50
Condition of the air
conditioner
Insufficient refrigerant
(gas leakage)
Clogged capillary
tube
Short circuit in the
indoor unit
Heat radiation deficiency
of the outdoor unit
Insufficient
compression
Cooling mode
Low pressure
High pressure
Electric current
during operation
12
.
2
.
Re
l
at
i
onsh
i
p between the cond
i
t
i
on of a
i
r cond
i
t
i
oner and pressrue
and e
l
ectr
i
c current
12
.
3
.
D
i
agnos
i
s methods of a ma
l
funct
i
on of a compressor
.
N
ature of fau
l
t
I
nsuff
i
c
i
ent compress
i
ng
of a compressor
Loc
k
ed compressor
Symptom
Electric current during operation becomes approximately 80% lower
than the normal level.
The discharge tube of the compressor becomes abnormally hot
(normally 70~90
).
The difference between high pressure and low pressure becomes
almost zero.
Electric current reaches a high level abnormally, and the value exceeds
the limit of an ammeter. In some cases, a breaker turns off.
The compressor has a humming sound.
CS
-
PV9DKE
/
CU
-
PV9DKE
/
CS
-
PV12DKE
/
CU
-
PV12DKE
Содержание CS-PV9DKE