Panasonic CS-RE12NKX Скачать руководство пользователя страница 49

49 

 

NO. 

PART NAME 

QTY. 

CS-RE9NKX 

CS-RE12NKX 

CS-RE15NKX  REMARK 

CHASSIS COMPLETE 

CWD50C1644 

CWD50C1644 

CWD50C1738 

 

 

FAN MOTOR(DC,280-340V,30W) 

ARW7648AC 

ARW7648AC 

ARW7648AC 

 

 

CROSS FLOW FAN COMPLETE 

CWH02C1095 

CWH02C1095 

CWH02C1095 

 

 

BEARING ASS'Y 

CWH64K1008 

CWH64K1008 

CWH64K1008 

 

 

EVAPORATOR 

CWB30C3981 

CWB30C3977 

CWB30C3978 

 

 

AUXILIARY TUBE ASS'Y 

CWT01C5455 

CWT01C5455 

CWT01C5456 

 

 

DRAIN PLUG 

CWH521096 

CWH521096 

CWH521096 

 

 

DISCHARGE GRILLE COMPLETE 

CWE20C3276 

CWE20C3276 

CWE20C3276 

 

 

AIR SWING 
MOTOR(DC,12V,200OHM) 

CWA981292 

CWA981292 

CWA981292 

 

 

10 

HORIZONTAL AIR FLOW  VANE (L) 

CWE24C1292 

CWE24C1292 

CWE24C1292 

 

 

11 

HORIZONTAL AIR FLOW VANE (R) 

CWE24C1291 

CWE24C1291 

CWE24C1291 

 

 

12 

VERTICAL AIR FLOW VANE 

CWE24C1413 

CWE24C1413 

CWE24C1413 

 

 

13 

CONTROL BOX COMPLETE 

CWH14C9275 

CWH14C9276 

CWH14C9279 

 

 

14 

CONTROL BOARD CASING  

CWH102487 

CWH102487 

CWH102487 

 

 

15 

PARTICULAR PIECE 

CWD933089 

CWD933089 

CWD933089 

 

 

16 

TERMINAL BOARD COMPLETE 

CWA28C2546 

CWA28C2547 

CWA28C2546 

 

 

17 

POWER SUPPLY CORD 
COMPLETE 

CWA20C3068 

CWA20C3068 

CWA20C3074 

 

 

18 

MAIN PCB 

CWA73C5921 

CWA73C5922 

CWA73C5923 

 

 

19 

SENSOR 

CWA50C2883 

CWA50C2883 

CWA50C2883 

 

 

20 

INDICATOR HOLDER 

CWD933546 

CWD933546 

CWD933546 

 

 

21 

INDICATOR PCB 

CWA746860 

CWA746860 

CWA746860 

 

 

22 

CONTROL BOARD TOP COVER 

CWH131523 

CWH131523 

CWH131523 

 

 

23 

CONTROL BOARD BACK COVER 

CWH131526 

CWH131526 

CWH131526 

 

 

24 

REMOTE CONTROL 

CWA75C3755 

CWA75C3755 

CWA75C3755 

 

 

25 

FRONT GRILLE COMPLETE 

CWE11C5307 

CWE11C5307 

CWE11C5307 

 

 

26 

INTAKE GRILLE 

CWE22K1594 

CWE22K1594 

CWE22K1594 

 

 

27 

GRILLE DOOR 

CWE14C1092 

CWE14C1092 

CWE14C1092 

 

 

28 

AIR FILTER 

CWD001339 

CWD001339 

CWD001339 

 

 

29 

ANTI-BACTERIAL FILTER 

CWD001280 

CWD001280 

CWD001280 

 

 

30 

SCREW-FRONT GRILLE 

XTT4+16CFJ 

XTT4+16CFJ 

XTT4+16CFJ 

 

 

31 

CAP-FRONT GRILLE 

CWH521236A 

CWH521236A 

CWH521236A 

 

 

32 

DRAIN HOSE 

CWH851136 

CWH851136 

CWH851136 

 

 

33 

OPERATING INSTRUTIONS 

CWF568412 

CWCWF568412 

CWF568412 

 

 

34 

INSTALLATION INSTRUCTION 

CWF615235 

CWCWF615235 

CWF615235 

 

 

35 

INSTALLATION INSTRUCTION 

CWF615236 

CWCWF615236 

CWF615236 

 

 

36 

INSTALLATION PLATE 

CWH361133 

CWH361133 

CWH361133 

 

 

 (Note) 

 

All parts are supplied from PAPAGZ, China  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CS-RE12NKX

Страница 1: ...ndoor Unit 25 10 3 Outdoor Unit 27 11 Service Mode 30 11 1 Auto OFF ON Button 30 11 2 Select Remote Control Transmission Code 30 11 3 Operate and Display of Remote Control 31 12 Operation Control 33 12 1 Basic Function 33 12 2 Indoor Fan Motor Operation 34 12 3 Outdoor Fan Motor Operation 34 13 Protection control 37 13 1 Protection Control For All Operations 37 This service information is designed...

Страница 2: ...Piping Air Temperature Control Heating 40 14 Troubleshooting Guide 42 14 1 Refrigeration cycle system 42 14 2 Breakdown Self Diagnosis Function 43 15 Disassembly and Assembly Instructions 45 16 Exploded View and Replacement Pars List 48 16 1 Indoor Unit 48 16 2 Outdoor Unit 50 ...

Страница 3: ...se it may cause electrical shock and fire in case equipment breakdown or insulation breakdown 8 This equipment must be properly earthed Earth line must not be connected to gas pipe water pipe earth of lightning rod and telephone Otherwise it may cause electrical shock in case equipment breakdown or insulation breakdown 9 Do not use joint cable for indoor outdoor connection cable Use the specified ...

Страница 4: ... pole disconnection incorporated in the fixed wiring is to be provided 1 Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surrounding of the unit it may cause fire 2 Carry out drainage piping as mentioned in installation instructions If drainage is not perfect water may enter the room and damage the furniture 3 Do not touch outdoor unit...

Страница 5: ...A H L QLo Hi 42 Lo 27 QLo 25 Hi 42 Lo 33 QLo 25 Indoor Noise Power Level 58 58 dB A H L Hi 48 Lo Hi 50 Lo HEATING Outdoor Noise Power Level 64 66 Max Current A Max Input Power W 6 30 1 350k 8 40 1 600k Starting Current A 4 00 5 40 Type Hermetic Motor Hermetic Motor Motor Type BRUSHLESS 6 poles BRUSHLESS 6 poles Compressor Output Power W 750 900 Type Cross flow fan Cross flow fan Material AS GF30 A...

Страница 6: ... Fin Material Pre coated Pre coated Fin Type Slit Fin Slit Fin Row x Stage x FPI 2 x 15 x 19 2 x 15 x 19 Indoor Heat Exchanger Size W x H x L mm 610 x 315 x 25 4 610 x 315 x 25 4 Fin Material Pre coated Pre coated Fin Type Slit Fin Slit Fin Row x Stage x FPI 1 x 24 x 19 2 x 24 x 17 Outdoor Heat Exchanger Size W x H x D mm 661 x 504 x 18 19 703x 504 x 18 19 Material P P HONEY COMB P P HONEY COMB Ai...

Страница 7: ...Hi 51 Lo HEATING Outdoor Noise Power Level 67 Max Current A Max Input Power W 10 5 2 280k Starting Current A 6 40 Type Hermetic Motor Motor Type BRUSHLESS 6 poles Compressor Output Power W 700 Type Cross flow fan Material AS GF30 Motor Type DC 8 poles Input Power W Output Power W 30 O Lo rpm 730 Lo rpm 800 Me rpm 1040 Speed COOLIN G Hi rpm 1320 O Lo rpm 740 Lo rpm 900 Me rpm 1060 Indoor Fan Speed ...

Страница 8: ...door Heat Exchanger Size W x H x L mm 610 x 315 x 25 4 Fin Material Pre coated Fin Type Slit Fin Row x Stage x FPI 2 x 24 x 17 Outdoor Heat Exchanger Size W x H x D mm 703x 504 x 18 19 Material P P HONEY COMB Air Filter Type One touch Power Supply Indoor Power Supply Cord A 16A Thermostat Protection Device COOLING HEATING TEMPERATURE C DRY BULB WET BULB DRY BULB WET BULB Maximum 32 23 30 Indoor Op...

