![Panasonic CS-C18DKD Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/panasonic/cs-c18dkd/cs-c18dkd_service-manual_256663047.webp)
1.
Confirm that both the 3-way valves are set to the open
position.
•
Remove the valve caps and confirm that the valve caps
are in the raised position.
•
Be sure to use a hexagonal wrench to operate the valve
stems.
2.
Operate the unit for 10 to 15 minutes.
3.
Stop operation and wait for 3 minutes, then connect the
manifold gauge to the service port of the 3-way valve as
shown above.
•
Connect the manifold gauge to the gas side service
port.
4.
Air purging of the charge hose.
•
Open the Low pressure side valve of manifold gauge
slightly to purge air from the charge hose.
5.
Set the liquid side (High side) 3-way valve to the close
position.
6.
Operate the air conditioner at the cooling cycle and
stop it when the gauge indicates 0.1 MPa.
•
If the unit cannot be operated at the cooling (weather is
rather cool), press the Pump Down switch on the Indoor
unit.
•
So that the unit can be operated.
7.
Immediately set the gas side (Low side) 3-way valve to
the close position.
•
Do this quickly so that the gauge ends up indicating 0.1
to 0.3 MPa.
8.
Disconnect the manifold gauge, and mount both the
3-way valve’s caps and the service port caps.
•
Use torque wrench to tighten the service port nut to a
torque of 18 N.m.
•
Be sure to check for gas leakage.
11.1.2. Pumping down
Procedure:
47
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
Содержание CS-C18DKD
Страница 11: ...4 2 Outdoor Unit 4 2 1 CU C18DKD 11 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 12: ...4 2 2 CU C24DKD 12 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 13: ...5 Refrigeration Cycle Diagram 13 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 14: ...6 Block Diagram 14 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 15: ...7 Wiring Diagram CS C18DKD CU C18DKD CS C24DKD CU C24DKD 15 ...
Страница 16: ...CS C18DKD CU C18DKD CS C24DKD CU C24DKD 16 ...
Страница 29: ...9 Operating Instructions 29 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 30: ...30 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 31: ...31 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 32: ...32 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 33: ...33 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 34: ...34 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 39: ...3 For the embedded piping 39 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 59: ...59 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Страница 70: ...19 2 Remote Control 70 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...