33

Cleaning the Air Conditioner

To

 Learn More... / Cleaning the 

Air Conditioner

Aluminium 

fi

 n

Front panel

Air 

fi

 lters

nanoe

TM

-G Generator

Cleaning has to be carried out at regular 

intervals to ensure the unit is at optimal 

performance. A dirty unit may cause 

malfunction and you may retrieve “H 99” 

error code. Consult an authorised dealer.

• Before cleaning, switch off the power 

supply and unplug the unit.

• Do not touch the aluminium 

fi

 n as the sharp 

parts may cause injury.

• Do not use benzine, thinner or scouring 

powder.

• Use soap (  pH 7) or neutral household 

detergent only.

• Do not use water hotter than 40 °C / 104 °F.

Indoor unit

Outdoor unit

Clean the debris that surround 

the unit.

Clear any blockage from the 

drain pipe.

nanoe

TM

-G Generator

Once every 2 weeks

• Clean with dry cotton bud.

• Do not touch during operation.

Air 

fi

 lters

Once every 2 weeks

• Wash/rinse  the 

fi

 lters gently 

with water to avoid damaging 

the surface.

• Dry  the 

fi

 lters thoroughly under a shade, 

away from 

fi

 re or direct sunlight.

• Replace any damaged 

fi

 lters.

Remove air 

fi

 lter

Attach air 

fi

 lter

Remove from the unit

Insert into the unit

Indoor unit

Do handle the unit surface 

with care to avoid scratches 

by sharp or rough items (e.g. 

fi

 ngernails, tools, rings, etc). 

Wipe the unit gently with a soft 

damp cloth.
The coils and fans should be cleaned 

periodically by an authorised dealer.

Front panel

Wash gently and dry.

How to remove front panel

2

  

Slide the front 

panel to right 

A

 and pull 

out 

B

.

1

 

Raise up.

B

A

Close it securely

2

  

Match and 

push in.

1

 

Hold horizontally.

3

 

Close down.

4

  Press both ends and center of the front 

panel.

English

Содержание CS-LU18ZKA

Страница 1: ...these operating instructions thoroughly and keep them for future reference Before installation the installer should Read the Installation Instructions then request the customer keep them for future re...

Страница 2: ...time Press for approximately 5 seconds to show the time as 12 hour am pm or 24 hour 2 Press to confirm 0 POWERFUL ECO FAN SPEED QUIET ON OFF TIMER POWERFUL ECO FAN SPEED QUIET ON OFF TIMER A B Use th...

Страница 3: ...ly 10 seconds to show the temperature as C or F Table of Contents Safety Precautions 22 29 How to Use 30 31 To Learn More 32 Cleaning the Air Conditioner 33 Troubleshooting 34 36 Information 37 Access...

Страница 4: ...plosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not...

Страница 5: ...lectric shock nanoe G generator Do not touch the sharp pin which may cause injury Power supply Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire...

Страница 6: ...eal the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use...

Страница 7: ...the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised...

Страница 8: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 9: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Страница 10: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Страница 11: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Страница 12: ...uickly This operation is automatically stop after 20 minutes ECO To reduce power consumption for better energy saving without sacrificing comfort To switch between POWERFUL ECO POWERFUL ECO exit setti...

Страница 13: ...ion can be cancelled by pressing the respective button until the sleep timer reaches 0 0h SLEEP How to Use To connect to a network For Wireless LAN Module operation setup please refer to Setup Instruc...

Страница 14: ...nd airflow direction This control is not applicable when TIMER is set nanoe X Inside Cleaning Depending on the unit s accumulated operation time the nanoe X may be activated only once a day after the...

Страница 15: ...the drain pipe nanoeTM G Generator Once every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid damaging...

Страница 16: ...nmental factors After extended use dust may cover the front panel grilles and the wall surrounding the unit The dust accumulation is due to the air purification effect of negative ions from nanoe G Re...

Страница 17: ...emote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14...

Страница 18: ...heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnorma...

Страница 19: ...be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a mildly f...

Страница 20: ...Memo...

Страница 21: ...Memo...

Страница 22: ...Printed in Malaysia Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ACXF55 35700 SY0822 0...

Отзывы: