32
12.7. Vertical Airflow Direction Control
12.7.1.
Auto Control
• When the vertical airflow direction is set to Auto using the remote control, the louver swings up and down as shown in the
diagram.
• When stop operation using the remote control, the discharge vent is reset, and stop at the closing position.
• During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that condition, the
louver will stop swinging and rest at the upper limit.
12.7.2.
Manual Control
• When the vertical airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflow
direction louver move up and down in the range shown in the diagram.
• The louver can be adjusted by pressing the button to the desired louver position.
• When stop operation using the remote control, the discharge vent is reset, and stop at the closing position.
12.8. Horizontal Airflow Direction Control
• The horizontal airflow direction louvers can be adjusted manually by hand.
12.9. Powerful Operation
•
To achieve the setting temperature quickly.
• When Powerful operation is set, the setting temperature will be automatically decreased 3
°
C internally against the present
setting temperature (Lower temperature limit: 16
°
C).
• This operation automatically will be running under SHi fan Speed (Cooling), Lo- Fan Speed (Soft Dry).
• Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically shift down 10
°
lower than previous setting.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10
°
downward.
• Powerful operation stops when:-
- Quiet/Powerful button is pressed again.
- Powerful operation has operate for 15 minutes.
- Stopped by OFF/ON operation button.
- Timer OFF activates.
-
Operation mode is changed.
Содержание CS-C12GKF
Страница 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C12GK ...
Страница 10: ...10 5 2 Outdoor Unit 5 2 1 CU C12GK ...
Страница 11: ...11 6 Refrigeration Cycle Diagram ...
Страница 12: ...12 7 Block Diagram ...
Страница 14: ...14 9 Electronic Circuit Diagram ...
Страница 15: ...15 10 Printed Circuit Board 10 1 Indoor Unit TOP VIEW ...
Страница 16: ...16 BOTTOM VIEW ...
Страница 17: ...17 10 2 Indicator TOP VIEW BOTTOM VIEW ...
Страница 46: ...46 ...
Страница 47: ...47 15 2 Indoor Fan Motor and Cross Flow Fan Removal Procedures ...
Страница 48: ...48 ...
Страница 49: ...49 16 Technical Data 16 1 Thermostat Characteristics Cooling Soft Dry ...
Страница 50: ...50 16 2 Operation Characteristics 16 2 1 CS C12GK CU C12GK ...
Страница 51: ...51 ...
Страница 53: ...53 ...