background image

30

ON

OFF

SET

TIMER

CANCEL

OFF/ON

AIR SWING

TEMP

OFF/ON

MODE

SLEEP

FAN SPEED/

QUIET

POWERFUL/

ECO

AIR CONDITIONER

How to Use

To adjust FAN SPEED and QUIET condition

FAN SPEED:

• When AUTO FAN is selected, the fan speed is adjusted 

automatically according to the operation mode.

QUIET: 

• This operation reduces air

fl

 ow noise.

FAN SPEED/

QUIET

POWERFUL:

To reach the desired temperature quickly

• This operation is automatically stop after 20 minutes.

ECO: 

• To reduce power consumption for better energy saving 

without sacri

fi

 cing comfort.

To switch between POWERFUL/ECO

POWERFUL/

ECO

(exit setting)

Not used in 

normal 

operation.

Press to turn

the Wireless

LAN feature

ON or OFF.

Press to restore the 

remote control to 

default setting.

• This operation combines both nanoe™X and nanoe™-G 

(nanoe™ TECHNOLOGY).

• nanoe™ TECHNOLOGY automatically starts when the 

unit is turned on.

• Press 

 to turn ON or OFF this operation manually.

• This operation can be activated even when the unit is OFF. 

Note that the 

fl

 ap and fan speed will operate according to 

the remote control setting.

• If a power failure occurs during this operation, this 

operation resumes immediately when power resumes.

To enjoy fresher and cleaner environment

Indicators

POWER

 

TIMER

  

nanoe

TECHNOLOGY

  

  

Upper direction: 

• Do not adjust the 

fl

 ap by hand.

* For details operation, refer “To Learn More....”

Lateral direction: 

• For lateral direction, it is 

manually adjustable as 

shown.

To adjust air

fl

 ow direction 

AIR SWING

Upper direction

Lateral
direction

Содержание CS-RU9YKA

Страница 1: ...g the unit please read these operating instructions thoroughly and keep them for future reference Before installation the installer should Read the Installation Instructions then request the customer...

Страница 2: ...R03 3 8 A 1 5 12 am pm 24 2 ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SLEEP FAN SPEED QUIET POWERFUL ECO AIR CONDITIONER ON OFF TIMER CANCEL AIR SWING SLEEP FAN SPEED QUIET POWERFUL EC...

Страница 3: ...3 B 2 DRY AUTO COOL 1 POWER ON 3 TEMP UP TEMP DOWN 16 0 C 30 0 C 60 F 86 F 10 C F 4 11 12 13 14 15 16 18 19 AAA R03 2 2 Panasonic...

Страница 4: ...4...

Страница 5: ...5 ON Ni Cd ELCB RCD ELCB BS...

Страница 6: ...6 nanoe G R32 Amin m Amin m A R32 R410A R22 R32 R22 R32 R22 R32 R410A R32 R410A R32 R410A R22 R32 R410A 1 2 R32 R410A AHU a b c d...

Страница 7: ...7 e f g h i j 5 0 25 1 04 MPa 4 15 MPa 1 A Amin m 12 2 2 1 2 2 2 2 2 8 2 2...

Страница 8: ...8 2 3 2 4 CO2 2 5 2 6 2 7 2 8...

Страница 9: ...9 6 7 5 1 04 MPa 4 15 MPa 0 25 LFL 25 8 3 4 5...

Страница 10: ...10 10 a b c d e f g h 80 i j k 11 8 OFN OFN OFN OFN 9 OFN 7...

Страница 11: ...11 12...

Страница 12: ...E SLEEP FAN SPEED QUIET POWERFUL ECO AIR CONDITIONER FAN SPEED QUIET FAN SPEED AUTO FAN QUIET FAN SPEED QUIET POWERFUL 20 ECO POWERFUL ECO POWERFUL ECO nanoe X nanoe G nanoe TECHNOLOGY nanoe TECHNOLOG...

Страница 13: ...EP POWERFUL ECO FAN SPEED QUIET POWERFUL ECO POWERFUL QUIET FAN SPEED 0 5 1 2 3 4 5 6 7 8 9 OFF 0 0h SLEEP ON OFF SET TIMER CANCEL 1 2 3 1 TIMER ON TIMER OFF 22 00 OFF OFF 2 3 SET ON OFF CANCEL ON OFF...

Страница 14: ...R COOL DRY COOL 26 0 C 28 0 C 79 F 82 F COOL DRY COOL DRY nanoe X nanoe X nanoe X COOL DRY 2 5 nanoe TECHNOLOGY 2 C F DBT WBT DBT WBT COOL 32 89 6 23 73 4 46 114 8 26 78 8 16 60 8 11 51 8 16 60 8 11 5...

Страница 15: ...15 H 99 pH 7 40 C 104 F nanoeTM G 2 2 nanoe G AUTO OFF ON 1 2 2 AUTO OFF ON 1 3 4...

Страница 16: ...16 POWER TIMER ON 15 TIMER ON nanoe G nanoe TECHNOLOGY nanoe X nanoe TECHNOLOGY OFF ON COOL nanoe TECHNOLOGY nanoe TECHNOLOGY...

Страница 17: ...17 AUTO OFF ON 1 2 AUTO OFF ON AUTO 3 AUTO OFF ON COOL 4 AUTO OFF ON 5 AUTO OFF ON COOL 15 COOL 8 C 14 4 F nanoe TECHNOLOGY 2 3...

Страница 18: ...2 H 14 H 15 H 16 CT H 17 H 19 H 21 H 23 1 H 24 2 H 25 H 26 ION H 27 H 28 1 H 30 H 31 H 32 2 H 33 H 34 H 35 H 36 H 37 H 38 H 39 H 41 H 50 H 51 H 52 H 58 H 59 H 64 H 67 nanoe H 70 H 71 H 72 H 85 H 97 H...

Страница 19: ...19 Pb...

Страница 20: ...ime as 12 hour am pm or 24 hour 2 Press to confirm Use the remote control within 8 m from the remote control receiver on the indoor unit A new built in Network Adaptor that allows you to control your...

Страница 21: ...ly 10 seconds to show the temperature as C or F Table of Contents Safety Precautions 22 29 How to Use 30 31 To Learn More 32 Cleaning the Air Conditioner 33 Troubleshooting 34 36 Information 37 Access...

Страница 22: ...plosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not...

Страница 23: ...ic shock nanoe G generator Do not touch the sharp pin which may cause injury Power supply Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire To pr...

Страница 24: ...al the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use o...

Страница 25: ...the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised...

Страница 26: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 27: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Страница 28: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Страница 29: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Страница 30: ...reless LAN feature ON or OFF Press to restore the remote control to default setting This operation combines both nanoe X and nanoe G nanoe TECHNOLOGY nanoe TECHNOLOGY automatically starts when the uni...

Страница 31: ...ion can be cancelled by pressing the respective button until the sleep timer reaches 0 0h SLEEP How to Use To connect to a network For Wireless LAN Module operation setup please refer to Setup Instruc...

Страница 32: ...flow direction This control is not applicable when TIMER is set nanoe X filter deactivation Depending on the unit s accumulated operation time the nanoe X may be activated only once a day after the un...

Страница 33: ...filters Once every 2 weeks Wash rinse the filters gently with water to avoid damaging the surface Dry the filters thoroughly under a shade away from fire or direct sunlight Replace any damaged filter...

Страница 34: ...nmental factors After extended use dust may cover the front panel grilles and the wall surrounding the unit The dust accumulation is due to the air purification effect of negative ions from nanoe G Re...

Страница 35: ...tion has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F The units will not be used for an...

Страница 36: ...heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnorma...

Страница 37: ...ght be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a flam...

Страница 38: ...Memo...

Страница 39: ...Memo...

Страница 40: ...Printed in Malaysia Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ACXF55 32310 SS0122 0...

Отзывы: