74
12.15
E-ion operation
•
This operation provides clean air by producing negative ions to attract dust captured at the positively charged
active e-ion filters.
•
e-ion operation start condition
o
During unit running at any operation mode, if “e-ion” operation is selected, combination operation (operation
mode + e-ion operation) starts.
o
During unit is OFF, if “e-ion” operation is selected, e-ion individual operation starts.
•
e-ion operation stop condition
o
When “OFF/ON” button is pressed to stop the operation.
o
When “PATROL/e-ion” button is pressed.
o
When OFF Timer activates.
•
e-ion operation pause condition
o
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after
indoor fan restarts.
o
When indoor intake temperature 40°C. e-ion operation resume after indoor intake temperature < 40°C
continuously for 30 minutes.
•
Indoor
fan
control
o
During any operation mode combines with e-ion operation, fan speed follows respective operation mode.
o
During e-ion individual operation – only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
Speed button is pressed, no signal is sent to air conditioner, and no change on LCD display.
Auto Fan Speed for e-ion operation switches from SHi to Hi after 4 hours of operation.
•
Airflow direction control
o
During any operation mode combines with e-ion operation, airflow direction follows respective operation
mode.
o
During e-ion individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
signal is sent to air conditioner, and no change on LCD display.
•
Timer
control
o
When ON timer activates when unit stops, previous operation resumes and restored last saved e-ion
operation status.
o
When ON timer activates during any operation, no change and carry on current operation.
o
When OFF timer activates during any operation, all operation stops and the latest e-ion operation status is
saved.
•
Indicator
o
When e-ion operation starts, e-ion indicator ON.
•
Remote Control Receiving Sound
o
Normal
Operation
Î
e-ion Operation
: Beep
o
e-ion
Operation
Î
Normal Operation
: Beep
o
Stop
Î
e-ion individual Operation
: Beep
o
e-ion individual Operation
Î
Stop
:
Long
Beep
•
Power
failure
o
During e-ion individual operation, if power failure occurs, after power resumes, e-ion individual operation
resumes immediately.
o
During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.
o
e-ion operation status is not memorized after OFF the unit. After OFF, when the operation is ON again, air
conditioner operates without e-ion operation.
Содержание CS-A9KKD-2
Страница 3: ...3 18 Exploded View and Replacement Parts List 125 18 1 Indoor Unit 125 18 2 Outdoor Unit 131 ...
Страница 16: ...16 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 17: ...17 5 Dimensions 5 1 Indoor Unit 5 1 1 CS A9KKD 2 CS A12KKD 2 ...
Страница 18: ...18 5 1 2 CS A18KKD 2 CS A24KKD 2 CS A28KKD 2 ...
Страница 19: ...19 5 2 Outdoor Unit 5 2 1 CU A9KKD 2 5 2 2 CU A12KKD 2 ...
Страница 20: ...20 5 2 3 CU A18KKD 2 CU A24KKD 2 CU A28KKD 2 ...
Страница 21: ...21 6 Refrigeration Cycle Diagram 6 1 CS A9KKD 2 CU A9KKD 2 CS A12KKD 2 CU A12KKD 2 ...
Страница 22: ...22 6 2 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 CS A28KKD 2 CU A28KKD 2 ...
Страница 23: ...23 7 Block Diagram 7 1 CS A9KKD 2 CU A9KKD 2 ...
Страница 24: ...24 7 2 CS A12KKD 2 CU A12KKD 2 ...
Страница 25: ...25 7 3 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 ...
Страница 26: ...26 7 4 CS A28KKD 2 CU A28KKD 2 ...
Страница 31: ...31 9 Electronic Circuit Diagram 9 1 CS A9KKD 2 CU A9KKD 2 ...
Страница 32: ...32 9 2 CS A12KKD 2 CU A12KKD 2 ...
Страница 33: ...33 9 3 CS A18KKD 2 CU A18KKD 2 CS A24KKD 2 CU A24KKD 2 ...
Страница 34: ...34 9 4 CS A28KKD 2 CU A28KKD 2 ...
Страница 36: ...36 10 1 1 2 CS A28KKD 2 ...
Страница 39: ...39 10 1 7 Eco Patrol Printed Circuit Board ...
Страница 54: ...54 12 3 2 Soft Dry Operation Time Diagram For CS A18KKD 2 CU A18KKD 2 and CS A24KKD 2 CU A24KKD 2 ...
Страница 86: ...86 Normal Deice Time Diagram Overload Deice Time Diagram ...
Страница 91: ...91 a Normal Deice Time Diagram b Overload Deice Time Diagram ...
Страница 97: ...97 Figure 3 Figure 4 Figure 5 16 1 1 3 To remove discharge grille Figure 6 ...
Страница 99: ...99 Figure 10 Figure 11 ...
Страница 101: ...101 16 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Страница 103: ...103 Figure 21 Figure 22 Figure 23 ...
Страница 104: ...104 17 Technical Data 17 1 Thermostat Characteristics ...