Panasonic CS-W12DKR Скачать руководство пользователя страница 2

QUIET POWERFUL ION

TIMER

POWER

CANCEL

OFF

TIMER

ON

TIMER

FAN

SPEED

AIR

SWING

AUTO

DRY

COOL

MODE

TIMER

ON

1

2

3

OFF

CLOCK

RESET

SET

CANCEL

TEMP

POWERFUL

FAN SPEED

AIR SWING

OFF/ON

Q UIET

QUIET POWERFUL ION

SUPER

A LLERU-B USTER

TIMER

POWER

Air intake

Airflow direction louver

Ionizer

Air filter

Front panel

Indoor Unit

Outdoor Unit

Air inlet 

(rear)

Air outlet

LCD display

Off/On

Fan speed selection

Clock setting

Memory reset

Temperature setting

Powerful operation

Operation mode

Quiet operation

Timer setting

Ion operation

Airflow direction 
adjustment

Remote Control

Indicator

Supersonic air 
purifying device

Auto OFF/ON 
button

Receiver

Transmitter

Air inlet 

(side)

Discharged air

Do not touch 
during operation

Note: 

The illustrations in this manual are for explanation purposes only and may differ from the 
actual unit. It is subjected to change without notice for future improvement.

PRODUCT OVERVIEW

Troubleshooting

  Operation delayed for few minutes after restart.

  This is a normal self protection control.

  Sound like water fl owing during operation.

  Caused by refrigerant fl ow inside.

  Mist emerges from indoor unit.

  Condensation effect due to cooling process.

  Noisy during operations.

  Installation work could be slanted or front panel didn’

t close properly.

  Remote control/display does not work.

  Check whether batteries are correctly inserted or need replacement.

  The unit cannot operate.

  Check either circuit breaker is tripped, power plug is inserted correctly or 

timer is used correctly.

  Outdoor unit emits water/steam.

  Condensation or evaporation happens at piping surface.

OP

EN

•  Make sure it is not obstructed.

•  Maximum distances: 10m.

•  Certain fluorescent lights may 

interfere with signal transmission. 
Consult your dealer.

Remote Control Preparation

 

About

Remote Control Signal

•  Timer operation will be based on 

current time set.

•  The batteries can be used for 

approximately 1 year.

•  The batteries must be 

recycled or disposed of 
properly.

1.  Pull out

2. Insert batteries
  (AAA or R03)

3. Press CLOCK button

4. Set 

current 
time

5. Press again to confi rm

•  To operate the unit if the 

remote control is misplaced or 
malfunctioning.

Action

Operation 

mode

Press once

 Automatic 

Operation

Press until “beep” 

sound

 Cooling 

Operation

•  To OFF, press again the Auto OFF/

ON button.

•  To switch the remote control signal 

receiving sound off or on.

1. Press until “beep” sound and 

release. 

2. Press again until “beep-beep” 

sound and release. 

3. Press to switch the sound off or 

on.

  (Long “beep” - OFF; short “beep” 

- ON)

Auto OFF/ON Button

40

CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU-W12DKR

Содержание CS-W12DKR

Страница 1: ... for a long period Ventilate the room regularly Pay attention as to whether the installation rack is damaged after long period of usage Switch off the power supply and unplug before cleaning or servicing Turn off the power supply and unplug if the unit is not used for a long period of time Operation Precautions Warning Do not install remove and reinstall the unit by yourself Improper installation ...

Страница 2: ...g operations Installation work could be slanted or front panel didn t close properly Remote control display does not work Check whether batteries are correctly inserted or need replacement The unit cannot operate Check either circuit breaker is tripped power plug is inserted correctly or timer is used correctly Outdoor unit emits water steam Condensation or evaporation happens at piping surface O ...

Страница 3: ...operly Ensure filters are cleaned or replaced when necessary Ensure inlet and outlet vents of outdoor unit have not been obstructed In heating operation Power indicator blinking no warm air discharge Defrost operation at outdoor unit maximum 12 minutes To save electricity close the curtains when using air conditioner to prevent sunlight and heat from coming in Hint The unit will automatically sele...

Страница 4: ...rations could not be activated at the same time Powerful Quiet and Ion operations could be cancelled by pressing the respective button again Troubleshooting ION indicator on the indoor unit is blinking Press ION button twice If the indicator is still blinking please consult the dealer Indoor fan stops occasionally during Automatic Fan Speed setting Indoorfanstopsoccasionallyduringheatingoperation ...

Страница 5: ...you return from work or wake up When the ON timer is set operation will start 15 minutes for COOL DRY or 30 minutes for AUTO HEAT before the actual set time Use the OFF timer to stop the air conditioner operation at the desired time This can save electricity while you are going out or sleeping The set timer will repeat daily once it is set If there is a power failure you can press SET button to re...

Страница 6: ...there is no obstruction at all air intake and outlet vents After the start of operation for 15 minutes it is normal if the temperature differences between air intake and outlet vents at indoor unit is Operation Temperature Cooling 8 C Heating 14 C Operate the unit for 2 3 hours using ion operation to dry the internal parts Turn off the power supply and unplug Remove the remote control batteries Sw...

Отзывы: