17.2 Breakdown Self Diagnosis Function
17.2.1 Self Diagnosis Function (Three Digits Alphanumeric Code)
Once abnormality has occurred during operation, the unit will stop its operation, and Timer LED blinks.
Although Timer LED goes off when power supply is turned off, if the unit is operated under a breakdown
condition, the LED will light up again.
In operation after breakdown repair, the Timer LED will no more blink. The last error code (abnormality) will be
stored in IC memory.
17.2.2 To Make a Diagnosis
1 Timer LED start to blink and the unit automatically stops the
operation.
2 Press the CHECK button on the remote controller continuously
for 5 seconds.
3 “- -” will be displayed on the remote controller display.
Note: Display only for “- -”. (No transmitting signal, no receiving
sound and no Power LED blinking.)
4 Press the “TIMER” ▲ or ▼ button on the remote controller. The
code “H00” (no abnormality) will be displayed and signal will be
transmitted to the main unit.
5 Every press of the button (up or down) will increase abnormality
numbers and transmit abnormality code signal to the main unit.
6 When the latest abnormality code on the main unit and code
transmitted from the remote controller are matched, power LED
will light up for 30 seconds and a beep sound (continuously for
4 seconds) will be heard. If no codes are matched, power LED will light up for 0.5 seconds and no sound will
be heard.
7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5
seconds or operating the unit for 30 seconds.
8 The LED will be off if the unit is turned off or the RESET button on the main unit is pressed.
17.2.3 To Display Memorized Error (Protective Operation) Status
1 Turn power on.
2 Press the CHECK button on the remote controller continuously for 5 seconds
3 “- -“ will be displayed on the remote controller display.
Note: Display only for “- -”. (No transmitting signal, no receiving sound and no Power LED blinking.)
4 Press the “TIMER” ▲ or ▼ button on the remote controller. The code “H00” (no abnormality) will be
displayed and signal will be transmitted to the main unit.
The power LED lights up. If no abnormality is stored in the memory, three beeps sound will be heard.
5 Every press of the button (up or down) will increase abnormality numbers and transmit abnormality code
signal to the main unit.
6 When the latest abnormality code on the main unit and code transmitted from the remote controller are
matched, power LED will light up for 30 seconds and a beep sound (continuously for 4 seconds) will be heard.
If no codes are matched, power LED will light up for 0.5 seconds and no sound will be heard.
7 The breakdown diagnosis mode will be canceled unless pressing the CHECK button continuously for 5
seconds or operating the unit for 30 seconds.
8 The same diagnosis can be repeated by turning power on again.
17.2.4 To Clear Memorized Error (Protective Operation) Status after Repair:
1 Turn power on (in standby condition).
2 Press the AUTO button for 5 seconds (A beep receiving sound) on the main unit to operate the unit at Forced
Cooling Operation modes.
3 Press the CHECK button on the remote controller for about 1 second with a pointed object to transmit signal
to main unit. A beep sound is heard from main unit and the data is cleared.
17.2.5 Temporary Operation (Depending On Breakdown Status)
1 Press the AUTO button (A beep receiving sound) on the main unit to operate the unit. (Remote control will
become possible.)
2 The unit can temporarily be used until repaired.
CLOCK
MODE
AIR COND
ITIONER
OFF/ON
SET
CHECK
RESET
AC
RC
ON
OFF
SET
CANCEL
1
2
3
TIMER
ECONAVI
+8/10°C
HEAT
MODE
TEMP
FAN SPEED
AIR SWING
POWERFUL/QUIE
T
+8/10°C
HEAT
Check
button
Содержание CS-HZ12RKE
Страница 28: ...28 11 1 4 Receiver Printed Circuit Board CN RCV 11 1 5 Fuse Printed Circuit Board ACL501 ACN501 ACL502 ACN502 ...
Страница 115: ...115 18 1 1 4 To remove control board Figure 6 18 1 1 5 To remove cross flow fan and indoor fan motor Figure 7 ...
Страница 116: ...116 Figure 8 Figure 9 ...
Страница 117: ...117 Figure 10 ...