background image

5

Power supply

Do not use a modifi ed cord, 
joint cord, extension cord or 
unspecifi ed cord to prevent 
overheating and fi re.

  

To prevent overheating, fi re or electric shock:
• Do not share the same power outlet with 

other equipment.

• Do not operate with wet hands.
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting or 

pulling out the power plug.

If the supply cord is damaged, it must be replaced 
by the manufacturer, service agent or similarly 
qualifi ed persons in order to avoid a hazard.

It is strongly recommended to be installed 
with Earth Leakage Circuit Breaker (ELCB) 
or Residual Current Device (RCD) to prevent 
electric shock or fi re.

To prevent overheating, fi re or electric shock:
• Insert the power plug properly.
• Dust on the power plug should be periodically 

wiped with a dry cloth.

Stop using the product if any abnormality/failure 
occurs and disconnect the power plug or turn 
off  the power switch and breaker.
(Risk of smoke/fi re/electric shock)
Examples of abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is 

observed.

• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is 

switched on for operation.

• The fan does not stop even if the operation is 

stopped.

Contact your local dealer immediately for 
maintenance/repair.

This equipment must be earthed to prevent 
electrical shock or fi re.

Prevent electric shock by switching off  the 
power supply and unplug:

 -Before cleaning or servicing,
 -When extended non-use, or
 -During abnormally strong lightning activity.

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, 
benzine, thinner or scouring powder to avoid 
damage or corrosion at the unit.
Do not use for preservation of precise 
equipment, food, animals, plants, artwork 
or other objects. This may cause quality 
deterioration, etc.
Do not use any combustible equipment in front 
of the airfl ow outlet to avoid fi re propagation.
Do not expose plants or pet directly to airfl ow 
to avoid injury, etc.

Do not touch the sharp aluminium fi n, 
sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 
the fl oor. After waxing, aerate the room 
properly before operating the unit.
Do not install the unit in oily and smoky areas 
to prevent damage to the unit.
Do not dismantle the unit for cleaning purpose 
to avoid injury.
Do not step onto an unstable bench when 
cleaning the unit to avoid injury.
Do not place a vase or water container on the 
unit. Water may enter the unit and degrade the 
insulation. This may cause an electric shock.
Do not open window or door for long time during 
operation, it may lead to ineffi  cient power usage 
and uncomfortable temperature changes.
Prevent water leakage by ensuring drainage 
pipe is:

 -Connected properly,
 -Kept clear of gutters and containers, or
 -Not immersed in water

After a long period of use or use with any 
combustible equipment, aerate the room 
regularly.
After a long period of use, make sure the 
installation rack does not deteriorate to prevent 
the unit from falling down.

Содержание CS-MZ16ZKE

Страница 1: ...ZKE CU Z50ZKE CS XZ20ZKEW H CS XZ25ZKEW H CS XZ35ZKEW H CS XZ42ZKEW H CU Z20ZKE CU Z25ZKE CU Z35ZKE CU Z42ZKE Multi Split CU 2Z35TBE CU 2Z41TBE CU 2Z50TBE CU 3Z52TBE CU 3Z68TBE CU 4Z68TBE CU 4Z80TBE C...

Страница 2: ...e Split System or Multi Split System Air Conditioner to suit your needs For complete product features please refer to catalogue Inserting the batteries 1 2 3 1 Pull out the back cover of remote contro...

Страница 3: ...control display 3 Press TEMP UP TEMP DOWN to select the desired temperature Up Down Selection range 16 0 C 30 0 C 60 F 86 F Press for approximately 10 seconds to show the temperature as C or F 2 Pres...

Страница 4: ...cialist to clean the internal parts repair install remove disassemble and reinstall the unit Improper installation and handling will cause leakage electric shock or re Con rm with authorised dealer or...

Страница 5: ...cal shock or re Prevent electric shock by switching o the power supply and unplug Before cleaning or servicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit...

Страница 6: ...he working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrige...

Страница 7: ...ironmental e ects such as the danger of water collecting and freezing in relief pipes or the accumulation of dirt and debris h Expansion and contraction of long runs piping in refrigerating systems sh...

Страница 8: ...ignition and hot metal surfaces away 2 3 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is a...

Страница 9: ...e refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks t...

Страница 10: ...nt in the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental e ects The check shall a...

Страница 11: ...pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any potential ignition sources and there is ventilation available OFN oxygen free nitrogen type of inert gas 9 Ch...

Страница 12: ...ardous condition when charging or discharging the refrigerant To avoid re or explosion dissipate static electricity during transfer by grounding and bonding containers and equipment before charging di...

Страница 13: ...acuated to an acceptable level to make certain that ammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppli...

Страница 14: ...ow the remote control setting If nanoe X is activated before the unit is turned o the nanoe X operation will resume when the unit is turned on This includes when TIMER ON is set Press the button again...

Страница 15: ...time This operation provides you with a comfortable environment while sleeping It will automatically adjust the sleep pattern temperature during the activation period The indoor unit indicator will di...

Страница 16: ...ion This control is not applicable when TIMER is set To Learn More Single Single split system Multi Multi split system Operation mode It is possible to operate the indoor units individually or simulta...

Страница 17: ...Z50ZKE CU Z71ZKE 2 CU 2Z35TBE CU 2Z41TBE CU 2Z50TBE CU 3Z52TBE CU 3Z68TBE CU 4Z68TBE CU 4Z80TBE CU 5Z90TBE Inside Cleaning This function is to enhance the inside cleaning of the air conditioner indoo...

Страница 18: ...ugh items e g ngernails tools rings etc Wipe the unit gently with a soft damp cloth The coils and fans should be cleaned periodically by an authorised dealer Outdoor unit Clean the debris that surroun...

Страница 19: ...hen room temperature increase Indoor fan stops occasionally during heating operation To avoid unintended cooling e ect Indoor fan stops occasionally during automatic fan speed setting This is to help...

Страница 20: ...ly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Check...

Страница 21: ...the air inlets and outlet vents Use AUTO OFF ON on the unit to select COOL or HEAT mode For details refer The remote control is missing or a malfunction has occurred above After 15 minutes of operatio...

Страница 22: ...35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand cod...

Страница 23: ...y or dealer and ask for the correct method of disposal Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies w...

Страница 24: ...a branch of Panasonic Marketing Europe GmbH Maxis 2 Western Road Bracknell Berkshire RG12 1RT Manufactured by Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Importer Panasonic...