background image

8

TROUBLESHOOTING

The following symptoms do not indicate malfunction.

The following symptoms do not indicate malfunction.

SYMPTOM

SYMPTOM

CAUSE

CAUSE

Mist emerges from indoor unit.

•  Condensation effect due to cooling process.

Water 

fl

 owing sound during operation.

• Refrigerant 

fl

 ow inside the unit.

The room has a peculiar odour.

•  This may be due to damp smell emitted by the wall, 

carpet, furniture or clothing.

Indoor fan stops occasionally during automatic fan speed 

setting.

•  This helps to remove the surrounding odours.

Operation is delayed a few minutes after restart.

•  The delay is a protection to the unit’s compressor.

Outdoor unit emits water/steam.

•  Condensation or evaporation occurs on pipes.

Timer indicator is always on.

•  The timer setting repeats daily once set.

Power indicator blinks before the unit is switched on.

•  This is a preliminary step in preparation for the operation 

when the ON timer has been set.

Cracking sound during operation. 

•  Changes of temperature cause the expansion/contraction 

of the unit.

Check the following before calling for servicing.

Check the following before calling for servicing.

SYMPTOM

SYMPTOM

CHECK

CHECK

Cooling operation is not working ef

fi

 ciently.

•  Set the temperature correctly.

•  Close all doors and windows.

•  Clean or replace the 

fi

 lters.

•  Clear any obstruction at the air inlet and air outlet vents.

Noisy during operation.

•  Check if the unit has been installed at an incline.

•  Close the front panel properly.

Remote control does not work.

(Display is dim or transmission signal is weak.)

•  Insert the batteries correctly.

•  Replace weak batteries.

The unit does not work.

•  Check if the circuit breaker is tripped.

•  Check if timers have been set.

The unit does not receive the signal from the remote 

control.

•  Make sure the receiver not obstructed.

• Certain 

fl

 uorescent lights may interfere with signal 

transmitter. Please consult authorized dealer.

The unit stops and the timer indicator blinks.

Use remote control to retrieve error code.

TIMER

SET

CANCEL

ON

OFF

1

2

3

SET CHECK CLOCK

RESET

AC

RC

1

Press for 5 

seconds.

3

Press for 5 

seconds to 

quit checking.

2

Press until you hear 

beep sound, then 

write down the error 

code.

Note:

•  For certain errors, you 

may restart the unit for 

limited operation with 4 

beeps during operation 

starts.

4

  Turn the unit off and reveal the error code to authorized dealer.

Содержание CS-S9JKUW-1

Страница 1: ...U S12JKU 1 CS S18JKU 1 CU S18JKU 1 CS S22JKU 1 CU S22JKU 1 Multi Split Outdoor Unit CU 2S18JBU 1 Before operating the unit read these operating instructions thoroughly and keep them for future referen...

Страница 2: ...stall the unit Improper installation and handling will cause leakage electric shock or fire Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result in...

Страница 3: ...Control Outdoor Unit Power Supply WARNING WARNING POWER SUPPLY Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Do not share the same power outle...

Страница 4: ...Multi Split System CS S9JKUW 1 CS S9JKUW 1 CU 2S18JBU 1 25 Amps 208 230V CS S9JKUW 1 CS S12JKUW 1 CU 2S18JBU 1 CS S12JKUW 1 CS S12JKUW 1 CU 2S18JBU 1 Living room Living room Multi Split Outdoor Unit M...

Страница 5: ...ard then release Cooling Press the button to turn off 8 AIR PURIFYING FILTER Vacuum the air purifying filter It is recommended to clean the filter every 6 months Replace the filter every 3 years or re...

Страница 6: ...the remote control s button 1 TO TURN ON OR OFF THE UNIT Please be aware of the OFF indication on the remote control display to prevent the unit from starting stopping improperly 2 TO SET TEMPERATURE...

Страница 7: ...all modes and can be cancelled by pressing the respective button again QUIET POWERFUL Cannot be selected at the same time TO SET THE TIMER TO SET THE TIMER To turn ON or OFF the unit at a preset time...

Страница 8: ...ing Check the following before calling for servicing SYMPTOM SYMPTOM CHECK CHECK Cooling operation is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace...

Страница 9: ...untry hazardous waste disposal hotline FOR SEASONAL INSPECTION AFTER EXTENDED NON USE Checking of remote control batteries No obstruction at air inlet and air outlet vents After 15 minutes of operatio...

Страница 10: ...MEMO...

Страница 11: ...MEMO...

Страница 12: ...CK RESET AC RC 2 1 3 MODE MODE AUTO DRY COOL Select the desired mode 1 OFF ON OFF ON Start stop the operation 2 TEMP TEMP Select the desired temperature 3 Printed in Malaysia OSSC1004 00 F567673 Panas...

Отзывы: