32
Operation mode
i AUTO-X :
The fast cooling is ideal when you come home on a hot day.
COOL
:
Provides ef
fi
cient comfort cooling to suit your needs.
DRY
:
Unit operates at low fan speed to give a gentle cooling operation.
nanoe-G in-
fi
lter deactivation
Depending on the unit’s accumulated operation time, nanoe-G in-
fi
lter deactivation may be activated only
once a day after the unit is turned off.
To remove the moisture left in the internal parts, the fan will operate for 30 minutes with the
fl
ap opened
slightly. This process is only applicable when the unit is operated in COOL/DRY mode before turned off.
Then, nanoe-G deactivates viruses/bacteria on the
fi
lter for 2 hours with the fan stopped and
fl
ap closed.
Do not turn off the power supply during this operation. After power failure, this operation will not resume.
DUST SENSOR function
• Depending on the level of particles detected by the dust sensor, nanoe TECHNOLOGY is optimally
controlled to purify the air, thus creating a clean room environment.
• This feature is automatically turned ON when unit is operated. It is turned OFF if nanoe TECHNOLOGY
is turned ON manually.
• During the initialization (when unit is turned ON or nanoe TECHNOLOGY is turned OFF manually), the
dust sensor indicator turns RED for 20 seconds.
• If the dust sensor detects a high level of particles, the dust sensor indicator turns RED and nanoe
TECHNOLOGY turns ON.
• If the dust sensor detects a low level of particles, the dust sensor indicator turns WHITE and nanoe
TECHNOLOGY turns OFF.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
COOL:
26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air
fl
ow direction
In COOL/DRY mode:
If AUTO is set, the
fl
ap swings left/right and up/down automatically.
In i AUTO-X mode:
If AUTO is set, the horizontal
fl
ap is
fi
xed at the lower position and shift to the upper position after
reaches set temperature. If manual is set, the horizontal
fl
ap and vertical
fl
ap are
fi
xed at the
predetermined position.
Auto restart control
If power is resumed after a power failure, the operation will restart automatically after a period of time
with previous operation mode and air
fl
ow direction.
• This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32 (89.6)
23 (73.4)
46 (114.8)
26 (78.8)
Min.
16 (60.8)
11 (51.8)
16 (60.8)
11 (51.8)
DBT: Dry bulb temperature, WBT: Wet bulb temperature