11
3-5. Shape the Indoor Side Tubing
(1) Arrangement of tubing by directions
a) Right or left tubing
Cut out the corner of the right/left frame with a
hacksaw or the like. (Figs. 20 and 21)
b) Right-rear or left-rear tubing
In this case, the corner of the frame need not be
cut.
(2) To mount the indoor unit on the rear panel:
Hang the 2 mounting slots of the unit on the
upper tabs of the rear panel. (Fig. 22)
3-6. Wiring Instructions
General precautions on wiring
(1) Before wiring, confirm the rated voltage of the unit as
shown on its nameplate, then carry out the wiring
closely following the wiring diagram.
(2) Provide a power outlet to be used exclusively for
each unit, with a power supply disconnect and cir-
cuit breaker for overcurrent protection provided in
the exclusive line.
(3) To prevent possible hazard due to insulation failure,
the unit must be grounded.
(4) Each wiring connection must be done tightly and in
accordance with the wiring system diagram. Wrong
wiring may cause the unit to misoperate or become
damaged.
(5) Do not allow wiring to touch the refrigerant tubing,
compressor, or any moving parts of the fan.
(6) Unauthorized changes in the internal wiring can be
very dangerous. The manufacturer will accept no
responsibility for any damage or misoperation that
occurs as a result of such unauthorized changes.
Frame
Right tubing
outlet
Frame
Left tubing
outlet
Fig. 21
Fig. 22
Fig. 20
Содержание CS-MKS7NKU
Страница 23: ...3 DIMENSIONAL DATA Indoor Unit CS MKS7NKU CS MKS9NKU CS MKS12NKU Unit inch mm 852 0 0010 215 00 0 23...
Страница 24: ...Unit inch mm Indoor Unit CS MKS18NKU CS MKS24NKU CS MKS18NKU CS MKS24NKU 852 0 0010 216 00 0 24...
Страница 43: ......
Страница 44: ...Operating Instructions CS MKS7NKU CS MKS9NKU CS MKS12NKU APPENDIX A 852 6 4181 214 00 2 A 1...
Страница 70: ...Operating Instructions CS MKS18NKU CS MKS24NKU 852 6 4181 215 00 1 APPENDIX B A 2...
Страница 117: ......
Страница 118: ...DC1111 0...