14.11 nanoeX Operation
Generate nanoeX (water wrapped ion particle) to moisturize skin, provide deodorization & sterilization effect.
nanoeX operation start condition
o
During unit running at any operation mode, if nanoeX operation is activated, combination operation
(operation mode + nanoeX operation) starts.
o
During unit is OFF, if nanoeX operation is activated, nanoeX individual operation starts.
nanoeX operation stop condition
o
When OFF/ON button is pressed to stop the operation.
o
When nanoeX button is pressed.
o
When OFF Timer activates.
nanoeX operation pause condition
o
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoeX operation resume after
indoor fan restarts.
o
When indoor intake temperature
≥
35°C and < 5°C. nanoeX operation resume after indoor intake
temperature < 35°C or
≥
5°C continuously for 6 minutes.
Indoor
fan
control
o
During any operation mode combines with nanoeX operation, fan speed follows respective operation mode.
However, nanoeX system enabled when fan speed
≥
390 rpm to ensure proper negative ion distribution,
nanoeX system disabled when fan speed < 390 rpm.
o
During nanoeX individual operation, fan speed follow remote control setting. Auto Fan Speed for nanoeX
individual operation is cooling medium fan. Powerful & Quiet is disabled during nanoeX.
Airflow direction control
o
During any operation mode combines with nanoeX operation, airflow direction follows respective operation
mode.
o
During nanoeX individual operation, Air Swing follow remote control setting.
Timer
control
o
When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoeX
operation status.
o
When ON Timer activates during any operation, no change on current operation.
o
When OFF Timer activates during any operation, all operation stops and the latest nanoeX operation status
is saved.
Indicator
o
When nanoeX starts, nanoeX indicator ON.
Remote control receiving sound
o
Normal
Operation
nanoeX Operation
: Beep
o
nanoeX
Operation
Normal Operation
: Beep
o
Stop
nanoeX individual Operation : Beep
o
nanoeX individual Operation
Stop
: Long Beep
Power
failure
o
During nanoeX individual operation, if power failure occurs, after power resumes, nanoeX individual
operation resumes immediately.
o
During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.