16.4.26 F96 (IPM Overheating)
Malfunction Decision Conditions
During operating of cooling and heating, when IPM temperature data (100°C) is detected by the IPM temperature
sensor.
Multi models only
o
Compressor Overheating: During operation of cooling and heating, when the compressor OL is activated.
o
Heat Sink Overheating: During operation of cooling and heating, when heat sink temperature data (90°C) is
detected by the heat sink temperature sensor.
Malfunction Caused
IPM overheats due to short circuit of hot discharge air flow.
IPM overheats due to defective of outdoor fan motor.
IPM overheats due to defective of internal circuitry of IPM.
IPM overheats due to defective IPM temperature sensor.
Multi Models Only
o
Compressor OL connector poor contact.
o
Compressor
OL
faulty.
Troubleshooting
Содержание CS-E12NKDW
Страница 15: ...15 Outdoor Unit U 2E15GBE Outdoor Unit U 2E18CBPG ...
Страница 16: ...16 Outdoor Unit U 3E18JBE ...
Страница 17: ...17 Outdoor Unit U 4E23JBE ...
Страница 18: ...18 ...
Страница 20: ...20 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 21: ...21 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E7NK CS E9NK CS E12NK CS E15NK ...
Страница 22: ...22 5 1 2 CS E18NK ...
Страница 23: ...23 5 2 Outdoor Unit 5 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD 5 2 2 CU E18NKD ...
Страница 24: ...24 6 Refrigeration Cycle Diagram 6 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Страница 25: ...25 6 2 CU E18NKD ...
Страница 26: ...26 7 Block Diagram 7 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Страница 27: ...27 7 2 CU E18NKD ...
Страница 28: ...28 8 Wiring Connection Diagram 8 1 Indoor Unit 8 1 1 CS E7NKDW CS E9NKDW CS E12NKDW CS E15NKDW ...
Страница 29: ...29 8 1 2 CS E18NKDW ...
Страница 30: ...30 8 2 Outdoor Unit 8 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Страница 31: ...31 8 2 2 CU E18NKD ...
Страница 32: ...32 9 Electronic Circuit Diagram 9 1 Indoor Unit 9 1 1 CS E7NKDW CS E9NKDW CS E12NKDW CS E15NKDW ...
Страница 33: ...33 9 1 2 CS E18NKDW ...
Страница 34: ...34 9 2 Outdoor Unit 9 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Страница 35: ...35 9 2 2 CU E18NKD ...
Страница 36: ...36 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Страница 38: ...38 10 1 5 Human Activity Sensor Printed Circuit Board ...
Страница 39: ...39 10 2 Outdoor Unit 10 2 1 CU E7NKD CU E9NKD CU E12NKD CU E15NKD ...
Страница 40: ...40 10 2 2 CU E18NKD ...
Страница 73: ...73 16 3 Error Code Table ...
Страница 74: ...74 ...
Страница 105: ...105 Figure 3 Figure 4 17 1 1 3 To remove discharge grille Figure 5 ...
Страница 106: ...106 17 1 1 4 To remove control board Figure 6 17 1 1 5 To remove cross flow fan and indoor fan motor Figure 7 Figure 8 ...
Страница 107: ...107 Figure 9 Figure 10 ...
Страница 109: ...109 Figure 14 Figure 15 17 2 1 4 To remove discharge grille Figure 16 ...
Страница 111: ...111 Figure 20 Figure 21 ...