![Panasonic CS-PC12MKF Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/panasonic/cs-pc12mkf/cs-pc12mkf_service-manual_1507887051.webp)
51
14 Servicing Mode
14.1. Auto OFF/ON Button
1. AUTO OPERATION MODE
The Auto operation will be activated immediately once the Auto OFF/ON button is pressed. This operation can be used to
operate air conditioner with limited function if remote control is misplaced or malfunctioned.
2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the Auto OFF/ON button is pressed continuously for more than 5 seconds. A “beep”
sound will occur at the fifth second, in order to identify the starting of this operation.
3. VARIOUS SETTING MODE
The Various Setting Mode will be activated if (within 20 seconds of Test Run Operation) the Auto OFF/ON button is pressed
for more than 5 seconds. 2 “beep” sounds will be heard to identify the starting of this operation.
Under Various Setting mode, user could perform the following operation:
i) Remote control receiving sound OFF/ON
Press “Auto OFF/ON button” to toggle remote control receiving sound.
- Short “beep”: Turn ON remote control receiving sound.
- Long “beep”: Turn OFF remote control receiving sound.
After Auto OFF/ON Button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON Mode is
restarted.
ii) Remote Control Number switch
• There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit. The
indoor unit will only operate when received signal with same transmission code from remote control. This could prevent
signal interference when there are 2 or more indoor units installed nearby together.
• To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
• During Various Setting mode, after select the transmission code combination of remote control, press any button at
remote control to transmit and store the desired transmission code to the EEPROM.
• After signal is received, the various setting mode is cancelled and return to normal operation.
• If there is no code is transmitted or Auto OFF/ON button is not pressed within 20 seconds, the Various Setting mode will
be cancelled.
Содержание CS-PC12MKF
Страница 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 11: ...11 5 Dimensions 5 1 Indoor Unit 5 1 1 CS PC12MKF ...
Страница 12: ...12 5 1 2 CS PC18MKF CS PC24MKF ...
Страница 13: ...13 5 2 Outdoor Unit 5 2 1 CU PC12MKF CU PC18MKF ...
Страница 14: ...14 5 2 2 CU PC24MKF ...
Страница 15: ...15 6 Refrigeration Cycle Diagram ...
Страница 16: ...16 7 Block Diagram 7 1 CS PC12MKF ...
Страница 17: ...17 7 2 CS PC18MKF CS PC24MKF ...
Страница 21: ...21 9 Electronic Circuit Diagram 9 1 CS PC12MKF CU PC12MKF ...
Страница 22: ...22 9 2 CS PC18MKF CU PC18MKF ...
Страница 23: ...23 9 3 CS PC24MKF CU PC24MKF ...
Страница 24: ...24 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board 10 1 1 1 CS PC12MKF ...
Страница 25: ...25 10 1 1 2 CS PC18MKF CS PC24MKF ...
Страница 32: ...32 11 2 5 Wire Stripping And Connecting Requirement ...
Страница 56: ...56 16 1 1 3 To remove Discharge Grille ...
Страница 57: ...57 16 1 1 4 To remove Control Board 16 1 1 5 To remove Cross Flow Fan and Indoor Fan Motor ...
Страница 58: ...58 ...
Страница 60: ...60 16 2 1 3 To remove Discharge Grille ...
Страница 61: ...61 16 2 1 4 To remove Control Board 16 2 1 5 To remove Cross Flow Fan and Indoor Fan Motor ...
Страница 62: ...62 ...
Страница 63: ...63 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Страница 71: ...71 17 4 Cooling Capacity Performance Data CS CU PC12MKF 220V ...
Страница 72: ...72 CS CU PC12MKF 240V CS CU PC18MKF 220V ...
Страница 73: ...73 CS CU PC18MKF 240V ...
Страница 74: ...74 CS CU PC24MKF 220V ...
Страница 75: ...75 CS CU PC24MKF 240V ...
Страница 76: ...76 17 5 Sound Data CS PC18MKF ...
Страница 77: ...77 CS PC24MKF ...