10 Installation Information
10.1. ATTACHED ACCESSORIES
10.2. SELECT THE BEST LOCATION
10.2.1. INDOOR UNIT
·
There should not be any heat source or steam near the unit.
·
There should not be any obstacles blocking the air circulation.
·
A place where air circulation in the room is good.
·
A place where drainage can be easily done.
·
A place where noise prevention is taken into consideration.
·
Do not install the unit near the door way.
·
Ensure the spaces indicated by arrows from the wall, ceiling or other obstacles.
·
Indoor unit of this room air conditioner shall be installed on the wall in a height of at least 2.3m.
10.2.2. OUTDOOR UNIT
·
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not
obstructed.
·
There should not be any animal or plant which could be affected by hot discharged air.
·
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
·
Do not place any obstacles which may cause a short circuit of the discharged air.
10.2.3. PIPING LENGTH
MODEL
Piping size
Rated
Length (m)
Max. Elevation
(m)
Max. Piping
Length (m)
Gas
Liquid
VC70KE
3/8”
1/4”
7
5
10
VC90KE
3/8”
1/4”
7
5
10
VC120KE
1/2”
1/4”
10
5
15
*1.The additional gas charge is unnecessary up to the Max. piping length. (CS-VC70KE, CS-VC90KE)
*2. The above models (CS-VC120KE) will be installed at a 15 m (max) distance.
The refrigerant should be added 75g. ( 15m - 10m ) x 15g = 75g
35
CS-VC70KE / CU-VC70KE / CS-VC90KE / CU-VC90KE / CS-VC120KE / CU-VC120KE
Содержание CS-VC70KE
Страница 4: ...2 Functions 2 1 REMOTE CONTROL 4 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 5: ...2 2 INDOOR UNIT 5 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 6: ...2 3 OUTDOOR UNIT 6 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 19: ...8 2 5 Soft Dry Operation Time Diagram 19 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 36: ...10 3 INDOOR OUTDOOR UNIT INSTALLATION DIAGRAM 36 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 48: ...13 Troubleshooting Guide 48 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 51: ...14 2 OPERATION CHARACTERISTICS 51 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 52: ...52 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 57: ...16 Printed Circuit Board 16 1 INDOOR UNIT MAIN 57 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 60: ...17 2 CS VC120KE 17 2 1 Exploded View 60 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 62: ...17 3 CU VC70KE CU VC90KE 17 3 1 Exploded View 62 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...
Страница 64: ...17 4 CU VC120KE 17 4 1 Exploded View 64 CS VC70KE CU VC70KE CS VC90KE CU VC90KE CS VC120KE CU VC120KE...