Indoor Unit
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Sleep Mode Auto Control
• Indoor Fan operates at Low speed.
• Operation stops after 8 hours.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
–
Cooling : Fan rotates at Hi, Me and
SLo speed. Deodorizing
control is available.
–
Soft Dry: Fan rotates at SLo speed.
Deodorizing control
is available.
• Automatic air swing and manual adjusted
by remote control for vertical airflow.
• Manually adjusted by hand for horizontal airflow.
Airflow Direction Control
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
•
POWER
(Green) ........ Lights up in operation,
blinks in Automatic
Operation Mode
judging.
•
SLEEP
(Orange) ........ Lights up in Sleep
Mode Operation.
•
TIMER
(Orange) ....... Lights up in Timer
Setting.
•
POWERFUL
(Orange) .. Lights up in Powerful
Mode Operation.
•
ECONOMY
(Green) ..... Lights up in Economy
Mode Operation.
Operation Mode
• Cooling, Soft Dry, Air Circulation and
Automatic Mode.
Powerful Operation
• Reaches the desired room temperature
quickly.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
Starting Current Control
Economy Operation
• To reduce electrical power consumption.
7 Minutes Time Save Control
• Cooling Operation only.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor
unit discharge area.
• Fan motor is delayed for 1.6 seconds
when compressor starts simultaneously.
Содержание CS-C9BKNG
Страница 7: ...4 Dimensions 7 ...
Страница 8: ...5 Refrigeration Cycle Diagram 8 ...
Страница 9: ...6 Block Diagram 9 ...
Страница 10: ...7 Wiring Diagram 10 ...
Страница 31: ...3 For the embedded piping 31 ...
Страница 32: ... This can be used for left rear piping left bottom piping also 32 ...
Страница 59: ...14 Technical Data 59 ...
Страница 60: ...15 Exploded View 60 ...
Страница 66: ...How to use electronic circuit diagram 66 ...
Страница 69: ...20 3 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD BOTTOM VIEW 69 ...
Страница 70: ... MACC Printed in Malaysia 70 ...