Quiet Operation Control
(For Cooling Mode or cooling region of Soft Dry Mode)
•
Purpose of this operation is to provide quite cooling operation compare to normal operation.
•
When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased
2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.
•
Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
•
Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1h 30 min (1h QLo, 30 min QLo + 50).
After that, it goes back to Lo cool (However Quiet LED remains on).
•
Manual Airflow Direction:-
−
RPM control during Lo cool
−
RPM control during Hi & Me cool
•
Auto Airflow Direction:-
•
Quiet Mode Operation will stop if:-
−
Quiet mode button is pressed again.
−
Stopped by ON/OFF switch.
−
Timer OFF activates.
−
Powerful mode button is pressed.
−
When change mode to Air Circulation mode.
21
CS-C7CKP CU-C7CKP5 / CS-C9CKP CU-C9CKP5 / CS-C9CKP CU-C9CKP6 / CS-C12CKP CU-C12CKP5 / CS-C12CKP CU-C12CKP6
Содержание CS-C7CKP
Страница 15: ...15 CS C7CKP CU C7CKP5 CS C9CKP CU C9CKP5 CS C9CKP CU C9CKP6 CS C12CKP CU C12CKP5 CS C12CKP CU C12CKP6 ...
Страница 68: ...68 CS C7CKP CU C7CKP5 CS C9CKP CU C9CKP5 CS C9CKP CU C9CKP6 CS C12CKP CU C12CKP5 CS C12CKP CU C12CKP6 ...
Страница 69: ...69 CS C7CKP CU C7CKP5 CS C9CKP CU C9CKP5 CS C9CKP CU C9CKP6 CS C12CKP CU C12CKP5 CS C12CKP CU C12CKP6 ...
Страница 78: ...78 CS C7CKP CU C7CKP5 CS C9CKP CU C9CKP5 CS C9CKP CU C9CKP6 CS C12CKP CU C12CKP5 CS C12CKP CU C12CKP6 ...