SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER 

NAMES OF THE PARTS

INDOOR UNIT DISPLAY

OPERATING INSTRUCTIONS

PROTECTION

INSTALLATION 

MAINTENANCE

TROUBLESHOOTING

EMERGENCY FUNCTION & AUTO-RESTART FUNCTION

REMOTE CONTROL

 ......................1

........................................................................................................5

.........................................................................................................6

..............................................7

...............................................................................................................8

..............................................................................................12

.........................................................................................................................19

.....................................................................................................................20

....................................................................................................................29

..........................................................................................................30

CONTENTS

Содержание CS-YE12WKU1

Страница 1: ...CS YE9WKU1 CS YE12WKU1 CU YE9WKU1 CU YE12WKU1 ...

Страница 2: ......

Страница 3: ...ATIONS FOR THE INSTALLER NAMES OF THE PARTS INDOOR UNIT DISPLAY OPERATING INSTRUCTIONS PROTECTION INSTALLATION MAINTENANCE TROUBLESHOOTING EMERGENCY FUNCTION AUTO RESTART FUNCTION REMOTE CONTROL 1 5 6 7 8 12 19 20 29 30 CONTENTS ...

Страница 4: ...should be forbidden to children Unforeseeable accidents could happen Make sure that the base of the outdoor unit is firmly fixed Check that air cannot enter the refrigerant system and check for refrigerant leaks when moving the air conditioner The ratings of the fuse installed in the built in control unit are T 5A 250V The user must protect the indoor unit with a fuse of suitable capacity for the ...

Страница 5: ...d in accordance with the requirements of NEC and CEC by authorized personnel only This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall no...

Страница 6: ...ce an authorized service Center authorized Service Center This appliance has been made for air conditioning domestic environments and must not be used for any other purpose such as for drying clothes cooling food etc Always use the appliance with the air filter mounted The use of the conditioner without air filter could cause an excessive accumulation of dust or waste on the inner parts of the dev...

Страница 7: ...ed physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Do not climb onto or place any heavy or hot objects on top of the appliance Do not leave windows or doors open when the air conditioner is operating Do not direct the airflow onto plants or ani...

Страница 8: ...unit rating label WALL AIR CONDITIONER The is made up of two or more units connected between themselves through copper pipes properly insulated and an electrical connecting cable air conditioner The indoor unit is installed on the walls of the room to be conditioned The outdoor unit is installed on the floor or on the wall on suitable brackets Technical data of the air conditioner are printed on t...

Страница 9: ...lay of the remote controller but on the indoor display 4 2 O 1 2 5 3 4 1 2 3 4 5 3 1 2 3 5 4 No Led Function POWER This symbol appears when the unit is power on 1 2 3 4 5 Temperature display if present Error code 1 Lights up during Timer operation when the air conditioner is operational 2 Displays the malfunction code when fault occurs SLEEP mode Lights up during Timer operation The symbol appears...

Страница 10: ...s the unit will change to HEATmode Press again after 5 seconds the unit will turn off If the remote controller fails to work or maintenance necessary proceed as following 7 EMERGENCY FUNCTION AUTO RESTART FUNCTION The appliance is preset with an auto restart function In case of a sudden power failure the module will memorizes the setting conditions before the power failure When the power restores ...

Страница 11: ...rbo 1 2 3 4 Fan 5 No Button Function Press this button to activate deactivate the ECO function Eco To set the automatic switch on off time Timer To switch on off of the function SLEEP Sleep 10 To switch on off of the LED display Display To switch on off of the auto swing function of deflectors Swing 12 To switch on off of the Mute function Mute 13 To switch on off of the follow me function I Feel ...

Страница 12: ... of buttons and indicators may vary according to the model but their function is the same The display and some functions of the remote control may vary according to the model The unit confirms the correct reception of each button with a beep ...

Страница 13: ...ndicator Auto low mid high 13 SUPER indicator 14 15 Mute indicator 16 Up down auto swing indicator 17 Temperature indicator Meaning No Symbols Left right auto swing indicator SLEEP function indicator Timer indicator Battery indicator Mode Auto function indicator Health function indicator I FEEL functions indicator ECO indicator The display and some functions of the remote control may vary accordin...

Страница 14: ... damage when not using for a long time Signal receptor For some model each time when insert the batteries in the remote controller for the first time you need to set the Cooling only or Heating pump control type As soon as you insert the batteries the symbols and start flashing operate as below 1 When the is displayed push any button to set the Cooling only type remote controller 2 When the is dis...

Страница 15: ...up to down Press again to stop the swing movement at the current angle 2 Press to active the vertical deflectors to swing from left to right Press again to stop the swing movement at the current angle 2 If the vertical deflectors are positioned manually which placed under the flaps they allow to move the air flow direct to rightward or leftward Filter Heat Fan The direction of the air outlet is mo...

Страница 16: ...With the button or set a temperature lower than that of the room To activate the heating function HEAT press the MODE button until the symbol appears on the display With the button or set a temperature higher than that of the room In HEATING operation the appliance can automatically activate a defrost cycle which is essential to clean the frost on the condenser so as to recover its heat exchange f...

Страница 17: ...de Press MODE until appears in the display An automatic function of pre setting is activated FAN Fan mode air ventilation only To set the FAN mode press MODE until appears on the display AUTO MODE Automatic mode AUTO To set theAUTO mode press MODE until appears on the display In AUTO mode the run mode will be set automatically according to the room temperature ...

Страница 18: ...LED display SLEEP Pre setting automatic operating program After 10 hours running in sleep mode the air conditioner will change to the previous setting mode Press SLEEP button to activate the SLEEP function and appears on the display Press again to cancel this function FAN function FAN button FAN Change the operating fan speed Press FAN button to set the running fan speed it can be set to AUTO LOW ...

Страница 19: ...nce will run in ECO mode Press again to cancel it NOTE The ECO function is available in both COOLING and HEATING modes Turbo function TURBO To activate turbo function press the TURBO button and will appear on the display In COOL HEATmode when you select TURBO feature the appliance will operate the highest fan setting to blow the strong airflow Press again to cancel this function ...

Страница 20: ...Dry by press the MODE button And set the needed fan speed by press FAN button And press or to set the needed operation temperature 3 Press TIMER button at the second time to set the switch on Press or to set the needed timer 4 Press TIMER button at the third time to confirm CANCEL it by press TIMER button When the unit is switch on you can set the TIMER OFF To set the time of automatic switch off ...

Страница 21: ...ar on the remote display Do it again to deactivate this function This function enables the remote control to measure the temperature at its current location and send this signal to the air conditioner to optimize the temperature around you and ensure the comfort It will automatically deactivate 2 hours later Indoor unit Outdoor unit Temp 86 30 41 5 Temp 86 30 To active this function press and butt...

Страница 22: ...e mode during operation the system does not restart immediately until after 3 minutes protection function for the compressor MODEL Temperature Cooling operating Heatling operating Drying operating Room Temperature Outdoor Temperature 17 32 63 89 15 53 59 127 15 53 5 127 For models with low temperature cooling system 0 30 32 86 17 32 63 89 25 30 13 86 15 53 59 127 ...

Страница 23: ...f necessary that should not interfere with the air flow Leave space as shown in the picture for the air to circulate freely Install the outdoor unit in a safe and solid place If the outdoor unit is subject to vibration place rubber gaskets onto the feet of the unit water drain pipe Minimum space to be left showing in the picture Outdoor unit Indoor unit Pipe length is 50 Max be less than 16 40 ft ...

Страница 24: ...ole must slope downwards towards the exterior Note The shape of the mounting plate may be different from the one above but installation method is similar Indoors Outdoors 1 Lift the front panel 2 Take off the cover as indicated in the by removing a screw or by breaking the hooks 3 For the electrical connections see the circuit diagram on the right part of the unit under the front panel 4 Connect t...

Страница 25: ...to create siphons 2 The drain hose must slant downwards to aid drainage 3 Do not bend the drain hose or leave it protruding or twisted and do not put the end of it in water If an extension is connected to the drain hose ensure that it is lagged when it passes into the indoor unit 4 If the piping is installed to the right the pipes power cable and drain hose must be lagged and secured onto the rear...

Страница 26: ...t should be installed on a solid wall and fastened securely The following procedure must be observed before co nnecting the pipes and connecting cables decide which is the best position on the wall and leave enough space to be able to carry out maintenance easily Fasten the support to the wall using screw anchors which are particularly suited to the type of wall Use a larger quantity of screw anch...

Страница 27: ...xcessive tightening torque there will also be some leakage as the flange could be damaged 3 The surest system consists in tightening the connecti on by using a fix wrench and a torque wrench in this case use the table on page 24 ELECTRICAL CONNECTIONS CONNECTING THE PIPES tap 1 Remove the handle on the right side plate of outdoor unit 2 Connect the power connection cord to the terminal board Wirin...

Страница 28: ...BLEEDING Wrap applying correctly correctly correctly correctly 25 INSTALLATION MANUAL Installation of the outdoor unit INSTALLATION MANUAL operation test ...

Страница 29: ...83 33 21 55 35 59 04 Service port nut Protection caps 5 17 6 64 18 45 22 14 wrist strength arm strength arm strength arm strength MODEL capacity Btu h 9K 12K Liquid pipe diameter Gas pipe diameter Length of pipe with standard charge Maximum distance between indoor and outdoor unit Max diff in level between indoor and outdoor unit Type of refrigerant 1 1 4 6 1 4 6 3 8 9 52 3 8 9 52 24 61 ft 24 61 f...

Страница 30: ...ifferent models the wiring diagram may be different Please refer to the wiring diagrams indoor unit and outdoor unit respectively On the indoor unit the wiring diagram is l under the front panel On the outdoor unit the wiring diagram is l on the backside of the outdoor handle cover affixed to the ocated ocated Front panel Wiring diagram Wiring diagram Outdoor handle cover 27 ...

Страница 31: ... 3 L 2 N 1 S N L2 L L1 sectional area INVERTER TYPE MODEL capacity Btu h 110V 9K 12K air conditioner indoor unit fuse parameter is 50T 3 15A 125V 9K 12K air conditioner outdoor unit fuse parameter is 61T 15A 9K 115V 12K 115V AWG 16 AWG 16 2 3 0mm 2 3 0mm 2 3 0mm AWG12 AWG12 2 3 0mm 2 3 0mm 2 3 0mm AWG12 AWG12 AWG12 AWG12 ...

Страница 32: ...the hinges to make the cleaning easier 2 Clean the indoor unit using a cloth with water not higher than 104 40 and neutral soap Never use aggressive solvents or detergents 3 remove by lifting up and If the battery of the outdoor unit is clogged remove any leaves or waste by hand and remove the dust with an air jet or a bit of water END OF SEASON MAINTENANCE 1 Disconnect the automatic switch or the...

Страница 33: ...e and does not indicate a problem Unsuitable temperature setting Obstructed air conditioner intakes and outlets Dirty air filter Fan speed set at minimum Other sources of heat in the room No refrigerant Remote control is not close enough to indoor unit The batteries of remote control need to be replaced Obstacles between remote control and signal receiver in indoor unit Display function inactive P...

Страница 34: ...adio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by tuming the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Incr...