CARE & CLEANING

•  Wipe the unit gently with a soft, dry 

cloth.

•  It is recommended to clean the air 

filters once every 2 weeks.

•  Purchase the replacement filter if it 

is damaged.

  Part no.: CWD001217

INDOOR UNIT

AIR FILTER

•  This inspection is recommended 

before operating the air conditioner 

at every season.

•  Check if the remote control batteries 

needed to be replaced.

•  Ensure there is no obstruction at all 

air intake and outlet vents.

•  After the start of operation for 15 

 

minutes, it is normal if the 

temperature differences between 

air intake and outlet vents at indoor 

unit is:-

Operation Temperature difference

Cooling

 8°C

•  To dry the internal parts of the indoor 

unit, operate the unit for 2-3 hours 

using FAN operation.

•  Switch off the air conditioner and 

disconnect the power supply.

•  Remove the remote control batteries.

Switch off the power supply 

before cleaning

Washing Instructions

•  Do not use benzene, thinner or 

scouring powder.

•  Use soaps or neutral household 

detergent (  

pH7) only.

•  Do not use water with temperature 

higher than 40°C.

Pre-season Inspection

Preparation for extended 

Non-operation

INDOOR UNIT

Wipe gently.

l

  Clean the filter regularly as dirty filters will cause unpurified air, low cooling capacity, unpleasant smells and higher energy 

consumption.

l

  The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an 

authorized dealer to perform seasonal inspections in addition to regular cleaning.

l

  When thunder and lightning occur, stop the unit and switch off the power to protect the air-conditioner.

l

  If power resumed after a power failure,the operation will be restarted automatically under the previous operation mode.

l

  This air-conditioner may cease because of strong surge of voltage. If that happens, consult to an authorized dealer.

Hints

Remove

Vacuum, wash 

and dry.

AIR FILTER

Lose the two screws 

and open the 

grille,then remove.

Wash and dry.

INTAKE GRILLE

Screws

F566272_EN.indd   7

2008-12-16   9:59:33

Содержание CS-C18FFH

Страница 1: ...28FFH CU C28FFH ENGLISH Before operating the unit read these operating instructions thoroughly and keep them for future reference CONTENTS Safety Precautions 2 Product Overview 3 How to Operate 5 Care Cleaning 7 Product Specification 8 F566272_EN indd 1 2008 12 16 9 58 55 ...

Страница 2: ...ge DBT Dry Bulb Temperature WBT Wet Bulb Temperature Indoor Outdoor DBT WBT DBT WBT Maximum Temperature 32 23 43 26 Minimum Temperature 21 15 21 15 Different countries may have different colour coding for the wires Remove the cover of the outdoor unit before operating Use specified supply cord If the supply cord is damaged or needed to be replaced it must be replaced by the manufacturer or its ser...

Страница 3: ...and Indicator Panel Signal receiving Air intake Air filter n About To turn off or turn on the air conditioner Operation mode temperature fan speed and OFF ON timer should be set by remote control OFF ON operation button Auto OFF ON Button To operate the unit if the remote control is misplaced or malfunctioning Action Operation mode Press once Automatic Operation Press until beep sound Cooling Oper...

Страница 4: ...ay interfere with signal transmission Consult your dealer If the display is chaotic or can not be adjusted use a screwdriver to short the two terminals to reset the remote control to the original set by manufacturer Remote Control Preparation n About Remote Control Signal Insert batteries AAA or R03 The batteries can be used for approximately 1 year Remove the batteries if the unit is not to be us...

Страница 5: ... to prevent sunlight and heat from coming in Hint The unit will automatically select the operation mode according to the room temperature Once the operation mode is selected the unit will operate at the standard setting temperature as shown Room temperature Operation mode Standard setting temperature 23 C above Cool 25 C Below 23 C Dry 22 C The operation mode judging temperature and standard setti...

Страница 6: ...lly by using either ON or OFF timer Hints Troubleshooting l POWER indicator is blinking 30 minutes before ON timer is activated ä The unit is determining the operation mode by sensing the room temperature This happens when it has been set to AUTO operation mode l The timer indicator of the indoor unit will light up during the timer operation l To cancel either the ON or OFF timers press If you pre...

Страница 7: ... use benzene thinner or scouring powder Use soaps or neutral household detergent pH7 only Do not use water with temperature higher than 40 C n Pre season Inspection n Preparation for extended Non operation INDOOR UNIT Wipe gently l Clean the filter regularly as dirty filters will cause unpurified air low cooling capacity unpleasant smells and higher energy consumption l The unit will become dirty ...

Страница 8: ...tions 1m Distance Max cooling 53 54 53 54 Air Circulation m3 min 14 5 15 5 15 0 16 2 Product Weight kg 34 35 40 55 Dimensions H W D mm 1680 500 298 540 780 289 795 900 320 Ambient Temperature C 18 43 60 g for air purging is not included Test conditions 1 Cooling Indoor Dry Bulb Temp C 27 Outdoor Dry Bulb Temp C 35 Wet Bulb Temp C 19 Wet Bulb Temp C 24 2 Standard piping length 5 m Includes Indoor U...

Страница 9: ...ng operation Circuit breaker switches off frequently Water foreign particles have entered the Remote Control Power cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly NON SERVICEABLE CRITERIAS F0812 3 F566272 F566272_EN_back indd 22 2008 12 16 9 57 58 ...

Отзывы: