- 17 -
Press the Power Button on the Remote Control to select the Serviceman Adjustment
For Adjustments:
1.Press Channel Up/Down on the
Remote Control to select one of
the available Service Adjustments
(See a in Fig. 13).
Note: Write Down the original
value set (b in Fig. 13) for
each address before
modifying anything. It is
easy to erroneously adjust
the wrong item.
2.Press Volume Up/Down on the
Remote Control to adjust the
level of the selected Service
Adjustment (See b in Fig. 13).
CH
CH
PW
To B Items.
IMPORTANT NOTE:
Always Exit the Serviceman
Mode Following Adjustments.
Options Adjustment
Adj. Range
Default
Level
S0
PIP COLOR
0 ~ 127
80
S1
PIP CONTRAST
0 ~ 127
52
S2
UP 1/9
0 ~ 255
26
S3
DOWN 1/9
0 ~ 255
146
S4
LEFT 1/9
0 ~ 255
9
S5
RIGH 1/9
0 ~ 255
103
S6
UP 1/16
0 ~ 255
27
S7
DOWN 1/16
0 ~ 255
163
S8
LEFT 1/16
0 ~ 255
9
S9
RIGH 1/16
0 ~ 255
118
Sa
FREERUN
N/A
N/A
Sb
CLOCK ADJUSTMENT
0 ~ 255
128
Sc
PIP TINT
0 ~ 63
50
Sd
LOUDNESS
COMPENSATION
0 ~ 63
2
MTS Adjustment
Adj. Range
Default
Level
M0
INPUT LEVEL
0 ~ 63
31
M1
HIGH-LEVEL SEPARATION
0 ~ 63
31
M2
LOW-LEVEL SEPARATION
0 ~ 31
31
PW