97
4 To enter zone 2 area: (Press
continuosly for T
≥
5 secs)
Once T
≥
5secs
Enter Zone2
[range (50~99)]
Enter Zone1
Normal display
mode
5 Function & Options list:
Note: The functions described in the table may not be applicable to the model and may subject to change without
further notice.
Function
No
Name
Options Remark
1
Remote control number selection
A, B, C, D
2
Solar radiation sensitivity level adjustment
1, 2, 3, 4, 5
3
[iAUTO-X/iAUTO/iCOMF, Cool & Dry] mode set temperature [Low2]
selection
16°C ~ [High2]
4
[iAUTO-X/iAUTO/iCOMF, Cool & Dry] mode set temperature [High2]
selection
[Low2] ~ 30°C
5
Heat mode set temperature Low1 selection
16°C ~ [High1]
6
Heat mode set temperature High1 selection
[Low1] ~ 30°C
7
Filter cleaning enable/disable selection
00 / 01
8
nanoe-G default ON enable/disable selection
00 / 01
9
Dust sensor monitoring & LED enable/disable selection
00 / 01
10
Auto restart enable/disable selection
00 / 01
11
Dust sensor sensitivity level adjustment
1, 2, 3
Zone 1
12 ~ 49
Reserve
50
ECO demo ON
None (No display)
51
Light sensor check
None (No display)
52
nanoe-G / ECO sensor check
None (No display)
53
DOA check
None (No display)
54
Odor cut control selection [Enable (01) / Disable (00)]
00 / 01
55
Frequency tolerance selection [±3Hz (03) / ±7Hz (07)]
03 / 07
56
Fixed fan speed selection during heat mode compressor OFF
00 / 01
57
nanoe check
None (No display)
58
Heat mode thermo shift adjustment
-3°C ~ 3°C
59
Others (Cool & Dry) mode thermo shift adjustment
-3°C ~ 3°C
60
Deice start determination judgment temperature switching
00 / 01
61
Cool mode disable selection [Yes (01) / No (00)]
00 / 01
62
Heat mode disable selection [Yes (01) / No (00)]
00 / 01
63
Base pan heater selection [A/ b]
A / b
64
Fan Speed reduction during cool mode thermo-Off [Enable (01) /
Disable (00)]
00 / 01
Zone 2
65 ~ 99
Reserve