Selecting the Installation Location
1
Selecting the Piping
2
3
No.
No.
No.
Accessory part
Accessory part
Accessory part
Qty.
Qty.
Qty.
Piping insulation
Band
Remote control
Battery
Remote control holder
Drain joint
Pattern
Remote control holder
fixing screw
Pattern fixing screw
1
2
6
3
4
5
7
8
9
Indoor Unit Accessory Parts
2
4
2
1
2
1
1
1
4
Required Materials
Product name Remarks
VP20 (outer diameter ø26) ; also sockets, elbows and other
parts as necessary
PVC adhesive
For refrigerant piping insulation
(foamed polyethylene with a thickness of 8 mm or more)
For drain piping insulation
(foamed polyethylene with a thickness of 10 mm or more)
4
×
1.5 mm
2
flexible cord, type designation 245 IEC 57 (H05RN-F)
(See "Connecting the Indoor/Outdoor Connecting Cable".)
Hanging bolts (M10) (4) and nuts (12), Flat washers (8)
Rigid PVC pipe
Adhesive
Insulation
Indoor/outdoor
connecting cable
Hanging bolt related parts
Other Items to be Prepared (Locally Purchased )
Determine the location with the agreement of the customer.
Indoor unit
The location should be strong enough to support the main unit without vibration.
There should not be any heat or steam sources nearby.
Drainage should be easy. Avoid locating the drain port close to ditches
(domestic wastewater).
Avoid locations above entrances and exits.
Ensure the distances indicated by the marks in the illustration.
Ensure sufficient space for installation and servicing.
The ceiling surface (lower surface) should be level.
Locate the indoor unit at least 1 m or more away from a TV, radio, wireless
equipment, antenna cables and fluorescent lights, and 2 m or more away
from a telephone.
Note that if the air conditioning unit is installed near an electronically lit
fluorescent light (inverter, rapid start type, etc.), it may not receive the
remote control signals.
To Drill a Hole in the Wall and
Install a Sleeve of Piping
Indoor Unit Installation Diagram
Part name Part number
Decorative grille
CZ-BT20P
(white)
* See the Outdoor Unit Installation
Instructions.
CAUTION
When the wall is hollow,
please be sure to use the
sleeve for tube ass'y to
prevent dangers caused by
mice biting the connecting
cable.
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes
about 15 mm from the wall.
4. Finish by sealing the sleeve with
putty or caulking compound at the
final stage.
Liquid side
Gas side
ø 6.35 (1/4") t 0.8
ø 9.52 (3/8") t 0.8
• Prepare the piping set shown in the table
below or equivalent products for the
refrigerant piping.
Attaching the remote control holder to the wall
Remote control mounting location
Signals may not be transmitted and received correctly when
the remote control is operated while in the holder. Take the
remote control in your hand to operate the unit.
Mount the holder in a location that is not subject to the
effects of heat (direct sunlight and stoves, etc.).
Bushing for
tube ass'y
15 mm
Wall
Sleeve for
tube ass'y
ø70 through
hole
Putty or caulking
compound
Approx.
5 - 7 mm
Outdoor
Indoor
Remote control holder
fixing screws
Remote control
holder
Remote
control 3
5
6
Ceiling
Indoor unit
20 cm
or more
Decorative grille
Wall
Discharge vent
Intake
19 cm or
more
30 cm or
more
30 cm or
more
CS
-M
E
7C
B
1P
/
C
S
-M
E
10CB1
P
/
CS
-M
E
12CB1
P
/
CS
-M
E
14CB1
P
/
CS
-M
E
10CD3
P
/
CS
-M
E
14
CD3P
31
Содержание CS-ME10CB1P
Страница 5: ...3 2 INDOOR UNIT 5 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 6: ...6 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 9: ...9 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 10: ...5 2 Grille 10 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 11: ...5 3 Duct Type 11 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 12: ...6 Refrigeration Cycle Diagram 12 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 15: ...8 2 Duct Type CS ME10CD3P ME14CD3P 15 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 19: ...19 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 60: ...60 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 61: ...61 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...
Страница 62: ...62 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P ...