53
10.4 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)
Purpose
o
To provide quiet cooling operation compare to normal operation.
Control condition
o
Quiet operation start condition
When “POWERFUL/QUIET” button at remote control is pressed twice.
QUIET will be shown on remote control display.
o
Quiet operation stop condition
When one of the following conditions is satisfied, quiet operation stops:
POWERFUL/QUIET button is pressed again.
Stop by OFF/ON switch.
Timer “off” activates.
ECONAVI button is pressed.
Mild Dry Cooling button is pressed.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if timer “on” activates, quiet operation maintains.
After off, when on back, quiet operation is not memorised.
Control contents
o
Fan speed is changed to Lo-.
10.5 Quiet Operation (Heating)
Purpose
o
To provide quiet heating operation compare to normal operation.
Control condition
o
Quiet operation start condition
When “POWERFUL/QUIET” button at remote control is pressed twice.
QUIET will be shown on remote control display.
o
Quiet operation stop condition
When one of the following conditions is satisfied, quiet operation stops:
POWERFUL/QUIET button is pressed again.
Stop by OFF/ON switch.
Timer “off” activates.
ECONAVI button is pressed.
Mild Dry Cooling button is pressed.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except
fan mode only.
During quiet operation, if timer “on” activates, quiet operation maintains.
After off, when on back, quiet operation is not memorised.
Control contents
o
Fan speed manual
Fan speed is changed to Lo-.
o
Fan Speed Auto
Fan speed is changed to Lo-.
10.6 Powerful Mode Operation
When the powerful mode is selected, the internal setting temperature will shift lower up to -2°C for Cooling, -1°C
for Soft Dry or higher up to 3.6°C for Heating than remote control setting temperature for 20 minutes to achieve
the setting temperature quickly.