Safety precautions

f) Precautions shall be taken to avoid 

excessive vibration or pulsation to 
refrigerating piping.

g) Ensure protection devices, refrigerating 

piping and 

fi

 ttings are well protected 

against adverse environmental effects 
(such as the danger of water collecting and 
freezing in relief pipes or the accumulation 
of dirt and debris).

h) Expansion and contraction of long runs 

piping in refrigerating systems shall be 
designed and installed securely (mounted 
and guarded) to minimize the likelihood 
hydraulic shock damaging the system.

i) Protect the refrigerating system from 

accidental rupture due to moving furniture 
or reconstruction activities.

j) To ensure no leaking, 

fi

 eld-made refrigerant 

joints indoors shall be tightness tested. 
The test method shall have a sensitivity of 
5 grams per year of refrigerant or better 
under a pressure of at least 0.25 times the 
maximum allowable pressure (>1.04MPa, 
max 4.15MPa). No leak shall be detected.

1. Installation (Space)

• Product with 

fl

 ammable refrigerants, shall 

be installed according to the minimum room 
area, Amin (m

2

) mentioned in Table A of the 

Installation Instructions.

• In case of 

fi

 eld charge, the effect on 

refrigerant charge caused by the different pipe 
length has to be quanti

fi

 ed, measured and 

labelled.

• Must ensure the installation of pipe-work shall 

be kept to a minimum. Avoid use dented pipe 
and do not allow acute bending.

• Must ensure that pipe-work shall be protected 

from physical damage.

• Must comply with national gas regulations, 

state municipal rules and legislation. Notify 
relevant authorities in accordance with all 
applicable regulations.

• Must ensure mechanical connections be 

accessible for maintenance purposes.

• In cases that require mechanical ventilation, 

ventilation openings shall be kept clear of 
obstruction.

• When disposal of the product, do follow to the 

precautions in #12 and comply with national 
regulations.
Always contact to local municipal of

fi

 ces for 

proper handling.

2. Servicing
2-1. Service personnel

• The system is inspected, regularly supervised 

and maintained by a trained and certi

fi

 ed 

service personnel who is employed by the 
person user or party responsible.

• Ensure the actual refrigerant charge is in 

accordance with the room size within which 
the refrigerant containing parts are installed.

• Ensure refrigerant charge not to leak.
• Any quali

fi

 ed person who is involved with 

working on or breaking into a refrigerant 
circuit should hold a current valid certi

fi

 cate 

from an industry-accredited assessment 
authority, which authorizes their competence 
to handle refrigerants safely in accordance 
with an industry recognised assessment 
speci

fi

 cation.

• Servicing shall only be performed 

as recommended by the equipment 
manufacturer. Maintenance and repair 
requiring the assistance of other skilled 
personnel shall be carried out under the 
supervision of the person competent in the 
use of 

fl

 ammable refrigerants.

• Servicing shall be performed only as 

recommended by the manufacturer.

2-2. Work

• Prior to beginning work on systems containing 

fl

 ammable refrigerants, safety checks are 

necessary to ensure that the risk of ignition 

is minimised. For repair to the refrigerating 

system, the precautions in #2-2 to #2-8 must be 

followed before conducting work on the system.

• Work shall be undertaken under a controlled 

procedure so as to minimize the risk of a 

fl

 ammable gas or vapour being present while 

the work is being performed.

• All maintenance staff and others working in the 

local area shall be instructed and supervised 

on the nature of work being carried out.

• Avoid working in con

fi

 ned spaces. Always 

ensure away from source, at least 2 meter of 

safety distance, or zoning of free space area 

of at least 2 meter in radius.

• Wear appropriate protective equipment, including 

respiratory protection, as conditions warrant.

• Keep all sources of ignition and hot metal 

surfaces away.

Содержание CS-RZ25VKRW

Страница 1: ...installer before installation Remote control is packaged in the indoor unit and removed by the installer before installation Kindly consult authorised dealer for connectivity validity ACXF55 22390 Mod...

Страница 2: ...rol 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press and set the time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm Re...

Страница 3: ...may differ from the actual unit They are subject to change without notice for future improvement B Basic operation 2 Press MODE to select the desired mode AUTO HEAT COOL FAN DRY 1 Press OFF ON to sta...

Страница 4: ...ge of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not use means to accelerate the defrosting process or to clean oth...

Страница 5: ...of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagatio...

Страница 6: ...l the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of...

Страница 7: ...low to the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supe...

Страница 8: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 9: ...supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing t...

Страница 10: ...mmenced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for ha...

Страница 11: ...sure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e...

Страница 12: ...operation reduces airflow noise To adjust airflow direction Do not adjust the flap by hand To adjust airflow direction To adjust airflow direction AIR SWING Upper direction CS RZ25 35 42VKRW CS MRZ16...

Страница 13: ...elled manually or due to power failure you can restore the timer again by pressing or to select respective or then press The nearest timer setting will be displayed and will activate in sequence Timer...

Страница 14: ...kes a while to warm up COOL Provides efficient comfort cooling to suit your needs DRY Unit operates at low fan speed to give a gentle cooling operation FAN To circulate air in the room Energy saving t...

Страница 15: ...it 2 DBT WBT DBT WBT DBT WBT COOL Max 32 89 6 23 73 4 46 114 8 26 78 8 46 114 8 26 78 8 Min 16 60 8 11 51 8 10 14 0 10 14 0 HEAT Max 30 86 0 24 75 2 18 64 4 24 75 2 18 64 4 Min 16 60 8 15 5 0 15 5 0 1...

Страница 16: ...ir filter Insert into the unit Anti bacterial filter Anti bacterial filter Fitting location may vary on models Clean the filter whenever necessary Wash rinse the filter gently with water to avoid dama...

Страница 17: ...e wall carpet furniture or clothing Cracking sound during operation Changes of temperature caused the expansion contraction of the unit Water flowing sound during operation Refrigerant flow inside the...

Страница 18: ...around the air inlet and outlet vents Use Auto OFF ON button to select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet...

Страница 19: ...ensor H 32 Outdoor heat exchanger temperature sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse...

Страница 20: ...ved WARNING This symbol shows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol sho...

Отзывы: