Panasonic CS-Z12RKR Скачать руководство пользователя страница 7

English

7

See "To learn more..." for details.

How to use

ECONAVI

To optimise energy saving

NANOE-G

To purify the air

NANOE-G

• nanoe-G starts automatically when the unit is turned 

on with 

OFF/ON

 or timer ON is activated.

• Can be activated even when the unit is turned off. In 

this condition, the unit will operate as a fan with AUTO 

fan speed and 

fl

 ap swing.

To deactivate viruses/bacteria on the fi lter

NANOE-G

POWER

• After the unit is turned off, the nanoe-G in-

fi

 lter 

deactivation may activate up to 150 minutes. Turning 

on the unit cancels this operation.

• To disable this operation in the future, press and hold 

NANOE-G

 until a short beep sound is heard. This will not 

disable the nanoe-G to purify the air.

• To restore the nanoe-G in-

fi

 lter deactivation, press and 

hold 

NANOE-G

 until a long beep sound is heard. 

AIR SWING

To adjust airfl ow direction

(Remote control display)

• Keeps the room ventilated.

• In COOL/DRY mode, if AUTO is set, the 

fl

 aps swings 

left/right and up/down automatically.

• In HEAT mode, if AUTO is set, the horizontal 

fl

 ap is 

fi

 xed at the predetermined position. The vertical 

fl

 ap 

swings left/right after the temperature rises.

• In i AUTO-X mode, if AUTO is set, the horizontal 

fl

 ap 

is 

fi

 xed at the lower position and shift to the upper 

position after reaches set temperature. The vertical 

fl

 ap movement depends on human activity sensor. 

• If manual is set, the horizontal and vertical 

fl

 ap are 

fi

 xed at the predetermined position.

• Do not adjust the 

fl

 ap by hand.

To set the timer

2 sets of ON and OFF timers are available 
to turn ON or OFF the unit at different preset 
times.

ON

OFF

SET

CANCEL

1

2

3

TIMER

CANCEL

3

TIMER

1

2

3

1

Select ON or OFF 
timer

Example: 
OFF at 22:00

• Each time pressed:

OFF

Cancel

2

Set the time

2

3

Confi rm

SET

TIMER

• To cancel ON or OFF timer, press 

ON

 or 

OFF

 

to select respective   or   then press 

CANCEL

.

• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 
pressing 

ON

 or 

OFF

 to select respective   or 

 then press 

SET

.

• The nearest timer setting will be displayed and 

will activate in sequence.

• When ON Timer is set, the unit may start 

earlier (up to 35 minutes) before the actual 
set time in order to achieve the desired 
temperature on time.

• Timer operation is based on the clock set in 

the remote control and repeats daily once set. 
For clock setting, please refer to Quick guide.

Note

ECONAVI

 , 

POWERFUL/QUIET

  , 

NANOE-G

• Can be activated in HEAT, COOL and DRY 

mode and can be cancelled by pressing the 
respective button again.

i AUTO-X

 , 

ECONAVI

 , 

POWERFUL/QUIET

• Cannot be selected at the same time.
• Cannot be activated during MILD DRY.

Auto Restart Control

• If power is resumed after a power failure, the 

operation will restart automatically after a period 
of time with previous operation mode and air

fl

 ow 

direction. 

• This control is not applicable when TIMER is set.

F570018-SA0815-1.indb   7

F570018-SA0815-1.indb   7

17/08/2015   2:42:49 PM

17/08/2015   2:42:49 PM

Process Black

Process Black

Содержание CS-Z12RKR

Страница 1: ...unit read these operating instructions thoroughly and keep them for future reference English Model No Indoor Unit Outdoor Unit CS Z7RKR CS Z9RKR CS Z12RKR CS Z15RKR CS Z18RKR CS Z21RKR CS Z24RKR CS Z28RKR CU Z7RKR CU Z9RKR CU Z12RKR CU Z15RKR CU Z18RKR CU Z21RKR CU Z24RKR CU Z28RKR Operating Instructions Air Conditioner F570018 i AUTO X POWERFUL ...

Страница 2: ... you get to enjoy instant fast cooling satisfaction on a hot day and cooling comfort that goes on all day long Applicable for horizontal flap AUTO setting ECONAVI INVERTER The Perfect Energy Saving Technology ECONAVI detects where energy is normally wasted and adjusts cooling heating power depending on room conditions and activity levels Then INVERTER leverages ECONAVI sensor data and varies compr...

Страница 3: ... C DRY 1 C 2 C lower than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control within 8 m from the remote control receiver of the indoor unit The illustrations in this manual are for explanation purposes only and may differ from the actual unit They are subject to change without notice for future improvement Table of contents Safety pre...

Страница 4: ...nstallation Instruction table Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock ...

Страница 5: ...rvicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment...

Страница 6: ...te room cooling Set temperature i AUTO X 1 C Max 4 hours After max 4 hours the set temperature is shifted according to activity detection Fan speed is fixed at AUTO fan speed selection is prohibited During unit is off press i AUTO X will turn on the unit with i AUTO X mode i AUTO X mode can be cancelled by pressing the respective button again MODE To select operation mode AUTO For your convenience...

Страница 7: ...nt depends on human activity sensor If manual is set the horizontal and vertical flap are fixed at the predetermined position Do not adjust the flap by hand To set the timer 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset times ON OFF SET CANCEL 1 2 3 TIMER CANCEL 3 TIMER 1 2 3 1 Select ON or OFF timer Example OFF at 22 00 Each time pressed OFF Cancel 2 Set...

Страница 8: ... ECONAVI Note AIR SWING When manual AIR SWING is selected the ECONAVI operations will be cancelled The unit will start to initialise for approximately 1 minute The human activity sensor and the sunlight sensor will start to detect Human activity sensor operation Low activity Normal activity Human Mode Set temperature High activity Absent ECONAVI Detecting human presence and activity the unit contr...

Страница 9: ...t as non heat source movement if a human stays motionless for certain period of time Do not place large objects near the sensor and keep away heating units or humidifier from the sensor s detection area They may cause sensor malfunction i AUTO X Low activity Normal activity Human Mode Set temperature High activity Absent i AUTO X Fast cooling to maximum of 4 hours the unit continue to provide cool...

Страница 10: ...2 Close down 3 Press both ends of the front panel 4 For CS Z18RKR CS Z21RKR CS Z24RKR CS Z28RKR Press at center of the front panel nanoe G Generator Every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Every 2 weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Rep...

Страница 11: ...ave collected around the front panel grilles and wall surrounding the unit after extended use The dust accumulation is due to air purification effect of negative ions from nanoe G Remove the dust regularly with a clean dampened cloth Check the following before calling for servicing Symptom Check Operation in HEAT COOL mode is not working efficiently Set the temperature correctly Close all doors an...

Страница 12: ... in other Countries outside the European Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by t...

Отзывы: