̲Eng

01.10.9, 7:54 PM

Page 5

Adobe PageMaker 6.5J/PPC

Содержание CU-8ME1XPA

Страница 1: ...SPAÑOL ITALIANO E HNIKA NEDERLANDS PORTUGUES OPERATION MANUAL Model No Urban Multi Heat recovery inverter series CU 8ME1XPA CU 10ME1XPA PACKAGED AIR CONDITIONER Before operating this set please read these instructions completely ...

Страница 2: ...le to changeover heat cool with the remote controller when this icon is displayed 4 Display air flow flap Refer to the chapter Operation procedure Adjusting the air flow direction 5 Display ventilation air cleaning This display shows that the total heat exchange and the air cleaning unit are in operation these are optional accessories 6 Display set temperature This display shows the temperature yo...

Страница 3: ...ller with a hard pointed object The remote controller may be damaged Never pull or twist the electric wire of the remote controller It may cause the unit to malfunction Never inspect or service the unit by yourself Ask a qualified service person to perform this work To prevent refrigerant leak contact your Panasonic dealer When the system is installed and run in a small room it is required to keep...

Страница 4: ...pability decreases and the system goes into defrost operation The indoor unit fan stops and the remote controller displays After maximum 10 minutes of defrost operation the system returns to heating operation again Hot start heatpump types only In order to prevent cold air from blowing out of an indoor unit at the start of heating operation the indoor fan is automatically stopped The display of th...

Страница 5: ...gnated as the master remote controller and the display showing changeover under control vanishes The displays of other remote controllers show changeover under control PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller controls one indoor unit system Confirm the following if you...

Страница 6: ...rature distribution inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your Panasonic dealer for details on cleaning the unit This operation requires a qualified service person Immediately after the cooling operation stops and if the room temperature and humidity are low This is because warm refrigerant gas flows back into the indoor unit and generates steam ...

Страница 7: ...utomatically restarts immediately after the power supply is recovered Check if no fuse has blown or breaker has worked Change the fuse or reset the breaker if necessary 2 If the system goes into fan only operation but as soon as it goes into heating or cooling operation the system stops Check if air inlet or outlet of outdoor or indoor unit is not blocked by obstacles Remove any obstacle and make ...

Страница 8: ...3VA11387 2A EM01A146 0110 HT Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global ...

Отзывы: