background image

    APPLICABLE INDOOR UNITS

CU-3KS19NBU

CU-4KS24NBU

CU-4KS31NBU

Multi-Outdoor Unit

Indoor Unit

3-Room

4-Room

4-Room

CS-MKS7NKU

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

NO

YES

YES

CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU

Wall Mounted Type

CU-3KS19NBU

CU-4KS24NBU

CU-4KS31NBU

Multi-Outdoor Unit

Indoor Unit

3-Room

4-Room

4-Room

CS-MKS9NB4U

&

CZ-18BT1U

YES

YES

YES

YES

YES

YES

YES

YES

YES

CS-MKS12NB4U

&

CZ-18BT1U

CS-KS18NB4UW

&

CZ-18BT1U

Semi-Concealed Type

6

Содержание CS-MKS7NKU

Страница 1: ...laced with manufacturer s specified parts to prevent shock fire or other hazards Do not modify the original design without permission of manufacturer WARNING This service information is designed for e...

Страница 2: ...YES YES YES YES YES YES YES YES YES YES NO YES YES CS MKS9NKU CS MKS12NKU CS MKS18NKU CS MKS24NKU Wall Mounted Type CU 3KS19NBU CU 4KS24NBU CU 4KS31NBU Multi Outdoor Unit Indoor Unit 3 Room 4 Room 4...

Страница 3: ...connecting tube kit CZ 3F type Unit A Maximum pipe length 25 m 82 0 ft Unit B Maximum pipe length 25 m 82 0 ft Unit C Maximum pipe length 25 m 82 0 ft Indoor outdoor unit connection cables Flexible co...

Страница 4: ...imum pipe length 25 m 82 0 ft Unit B Maximum pipe length 25 m 82 0 ft Unit C Maximum pipe length 25 m 82 0 ft Unit D Maximum pipe length 25 m 82 0 ft Indoor outdoor unit connection cables Flexible cor...

Страница 5: ...ngth Outdoor Unit CU 3E19 Allowable piping length of each indoor unit min max 9 8 ft 82 0 ft 3 m 25 m Allowable total piping length of all indoor unit 164 0 ft 50 m or less Height difference between i...

Страница 6: ...he copper pipe Align center of piping to valves and then tighten with torque wrench to the specified torque as stated in the table Do not over tighten over tightening may cause gas leakage Piping size...

Страница 7: ...3 3 Ibf ft 18 N m with a torque wrench 7 Remove the valve caps of both of the 2 way valve and 3 way valve Position both of the valves to Open using a hexagonal wrench 5 32 4 mm 8 Mount valve caps onto...

Страница 8: ...it A Unit C Terminal Terminal Indoor Unit B Indoor Unit A Disconnect Switch Field supply Grounding wire Grounding wire min AWG16 Grounding wire min AWG16 Grounding wire min AWG16 Power Supply Single P...

Страница 9: ...terial shall withstand 248 F 120 C or higher Gas side pipes 10 1 7 Disposal Of Outdoor Unit Drain Water If a drain elbow is used the unit should be placed on a stand which is taller than 1 31 32 50 mm...

Страница 10: ...Unit Installation Diagram Allowable piping length Outdoor Unit CU 4E24 Allowable piping length of each indoor unit min max 9 8 ft 82 0 ft 3 m 25 m Allowable total piping length of all indoor unit 229...

Страница 11: ...ench to the specified torque as stated in the table Do not over tighten over tightening may cause gas leakage Piping size Torque 1 4 6 35 mm 13 3 Ibf ft 18 N m 1 8 kgf m 3 8 9 52 mm 31 0 Ibf ft 42 N m...

Страница 12: ...of 13 3 Ibf ft 18 N m with a torque wrench 7 Remove the valve caps of both the 2 way valve and 3 way valve Position both of the valves to Open using a hexagonal wrench 5 32 4 mm 8 Mount valve caps ont...

Страница 13: ...g wire Power Supply Single Phase 208 230V 60Hz min AWG12 Grounding wire min AWG16 208 230V min AWG16 208 230V min AWG16 208 230V min AWG16 Grounding wire min AWG16 208 230V min AWG16 208 230V min AWG1...