12.4. Auto OFF/ON Button
•
The “Auto OFF/ON Button” (behind the front grille) is used to operate the air conditioner if remote control is misplaced or
mulfunctioning.
•
Forced cooling operation is possible by pressing the “Auto OFF/ON Button” for more than 5s where “beep” sound is heard then
release the button.
•
User able to select remote control transmission code and toggle remote control signal receiving sound under various setting
mode.
•
To enter various setting mode:
−
Press the “Auto OFF/ON Button” continuously for 5s (“beep” sound is heard) and release.
−
Within 20s, press the “Auto OFF/ON Button” continuously for 5s again (2 “beep” sound is heard) and release.
−
Various setting mode has limit up to 20s. Then return to normal operation.
12.4.1. Toggle Remote Control Signal Receiving Sound
•
Under various setting mode, press the “Auto OFF/ON Button” to toggle the remote control sound.
−
Short “beep”: Turn ON remote control signal receiving sound.
−
Long “beep”: Turn OFF remote control signal receiving sound.
•
After “Auto OFF/ON Button” is pressed, the 20s counter for various setting mode is restarted.
12.4.2. Remote Control Transmission Code
•
There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor unit
will only operate when received signal with same transmission code from remote control. This could prevent signal interference
when there are 2 or more indoor unit installed nearby together.
•
To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
•
Under various setting mode, after select the transmission code combination of remote control, press any button of remote
control to transmit a signal to indoor unit. The transmission code will be stored in EEPROM.
•
After signal is received, the various setting mode is cancelled and return to normal operation.
55
CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU
Содержание CS-C12DKU
Страница 3: ...2 Functions ı 3 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 4: ...4 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 5: ...5 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 10: ...4 Dimensions 4 1 Indoor Unit Remote Control 10 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 11: ...4 2 Outdoor Unit CU C9DKU CU C12DKU 11 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 12: ...5 Refrigeration Cycle Diagram CS C9DKU CU C9DKU CS C12DKU CU C12DKU 12 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 13: ...6 Block Diagram CS C9DKU CU C9DKU CS C12DKU CU C12DKU 13 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 28: ...9 Operating Instructions 28 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 29: ...29 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 30: ...30 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 31: ...31 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 32: ...32 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 33: ...33 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 59: ...14 Technical Data 14 1 Thermostat characteristics 59 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 60: ...14 2 Operation characteristics 14 2 1 CS C9DK CU C9DK 60 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 61: ...61 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 62: ...14 2 2 CS C12DK CU C12DK 62 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 63: ...63 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 72: ...72 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 74: ...19 2 Remote Control 74 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 75: ...19 3 Print Pattern Indoor Unit Printed Circuit Board 75 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 76: ...76 CS C9DKU CU C9DKU CS C12DKU CU C12DKU ...
Страница 77: ...Indicator Printed Circuit Board 77 CS C9DKU CU C9DKU CS C12DKU CU C12DKU PHAAM Printed in Malaysia ...