![Panasonic CS-XE12WKUAW Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/panasonic/cs-xe12wkuaw/cs-xe12wkuaw_service-manual_1508223068.webp)
68
OD Pipe Temperature
A 78.8°F
(26°C)
B 91.4°F
(33°C)
During above condition, when indoor heat exchanger temperature is below 41°F (5°C), the outdoor fan will stop
according to outdoor piping temperature as following:
13.4 Airflow Direction
There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by
vertical vanes).
Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat
exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using
remote control).
13.4.1 Vertical
Airflow
13.4.1.1 CS-XE9WKUAW CS-XE12WKUAW CS-XE15WKUAW
Operation Mode
Airflow Direction
Upper Vane Angle (°)
Lower Vane Angle (°)
1 2 3 4 5 1 2 3 4 5
Heating
Auto with Heat
Exchanger
Temperature
A 67
63
B 95
92
C 67
63
Manual
67 83 88 95 110 63 75 85 92 105
Cooling and Fan
Auto
65 ~ 115
58 ~ 100
Manual
65 67 94 100 115 58 63 70 80 100
Soft Dry
Auto
65 ~ 115
58 ~ 100
Manual
65 67 94 100 115 58 63 70 80 100
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner is
stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
OD Pipe Temp.
Outdoor
fan OFF
Outdoor
fan ON
86°F (30°C)
122.0°F (50°C)
Upper vane: 60°
Lower vane: 58°
86.0°F (30°C)
C
B
A
Indoor Heat
Exchanger Temperature
Closed Position
Figure 1
96.8°F (36°C)
136.4°F (58°C)
Figure 2
Step 3
Step 2
Step 1
Reference point
Step 4
Step 5