background image

ENGLISH

7

NOTES

NOTES

NANOE-G

 , 

POWERFUL/

QUIET

 , 

ECONAVI /
A.COMFORT

POWERFUL/

QUIET

 , 

ECONAVI /
A.COMFORT

•  Can be activated in all modes and can be cancelled by 

pressing the respective button again.

•  Cannot be selected at the same time.

8

TO MONITOR HUMAN PRESENCE & ACTIVITY 

FOR ENERGY SAVING & COMFORT

A.COMFORT

ECONAVI

A.COMFORT

ECONAVI

NORMAL

ECONAVI

To optimize energy 

saving

ECONAVI

A.COMFORT

To maximize comfort

AUTO COMFORT

Set Fan Speed

-2°C

-1°C

HEAT Mode

Set Temperature

+0.3°C

Heat Source & Movement

Normal

High

Low

None

Set Fan Speed

 Medium

Fan

+1 tap*

+2°C

-1°C

+1 tap

+0.3°C

COOL/DRY Mode

Set Temperature

* For first 15 minutes or until set temperature is reached.

•  The human activity sensor may not detect moving objects 

further than 7m away or beyond detection angle.

•  The human activity sensor sensitivity is infl uenced by 

indoor unit location, movement speed, temperature range, 

etc.

•  The human activity sensor may mistakenly detect pets, 

certain lighting, fl uttering curtains and light refl ection as 

human being.

5

TO ADJUST VERTICAL AIRFLOW DIRECTION 

(5 OPTIONS)

AIR SWING

•  Keeps the room ventilated.

•  In COOL/DRY mode, if AUTO is set, the louver swing 

up/down automatically.

•  In HEAT mode, if AUTO is set, the louver fi x at 

predetermined position.

6

TO PURIFY THE AIR

NANOE-G

•  Removes/deactivates harmful micro-organisms such as 

viruses, bacteria, etc.

•  Can be activated even when the unit is turned off. In this 

condition, fan speed and air swing cannot be adjusted.

•  nanoe-G starts automatically with the unit switched on 

with 

OFF/ON

.

7

TO SWITCH BETWEEN POWERFUL & QUIET

POWERFUL/

QUIET

QUIET

POWERFUL

NORMAL

POWERFUL

TO REACH TEMPERATURE 

QUICKLY

POWERFUL

•  This operation will stop automatically after 20 

minutes.

QUIET

TO ENJOY QUIET 

OPERATION

QUIET

•  This operation reduces airfl ow noises.

Содержание CS-W7NKD

Страница 1: ...CS W9NKD CU W9NKD CS W12NKD CU W12NKD F568364 Panasonic HA Air Conditioning M Sdn Bhd 2011 Unauthorized copying and distribution is a violation of law ENGLISH Before operating the unit read these ope...

Страница 2: ...BT Dry bulb temperature WBT Wet bulb temperature DBT WBT DBT WBT COOLING Max 32 23 43 26 Min 16 11 16 11 HEATING Max 30 24 18 Min 16 5 6 C DBT WBT DBT WBT DBT WBT 32 23 43 26 16 11 16 11 30 24 18 16 5...

Страница 3: ...ause leakage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst...

Страница 4: ...t Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow ou...

Страница 5: ...oom temperature Once auto mode is selected the unit will operate at the standard setting temperature Room temperature Operation mode Standard setting temperature 23 C above Cool 25 C Below 23 C Dry 22...

Страница 6: ...nsor sensitivity is influenced by indoor unit location movement speed temperature range etc The human activity sensor may mistakenly detect pets certain lighting fluttering curtains and light reflecti...

Страница 7: ...timer Set the time Confirm To cancel ON or OFF timer press ON or OFF then press CANCEL When ON Timer is set the unit may start earlier up to 30 minutes before the actual set time in order to achieve...

Страница 8: ...4 9 5 6 7 3 10 nanoe G GENERATOR Do not touch during operation 1 INDOOR UNIT Wipe the unit gently with a soft dry cloth 2 FRONT PANEL Remove Front Panel Raise and pull to remove the front panel Wash...

Страница 9: ...is drained from the outdoor unit Indoor fan stops occasionally during heating operation To avoid unintended cooling effect Cracking sound during operation Changes of temperature caused the expansion c...

Страница 10: ...ealer under the following conditions Abnormal noise during operation Water foreign particles have entered the remote control Water leaks from Indoor unit Circuit breaker switches off frequently Power...

Страница 11: ...on the Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment TR on RoHS The content of hazardous substance with the exemption of the applications listed in the...

Отзывы: