7

2-4. Presence of 

fi

 re extinguisher

• If any hot work is to be conducted on the 

refrigeration equipment or any associated 

parts, appropriate fi re extinguishing 

equipment shall be available at hand.

• Have a dry powder or CO

2

 fi re extinguisher 

adjacent to the charging area.

2-5. No ignition sources

• No person carrying out work in relation to a 

refrigeration system which involves exposing 

any pipe work that contains or has contained 

fl ammable refrigerant shall use any sources 

of ignition in such a manner that it may lead 

to the risk of fi re or explosion. He/She must 

not be smoking when carrying out such work.

• All possible ignition sources, including 

cigarette smoking, should be kept suffi ciently 

far away from the site of installation, 

repairing, removing and disposal, during 

which fl ammable refrigerant can possibly be 

released to the surrounding space.

• Prior to work taking place, the area around 

the equipment is to be surveyed to make 

sure that there are no fl ammable hazards or 

ignition risks.

• “No Smoking” signs shall be displayed.

2-6. Ventilated area

• Ensure that the area is in the open or that it 

is adequately ventilated before breaking into 

the system or conducting any hot work.

• A degree of ventilation shall continue during 

the period that the work is carried out.

• The ventilation should safely disperse any 

released refrigerant and preferably expel it 

externally into the atmosphere.

2-7. Checks to the refrigeration equipment

• Where electrical components are being 

changed, they shall be fi t for the purpose 

and to the correct specifi cation.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• The following checks shall be applied to 

installations using fl ammable refrigerants.

 

- The charge size is in accordance with 

the room size within which the refrigerant 

containing parts are installed.

 

- The ventilation machinery and outlets are 

operating adequately and are not obstructed.

 

- If an indirect refrigerating circuit is being 

used, the secondary circuit shall be 

checked for the presence of refrigerant.

 

- Marking to the equipment continues to be 

visible and legible. Markings and signs that 

are illegible shall be corrected.

 

- Refrigeration pipe or components are 

installed in a position where they are unlikely 

to be exposed to any substance which may 

corrode refrigerant containing components, 

unless the components are constructed of 

materials which are inherently resistant to 

being corroded or are properly protected 

against being so corroded.

2-8. Checks to electrical devices

• Repair and maintenance to electrical 

components shall include initial safety 

checks and component inspection 

procedures.

• Initial safety checks shall include but not 

limit to:-

 

- That capacitors are discharged: this 

shall be done in a safe manner to avoid 

possibility of sparking.

 

- That there no live electrical components 

and wiring are exposed while charging, 

recovering or purging the system.

 

- That there is continuity of earth bonding.

• At all times the manufacturer’s maintenance 

and service guidelines shall be followed.

• If in doubt consult the manufacturer’s 

technical department for assistance.

• If a fault exists that could compromise safety, 

then no electrical supply shall be connected 

to the circuit until it is satisfactorily dealt with.

• If the fault cannot be corrected immediately 

but it is necessary to continue operation, an 

adequate temporary solution shall be used.

• The owner of the equipment must be 

informed or reported so all parties are 

advised thereinafter.

3. Repairs to sealed components

• During repairs to sealed components, all 

electrical supplies shall be disconnected 

from the equipment being worked upon prior 

to any removal of sealed covers, etc.

• If it is absolutely necessary to have an 

electrical supply to equipment during 

servicing, then a permanently operating 

form of leak detection shall be located at the 

most critical point to warn of a potentially 

hazardous situation.

• Particular attention shall be paid to the 

following to ensure that by working on 

electrical components, the casing is not 

altered in such a way that the level of 

protection is affected.

This shall include damage to cables, 

excessive number of connections, terminals 

not made to original specifi cation, damage to 

seals, incorrect fi tting of glands, etc.

• Ensure that apparatus is mounted securely.

• Ensure that seals or sealing materials have 

not degraded such that they no longer serve 

the purpose of preventing the ingress of 

fl ammable atmospheres.

• Replacement parts shall be in accordance 

with the manufacturer’s specifi cations.

NOTE: The use of silicon sealant may inhibit 

the effectiveness of some types of leak 

detection equipment.

Intrinsically safe components do not have to 

be isolated prior to working on them.

ACXF55-2301̲OL.ai   7   1/27/2020   7:19:38 PM

ACXF55-2301̲OL.ai   7   1/27/2020   7:19:38 PM

Содержание CS-KU12VKY Series

Страница 1: ...nasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference C POWERFUL SLEEP POWER CS TU12VKYW series CS TU18VKYW series CS RU12VKYW series CS RU18VKYW series CS RU24VKYW series CU TU12VKYW series CU TU18VKYW series CU RU12VKYW series CU RU18VKYW series CU RU24VKYW series C POWERFUL POWE...

Страница 2: ...C or higher degrees may save energy Default set temperature is 24 C in COOL mode as per country guidelines Use remote control around 7 m from the remote control receiver of the indoor unit ACXF55 2301 OL ai 2 1 27 2020 7 19 37 PM ACXF55 2301 OL ai 2 1 27 2020 7 19 37 PM ...

Страница 3: ...K CHECK Safety precautions 4 9 How to use 10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 7m ACXF55 2301 OL ai 3 1 27 2020 7 19 37 PM ACXF55 2301 OL ai 3 1 27 2020 7 19 37 PM ...

Страница 4: ...iances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handin...

Страница 5: ...410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut o...

Страница 6: ...uthorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall be...

Страница 7: ... any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall ...

Страница 8: ...and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing...

Страница 9: ...ied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrige...

Страница 10: ...rates at low fan speed to give a gentle cooling operation FAN To operate Air Con in Fan Only mode Indoor unit temp display will show set temp for AUTO COOL DRY mode and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides air circulation in the room C POWERFUL SLEEP POWER This operation is to achieve faster cooling This operatio...

Страница 11: ...y pressing or then press The nearest timer setting will be displayed and will activate in sequence When ON Timer is set the unit may start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick guide 11 ACXF55 2301 OL ai...

Страница 12: ...place any damaged filters Remove air filter Attach air filter Filter PM 2 5 filter Clean the filter whenever necessary Don t wash rinse the filter with water The surface of the filter shouldn t be rubbed with any object The filter shouldn t be pulled with strong force as it may get damaged Filter PM 2 5 filter This filter is applicable to specific models only Dust filters PM2 5 Filter Filter ACXF5...

Страница 13: ...The unit stops and some alpha numeric codes appear on IDU display 13 ACXF55 2301 OL ai 13 1 27 2020 7 19 41 PM ACXF55 2301 OL ai 13 1 27 2020 7 19 41 PM ...

Страница 14: ...nit Indoor unit Temperature Display will show for Full Load and for Half Load Setting Testing Guidelines Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Half Load 50 Auto OFF ON Button Indication for Half load Indication for Full load For Full Load For Half Lo...

Страница 15: ...tp www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental breaka...

Страница 16: ...ere is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 2301 OL ai 16 1 27 2020 7 19 42 PM ACXF55 23...

Отзывы: