25
Model
Pipe size
Gas side
Liquid side
Pipe cutter
Slan ted Rou gh
Pipe
Reamer
Point down
Bar
Bar
Copper pipe
Handle
Yoke
Cone
Clamp handle
Improper flaring
Slanted
When properly flared,the internal surface of the
flare will evenly shine and be of even thickness.
Since the flare part come into contact with the
connectors, carefully check the flare finish.
2. Remove burrs
Remove burrs from cut edges of pipes.
Turn the pipe end down to avoid the metal powder
entering the pipe.
●
●
Caution
If burrs are not removed, they may cause a gas leakage.
4. Tape the flaring portion to protect it from dust or damage.
Surface
Damaged
Cracket Uneven
Thickness
6/8
”
3/8
”
CS-C45FFH/
CU-C45FFH
10.3.
Piping and Drainage of Indoor Unit
10.3.1.
Preparation of piping
Fig.11
Fig.9
Fig.10
Fig.12
1. Cut the pipes and the cable
Use the accessory piping kit or pipes purchased locally
Measure the distance between the indoor and the
outdoor unit.
Cut the pipes a little longer than the measured distance.
Cut the cable a little longer than the pipe length.
●
●
●
●
3. Flaring the pipe
Insert the flare nuts, mounted on the connection ports
of both indoor and outdoor unit, onto the copper pipes.
Fit the copper pipe end into the bar of flare tool about
0.5-1.5mm higher.(See illustration)
Flare the pipe ends.
●
●
●
CS-C45FFH / CU-C45FFH
Содержание CS-C45FFH
Страница 8: ...8 4 Dimensions Indoor Unit CS C45FFH CU C45FFH 357 23 5X4 1880 16 5 56 Remote Controller ...
Страница 9: ...9 Outdoor Unit CS C45FFH CU C45FFH CU C45FFH 900 620 140 40 5 320 ...
Страница 42: ...CS C45FFH 15 Exploded View CS C45FFH CU C45FFH 4 2 1 3 5 7 11 12 10 6 15 18 17 21 19 16 20 42 8 9 35 36 ...
Страница 43: ...CS C45FFH CS C45FFH CU C45FFH 43 44 37 38 39 40 41 42 14 13 43 ...
Страница 45: ...17 Exploded View CS C45FFH CU C45FFH 45 ...
Страница 46: ...CS C45FFH CU C45FFH 46 ...