background image

5

English

Safety precautions

To prevent overheating, 

fi

 re or electric shock:

• Do not share the same power outlet with other 

equipment.

• Do not operate with wet hands. 

• Do not over bend the power supply cord.
If the supply cord is damaged, it must be 

replaced by the manufacturer, service agent or 

similarly quali

fi

 ed persons in order to avoid a 

hazard.
It is strongly recommended to be installed 

with Earth Leakage Circuit Breaker (ELCB) 

or Residual Current Device (RCD) to prevent 

electric shock or 

fi

 re.

Stop using the product if any abnormality/failure 

occurs and disconnect the power plug or turn off 

the power switch and breaker.

(Risk of smoke/

fi

 re/electric shock) Examples of 

abnormality/failure

• The ELCB trips frequently.

• Burning smell is observed.

• Abnormal noise or vibration of the unit is 

observed.

• Water leaks from the indoor unit.

• Power cord or plug becomes abnormally hot.

• Fan speed cannot be controlled.

• The unit stops running immediately even if it is 

switched on for operation.

• The fan does not stop even if the operation is 

stopped.

Contact your local dealer immediately for 

maintenance/repair.

This equipment must be earthed to prevent 

electrical shock or 

fi

 re.

Prevent electric shock by switching off the power 

supply:

- Before cleaning or servicing,

- When extended non-use, or

- During abnormally strong lightning activity.

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzine, 

thinner or scouring powder to avoid damage or 

corrosion at the unit.

Do not use for preservation of precise equipment, 

food, animals, plants, artwork or other objects. 

This may cause quality deterioration, etc.
Do not use any combustible equipment in front of 

the air

fl

 ow outlet to avoid 

fi

 re propagation.

Do not expose plants or pet directly to air

fl

 ow to 

avoid injury, etc.

Do not touch the sharp aluminium 

fi

 n, 

sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 

the 

fl

 oor. After waxing, aerate the room properly 

before operating the unit.
Do not install the unit in oily and smoky areas to 

prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to 

avoid injury.
Do not step onto an unstable bench when 

cleaning the unit to avoid injury.
Do not place a vase or water container on the 

unit. Water may enter the unit and degrade the 

insulation. This may cause an electric shock.
Do not open window or door for long time during 

COOL/DRY mode operation.
Prevent water leakage by ensuring drainage 

pipe is:

- Connected properly,

- Kept clear of gutters and containers, or

- Not immersed in water
After a long period of use or use with any 

combustible equipment, aerate the room 

regularly.
After a long period of use, make sure the 

installation rack does not deteriorate to prevent 

the unit from falling down.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It may 

damage the remote control.

To prevent malfunction or damage of the remote 

control:

• Remove the batteries if the unit is not going to 

be used for a long period of time.

• New batteries of the same type must be 

inserted following the polarity stated.

F569176-SS0113-0_1EN.indd   5

F569176-SS0113-0_1EN.indd   5

17/04/2013   11:15:38

17/04/2013   11:15:38

Process Black

Process Black

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание CS-E12PB4EA

Страница 1: ...ς Comment utiliser l appareil Climatiseur 42 49 Consultez un revendeur agréé pour connaître la validité de la connectivité Instrucciones de funcionamiento Climatizador de aire 50 57 Consulte a un distribuidor autorizado para conocer la validez de la conectividad Instruções de funcionamento Aparelho de ar condicionado 58 65 Consulte o representante autorizado para validar a conectividade Инструкции...

Страница 2: ...ed on the first unit that turned on During operation HEAT and COOL modes cannot activate at the same time for different indoor units The power indicator blinks to indicate the indoor unit is standing by for a different operation mode Outdoor unit Indoor units Operation conditions Use this air conditioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature CU E9P...

Страница 3: ...Y AUTO HEAT COOL 2 Start stop the operation POWER Please note that the OFF indication is on to start 3 Select the desired temperature Selection range 16 C 30 C Operating the unit within the recommended temperature may save energy HEAT 20 C 24 C COOL 26 C 28 C DRY 1 C 2 C lower than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control wi...

Страница 4: ...ithout supervision Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do...

Страница 5: ...ise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or pet directly to airflow to avoid injury etc Do not touch the sharp aluminium fin sharp parts may cause injury Do not switch ON the indoor unit when waxing the floor After waxing aera...

Страница 6: ...ower consumption during COOL mode use curtains to screen off sunlight and outdoor heat DRY To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation POWERFUL QUIET To switch between powerful quiet QUIET POWERFUL NORMAL POWERFUL To reach temperature quickly POWERFUL Single This operation stops automatically after 20 minutes Multi Press the button again or turn ...

Страница 7: ...ple OFF at 22 00 Each time pressed OFF Cancel 2 Set the time 2 3 Confirm SET TIMER To cancel ON or OFF timer press ON or OFF to select respective or then press CANCEL If timer is cancelled manually or due to power failure you can restore the timer again by pressing ON or OFF to select respective or then press SET The nearest timer setting will be displayed and will activate in sequence When ON Tim...

Страница 8: ...bs to the CLOSE side Air Filter Installation 1 1 2 2 3 3 INDOOR UNIT Wipe the unit gently with a soft dry cloth AIR FILTER Vacuum wash and dry lt is recommended to clean the air filter every 6 weeks Do not operate without an air filter Wash rinse the air filter gently with water to avoid damage to the air filter surface Do not dry the part with a hair dryer or a stove Replace any damaged air filte...

Страница 9: ...utlet vents Noisy during operation Check if the unit has been installed at an incline Close the intake grille properly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Check if timers have been set The unit does not receive the signal from the remote contro...

Страница 10: ...13 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany F569176 SS0113 0_1EN indd 80 F569176 SS0113 0_1EN indd 80 17 04 2013 11 15 46 17 04 2013 11 15 46 Process Black Process Black AMP Air Conditioning www ampair co uk sales ampair co uk ...

Отзывы: