Panasonic CS-W12DKR Скачать руководство пользователя страница 1

9  Oper ating Instr uctions

(GB Standard)

This sign warns of death 

or serious injury.

The appliance is not intended for use by young children or infi

 rm 

person without supervision. Young children should be supervised to 
ensure that they do not play with the appliance.

Replacement or installation of power plugs shall be performed by 
authorized/qualifi

 ed personnel only. The wires in this mains lead are 

coloured in accordance with the following code:

To prevent personal injury, 
injury to others and property 
damage, the following 
instructions must be 
followed.

Incorrect operation due to 
failure to follow instructions 
will cause harm or damage, 
the seriousness of which is 
classifi

 ed as below:

Thank you for purchasing Panasonic Air Conditioner

SAFETY PRECAUTIONS

This symbol denotes 

an action that is 

PROHIBITED.

These symbols denote 

actions that are 

COMPULSORY.

Warning

 

Definition

This sign warns of injury 

or damage to property.

Caution

The instructions to be 
followed are classifi

 ed by 

the following symbols:

Safety Regulation

Operation Condition (

O

C)

Use this air conditioner under the following temperature 
range.

DBT: Dry Bulb Temperature
WBT: Wet Bulb Temperature

Indoor

Outdoor

DBT

WBT

DBT

WBT

Maximum Temperature (COOL)

32

23

43

26

Maximum Temperature (HEAT)

30

24

18

Minimum Temperature (COOL)

16

11

16

11

Minimum Temperature (HEAT)

16

-5

-6           

Different countries may have different colour coding for the wires.

Installation Precautions

Caution

•  Do not pull the cord to 

disconnect the plug.

•  Do not wash the unit with water, benzene, 

thinner or scouring powder.

•   Do not use for other purposes such as 

preservation of food.

•  Do not use any combustible equipment at 

airfl

 ow direction.

•  Do not sit or place anything on the indoor 

or outdoor unit.

•  Do not expose directly to cold air for a 

long period.

•  Ventilate the room regularly.
•  Pay attention as to whether the 

installation rack is damaged after long 
period of usage.

•  Switch off the power supply and unplug 

before cleaning or servicing.

•  Turn off the power supply and unplug if 

the unit is not used for a long period of 
time.

Operation Precautions

Warning

Do not install, remove and reinstall the unit by yourself.
•  Improper installation will cause leakage, electric shock or fi

 re. Please consult an authorized dealer or 

specialist for the installation work.

Caution

•  This air conditioner must be earthed. Improper grounding will cause electric shock.
•  Ensure that the drainage piping is connected properly. Otherwise, water will leak.
•  Current leakage protection equipment must be installed. Otherwise, electric shock or fi

 re may 

occur.

•  Do not install the unit in a potentially explosive atmosphere.

•  Insert the power plug properly.
•  Use specifi

 ed supply cord.

•  If the supply cord is damaged or needed 

to be replaced, it must be replaced by 
the manufacturer or its service agent or 
a similarly qualifi

 ed person in order to 

avoid a hazard.

•  Remove the batteries if the unit is not 

going to be use for a long period of time.

•   New batteries of the same type must be 

inserted following the polarity stated to 
prevent malfunction of the remote control.

•  In case of emergency or abnormal 

condition (burnt, smell, etc) occurs, turn 
off the power supply and unplug.

Warning

•  Do not share power outlet.
•  Do not modify power cord.
•  Do not use an extension cord.
•  Do not operate with wet hands.
•  Do not operate or stop the unit by inserting 

or pulling out the power plug.

•   Do not insert fi

 nger or other objects into the 

indoor or outdoor unit.

•  Do not attempt to repair the unit by 

yourself.

•  Do not use rechargeable (Ni-Cd) batteries.
•  Keep the remote control away from infants 

and small children to prevent them from 
accidentally swallowing the batteries.

39

C S -W 7 D K R C U -W 7 D K R / C S -W 9D K R C U -W 9D K R / C S -W 1 2 D K R C U - W 1 2 D K R

Содержание CS-W12DKR

Страница 1: ... for a long period Ventilate the room regularly Pay attention as to whether the installation rack is damaged after long period of usage Switch off the power supply and unplug before cleaning or servicing Turn off the power supply and unplug if the unit is not used for a long period of time Operation Precautions Warning Do not install remove and reinstall the unit by yourself Improper installation ...

Страница 2: ...g operations Installation work could be slanted or front panel didn t close properly Remote control display does not work Check whether batteries are correctly inserted or need replacement The unit cannot operate Check either circuit breaker is tripped power plug is inserted correctly or timer is used correctly Outdoor unit emits water steam Condensation or evaporation happens at piping surface O ...

Страница 3: ...operly Ensure filters are cleaned or replaced when necessary Ensure inlet and outlet vents of outdoor unit have not been obstructed In heating operation Power indicator blinking no warm air discharge Defrost operation at outdoor unit maximum 12 minutes To save electricity close the curtains when using air conditioner to prevent sunlight and heat from coming in Hint The unit will automatically sele...

Страница 4: ...rations could not be activated at the same time Powerful Quiet and Ion operations could be cancelled by pressing the respective button again Troubleshooting ION indicator on the indoor unit is blinking Press ION button twice If the indicator is still blinking please consult the dealer Indoor fan stops occasionally during Automatic Fan Speed setting Indoorfanstopsoccasionallyduringheatingoperation ...

Страница 5: ...you return from work or wake up When the ON timer is set operation will start 15 minutes for COOL DRY or 30 minutes for AUTO HEAT before the actual set time Use the OFF timer to stop the air conditioner operation at the desired time This can save electricity while you are going out or sleeping The set timer will repeat daily once it is set If there is a power failure you can press SET button to re...

Страница 6: ...there is no obstruction at all air intake and outlet vents After the start of operation for 15 minutes it is normal if the temperature differences between air intake and outlet vents at indoor unit is Operation Temperature Cooling 8 C Heating 14 C Operate the unit for 2 3 hours using ion operation to dry the internal parts Turn off the power supply and unplug Remove the remote control batteries Sw...

Отзывы: