Panasonic CS-KE36NKU Скачать руководство пользователя страница 2

Features

Controls

Microprocessor

Remote Controller

LCD Wireless Type, Temp. Sensor 

Built In

Temperature Control

IC Thermistor

Timer

24 Hour, Single Event, ON/OFF 

TIMER

Night Setback

Included

Unoccupied Mode

Included

High Power

Included

One Hour Timer

Included

Options

Refrigerant Line Set

Available

Fresh Air Intake

N/A

Airduct Extension

N/A

Hard Wired Remote Control

Available / Model Number-CZ-

RD515U

Indoor Frame Extension

N/A

Condensate Drain Pump

Available

Non-Removable, Locking  

Remote-Control Bracket

Available

Operating Range 

Indoor Air Intake Temp Outdoor Air Intake Temp

Cooling (Max)

95F DB/71F WB

115F DB

Cooling (Min)

67F DB/57F WB

0F DB

Heating (Max)

80F DB/67F WB

75F DB/65F WB

Heating (Min)

-DB/-WB

0F DB

Performance Data @ ARI Standard Conditions (230/208V)

Cooling
Total Capacity (BTU/H)

34,000 (10,900-34,000)

Sensible Capacity (BTU/H)

20,700

Latent Capacity (BTU/H)

13,300

SEER

16

Dehumidification (Pints/H)

10.64

Amps (A)

5-21.9

Power Inputs (W)

4,000

Outdoor Sound Rating (dB-A)

55

Heating
Total Capacity (BTU/H)

36,000 (14,000-36,000)

HSPF

9,0

Amps (A)

5-21.9

Max Amps

18.2/19.9

Power Inputs (W)

3,650/3,650

Outdoor Sounds Rating (dB-A)

56

Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon

Air Louver, Horizontal

Manual

Air Louver, Vertical

Automatic,Sweep,Step

Power Failure Automatic Restart

Included

Heating/Cooling Automatic 

Changeover

Included

Self-Diagnosis

Included

Air Filter

Washable, Anti-Mold