Страница 9: ...ty Improvement o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to protect compressor Operation Improvement o Quiet mode to reduce the indoor unit operating sound o Powerful mode to reach the desired room temperature quickly o 12 hour timer Serviceability Improvement o Breakdown Self Diagnosis Funct...

Страница 10: ...ET button to restore the remote control s default setting POWER GREEN TIMER ORANGE QUIET GREEN INDICATOR POWERFUL RED Air inlet side Air outlet Air inlet rear OFF ON Airflow direction adjustment Timer setting Temperature setting Transmitter Fan speed selection Front Panel Air Filter Vertical airflow direction louver Horizontal airflow direction louver Receiver ...

Страница 11: ...11 5 Dimensions 5 1 Indoor Unit Unit mm ...

Страница 12: ...12 5 2 Outdoor Unit CU RE9NKX Unit mm CU RE12NKX CU RE15NKX ...

Страница 13: ...13 6 Refrigeration Cycle Diagram CS CU RE9NKX CS CU RE12NKX CU CU RE15NKX COOLING HEATING ...

Страница 14: ...14 7 Block Diagram CS CU RE9NKX CS CU RE12NKX ...

Страница 15: ...15 CS CU RE15NKX ...

Страница 16: ...16 8 Wiring Diagram CS CU RE9NKX ...

Страница 17: ...17 CS CU RE12NKX ...

Страница 18: ...18 CS CU RE15NKX ...

Страница 19: ...19 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board TOP VIEW BOTTOM VIEW ...

Страница 20: ...20 9 1 2 Indicator receiver TOP VIEW BOTTOM VIEW ...

Страница 21: ...21 9 2 Outdoor Unit 9 2 1 CU RE9NKX TOP VIEW BOTTOM VIEW ...

Страница 22: ...22 CU RE12NKX TOP VIEW BUTTOM VIEW ...

Страница 23: ...23 CU RE15NKX TOP VIEW BUTTOM VIEW ...

Страница 24: ...cted There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do not place any obstacles which may cause a short circuit of the discharged air If piping length is over the rated length additional refrigerant should be added as shown in the table below Example If the unit is installed at a 10...

Страница 25: ...all with 5 screws or more If mounting the unit on the wall consider using anchor bolts Always mount the installation plate horizontally by aligning the marking off line with the thread and using a level gauge 2 Drill the piping plate hole with ø70 mm hole core drill Put measuring tape at position as shown in the diagram above The hole centre is obtained by measuring the distance namely 115 mm and ...

Страница 26: ...26 10 2 3 Indoor Unit Installation ...

Страница 27: ...t roof please consider strong wind and earthquake Please fasten the installation stand firmly with bolt or nails 10 3 2 Connecting the Piping 10 3 2 1 Connecting the piping to indoor unit Please make flare after inserting flare nut locate at joint portion of tube assembly onto the copper pipe In case of using long piping Connect the piping Align the center of piping and sufficiently tighten the fl...

Страница 28: ... 0 Mpa to 76 cmHg 0 1 Mpa Then evacuate the air approximately ten minutes 4 Close the Low side valve of the charging set and turn off the vacuum pump Make sure that the needle in the gauge does not move after approximately five minutes Note BE SURE TO FOLLOW THIS PROCEDURE IN ORDER TO AVOID REFRIGEANT GAS LEAKAG 5 Disconnect the charging horse from the vacuum pump and from the service port of the ...

Страница 29: ...lamper 4 Attach the control board cover back to the original position with the screw 5 For wiring stripping and connection requirement refer to instruction 10 2 4 of indoor unit 10 3 5 Pipe Insulation 1 Please carry out insulation at pipe connection portion as mentioned in Indoor Outdoor Unit Installation Diagram Please warp the insulated piping end to prevent water from going inside the piping 2 ...

Страница 30: ...switch is continuously pressed between 16 to 21 seconds either H14 error detection selection mode or remote controller s signal receiving sound can be cancelled or turned on 11 2 Select Remote Control Transmission Code There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor PCB The indoor unit will only operate when received signal with same transmiss...

Страница 31: ... changes as follows by pressing the AIR SWING button 11 3 5 AIR SWING button To adjust vertical airflow directions by pressing AIR SWING button 5 options 11 3 6 QUIET AND POWERFULL button Start Quiet operation Press QUIET button until QUIET displaying on remote control display to identify Quiet mode operating Start POWERFUL operation Press POWERFUL button until POWERUL displays on remote control d...

Страница 32: ...etting can operate only once If the OFF ON button on the remote control or the AUTO Switch on the indoor unit is pressed the timer setting will be cancelled If Auto Restart Control occurs timer setting will be cancelled During the operation if the ON Timer or ON OFF Timer is set the operation will be stopped 11 3 8 About Cursor Key Which Points To OFF On Remote Control When the ON OFF button on th...

Страница 33: ... Dry Operation 12 1 3 1 Thermostat control The same as Cooling mode 12 1 4 Heating operation 12 1 4 1 Thermostat control Compressor is OFF when Intake Air Temperature Internal Setting Temperature 2 0 Compressor is ON after waiting for 3 minutes if the Intake Air Temperature Internal Setting Temperature Compressor OFF point 12 1 5 Automatic Operation Once AUTO mode is selected operation mode is det...

Страница 34: ...EATING rpm 1300 1140 1060 980 900 740 ii Auto Fan Speed Cooling Soft Dry Mode According to room temperature and setting temperature indoor fan speed is determined automatically The indoor fan will operate according to pattern below Fan speed Higher Medium Lower A b c d e f g h a b B Feedback control Immediately after the fan motor started feedback control is performed once every second During fan ...

Страница 35: ...de quiet operation comparing to normal operation The Quiet operation can be active or stop by pressing QUIET button on remote control Once Quiet mode is active the unit will continuously operate in QUIET Mode until cancel the mode by pressing QUIET button on remote control 12 3 4 Powerful operation To cooling or heating the room faster comparing to normal operation The POWERFUL operation can be ac...

Страница 36: ...ation Panel LED POWER TIMER QUIET POWERFUL Color Green Orange GREEN RED Light ON Operation ON Timer setting ON Quiet mode ON Powerful mode ON Light OFF Operation OFF Timer setting OFF Quiet mode OFF Powerful mode OFF Note If POWER LED blinks the possible operation of the unit is operating mode judgment or ON timer sampling If Timer LED blinks there is an abnormal operation occurs 12 3 7 Timer cont...

Страница 37: ... not stop within 30 seconds in a normal operation although the intake air temperature has reached the thermo off temperature However force stop by pressing the OFF ON button at the remote control is permitted or the Auto OFF ON button at indoor unit The reason for the compressor to force operation for minimum 30 seconds is to allow the refrigerant oil run in a full cycle and return back to the out...

Страница 38: ...ssor discharge temperature The change of frequency is as below 13 1 6 Low Operation Frequency Protection Control When the compressor operate frequency lower than 24Hz continued for 240 minutes the operation frequency will be changed to 23Hz for 2 minutes 13 1 7 Low Operation Frequency Protection Control If all following conditions exists the compressor will run with the frequency of 30 Hz Models R...

Страница 39: ...uency will adjust base on outdoor air temperature RE9NKX RE12NKX RE15NKX 13 2 2 Freeze Prevention Control 1 Frequency of the compressor For prevention of freezing of the indoor evaporator the frequency of the compressor will be changed according to the indoor piping temperature 2 Indoor Fan Control Indoor fan speed changes according to the indoor piping temperature 13 2 3 Dew Prevention Control To...

Страница 40: ...operation the indoor fan will run at the following speed when the compressor stops 3 Hot Start When the heating operation starts the indoor fan stops and the compressor runs with a certain frequency This is to prevent the cold airflow from blowing If the piping temperature rises to 19 and the indoor fan speed varies with the indoor piping temperature the hot start control is stopped 1 2 3 4 5 6 7 ...

Страница 41: ...41 13 3 2 Overload Protection Control The frequency for the compressor is determined by indoor piping temperature Indoor piping temp RE9NKX RE12NKX RE15NKX Indoor piping temp Indoor piping temp ...

Страница 42: ...utdoor temperature 35 C at cooling mode and 7 C at heating mode Compressor operates at rated frequency Different in the intake and outlet air temperatures Normal Value of electric current during operation Dusty condenser preventing heat radiation Excessive amount of refrigerant Measuring the air temperature different Measuring electric current during operation Measuring gas side pressure More than...

Страница 43: ...n be restarted using AUTO Switch on the indoor unit In forced operation the frequency for compressor and fan speed can not be changed and the signal receiving sound is different Normal Operation ON pep Forced Operation ON pep pep pep pep Stop pep Note Refer to the Diagnosis Code Table for the malfunction when forced operation is not available 14 2 2 Display of Error Code 1 Keeping the CHECK button...

Страница 44: ...disconnected H33 Incorrect connection of Indoor Outdoor cable Indoor outdoor supply voltage H97 Outdoor fan motor lock Twice within 30 minutes Outdoor fan motor H98 Indoor high pressure protection Air filter dirty Air circulation short circuit H99 Indoor heat exchanger anti freezing protection Indoor heat exchanger freezing Insufficient refrigerant Air filter dirty F11 Cooling Heating cycle change...

Страница 45: ...Failure to heed this caution may result in electric shocks 1 Open the intake grille and pull it to the horizontal position 2 Pull up the intake grille until it falls off 1 Remove the two caps at the discharge port right and left and then release the two screws on both sides 2 Pull out the front grille form the unit body Removal Procedure for Intake Grille Removal Procedure for Front Grille Cap Scr...

Страница 46: ...the whole electronic controller Be sure to avoid cracking of the supporting hook 4 Remove the control board complete Loose the screws of control board complete then the whole control board can be pulled out 1 Separate the drain hose and the drain plate 2 Pull out the discharge grille slightly Removal Procedure for Main Electronic Controller Removal Procedure for Main Electronic Controller Control ...

Страница 47: ...and pull out the whole evaporator 2 Loose the fixing screw of the cross flow fan 3 After removing the bearing indoor fan can be taken out from the left side 4 Lift up the indoor fan slightly and then pull the fan motor out Removal Procedure for Cross Flow Fan Fixing Screw Fixing board Bearing Fan motor ...

Страница 48: ...48 16 Exploded View and Replacement Pars List 16 1 Indoor Unit CS RE9NKX CS RE12NKX CS RE15NKX ...

Страница 49: ...46 CWA28C2547 CWA28C2546 17 POWER SUPPLY CORD COMPLETE 1 CWA20C3068 CWA20C3068 CWA20C3074 18 MAIN PCB 1 CWA73C5921 CWA73C5922 CWA73C5923 19 SENSOR 1 CWA50C2883 CWA50C2883 CWA50C2883 20 INDICATOR HOLDER 1 CWD933546 CWD933546 CWD933546 21 INDICATOR PCB 1 CWA746860 CWA746860 CWA746860 22 CONTROL BOARD TOP COVER 1 CWH131523 CWH131523 CWH131523 23 CONTROL BOARD BACK COVER 1 CWH131526 CWH131526 CWH13152...

Страница 50: ...50 16 2 Outdoor Unit CU RE9NKX ...

Страница 51: ... 1 CWB111026 17 TERMINAL COVER 1 CWH171041 18 SOUND PROOF BOARD 1 CWH15K1048 19 SOUND PROOF MATERIAL 1 CWG302731 20 SOUND PROOF MATERIAL 1 CWG302732 21 TUBE NOISE SUPPRESSOR 1 CWB141023 22 REACTOR 1 G0C193J00014 23 CONTROL BOX COMPLETE 1 CWH14C9273 24 TERMINAL BOARD ASS Y 1 CWA28K1248 25 SENSOR COMPLETE COMP 1 CWA50C2848 26 SENSOR COMPLETE PIPING 1 CWA50C2835 27 TUBE ASS Y CAPILLARY 1 CWT01C6046 2...

Страница 52: ...52 CU RE12NKX CU RE15NKX ...

Страница 53: ...AL COVER 1 CWH171048 CWH171048 18 SOUND PROOF BOARD 1 CWH15K1034 CWH15K1034 19 SOUND PROOF MATERIAL 1 CWG302703 CWG302609 20 SOUND PROOF MATERIAL 1 CWG302605 CWG302605 21 SOUND PROOF MATERIAL 1 CWG302693 22 TUBE NOISE SUPPRESSOR 1 CWB141023 CWB141023 23 REACTOR 1 G0C103J00034 G0C193J00011 24 CONTROL BOX COMPLETE 1 CWH14C9612 CWH14C9270 25 TERMINAL BOARD ASS Y 1 CWA28K1248 CWA28K1248 26 SENSOR COMP...

Отзывы: