Troubleshooting

19

Normal operation

Air conditioner has been
restar ted, but does not
operate for 3 minutes.

This is to protect the air conditioner.  Wait until
the air conditioner begins operating.

Soft Dry Mode Operation is a very gentle Cooling
Operation consisting primarily of dehumidifying.
The air conditioner may stop for approximately 6
minutes in order to prevent overcooling.
If the room temperature rises again, the operation
will recommence.

If the airflow begins before its temperature be-
come warm, it will cause an undesired cooling ef-
fect. In order to prevent this, the airflow will not
begin until it is sufficiently warm.
(The operation lamp will blink until the airflow
begins.)

This may be a damp smell exuded by the walls,
carpet, furniture or clothing in the room.

This is the sound of refrigerant flowing inside the
air conditioner unit.
This is the sound of reversing the freon flow in-
side the unit at the starting and finishing the de-
frosting during Heating operation.

Condensation occurs when the airflow from the
air conditioner cools the room air.

This is to remove the smell exuded by the
surroundings.

This is to melt the frost which has accumulated on the outdoor
unit (Defrosting Operation). This will take no longer than about
12 minutes, so wait for operation. (Frost accumulates on the
outdoor unit when the outdoor temperature is low and the hu-
midity is high.) Water comes out from the outdoor unit.

During Soft Dry Mode
Operation, the air condi-
tioner stops.

Airflow does not begin
immediately during Heating
Operation.

The room has a peculiar
odour.

A sound like water flowing
can be heard.  A noise that
sounds like the com-
pressed air releasing into
atmosphere

It seems that fog is coming
out from the air
conditioner.

Operation stops for about
12 minutes during heating.
(The operation lamp
blinks.)

During Automatic Airflow
Volume setting, indoor fan
stops occasionally.

Q

Is it okay?

A

This is the answer.

Содержание CS-A281KR

Страница 1: ...oom Air conditioner Operating Instructions Model CS A281KR Indoor CU A281KR Outdoor Before using your air conditioner please read this operating instructions carefully and keep it for future reference...

Страница 2: ...Troubleshooting 19 20 Normal operation Abnormal operation Call the dealer immediately Contents Safety Precautions 2 4 Installation precautions Operation precautions Name of Each Part 5 6 Indoor unit O...

Страница 3: ...e to property only This symbol with a white background denotes an action that is PROHIB ITED These symbols with a black background denote an action that is COM PULSORY Installation precautions Do not...

Страница 4: ...hock or fire Do not operate the unit with wet hands It could cause an electric shock Do not insert finger sticks or other objects into the units It could lead to physical injury and cause damage to th...

Страница 5: ...urposes Do not use for preservation pur poses It will affect food quality animals or plants Do not place combustor in the path of the airflow from the unit Incomplete combustion could cause toxic gas...

Страница 6: ...ner Vertical Airflow Direction Louver Air Outlet Vent Horizontal Airflow Direction Louver Manually adjusted Signal Receptor Operation Indication Lamps LED Air Intake Vents Air Outlet Vents Side Rear G...

Страница 7: ...ton Airflow Volume Selection Button Airflow Direction Manual Control Button Room Temperature Setting Button Operation Mode Selection Button Airflow Direction Auto Control Button Separate displays and...

Страница 8: ...purifying filter Insert the air filters Hold the tab to raise up slightly and then pull down Air filter Be careful not to hurt your hands by metal parts Air purifying filter Note Use under the follow...

Страница 9: ...to a heating unit or other heat source Signal received sound One short beep or one long beep Pull out the power plug or turn off the power breaker when The air conditioner is not going to be used for...

Страница 10: ...hen Timer or Sleep Mode is set Auto Restart Control For Heating 20 24 For Cooling 26 28 For Soft Dry 1 2 lower than room temperature Recommended temperature for health and comfort Operation Details AU...

Страница 11: ...lamp RED will light up Press once more to stop the operation each time the button is pressed Press to select airflow volume The display changes in the order Press to select room temperature Heating Co...

Страница 12: ...f there is a power failure OFF TIMER SET Note Regarding remote control If the current time is not set correctly correct Timer setting will not be possible When the Timer is set the current time displa...

Страница 13: ...etting TIME to increase 10 minutes each step to decrease 10 minutes each step The Timer indication lamp at main unit will light up LED colour Orange The Timer indication lamp at main unit will go off...

Страница 14: ...light up The sleep indication lamp on the main unit will switch off Information Cooling or Soft Dry Operation for Sleep Mode movement will start to avoid overcooling Heating Operation for Sleep Mode m...

Страница 15: ...ndication lamp will blink for 20 seconds and then light up If the button is pressed once more the air con ditioner will stop The operation indication lamp will switch off OFF ON remote control signal...

Страница 16: ...ed Clean the air filter regularly Blockage in the air filter reduces the airflow and lowers the cooling or heating Clean at least once every 2 weeks Otherwise about 6 of electricity cost will be waste...

Страница 17: ...n shine enter the room directly About 5 of electricity cost can be saved Proper airflow direction adjustment Set the air flow direction louvers horizontal for Cooling Operation and downwards for Heati...

Страница 18: ...bove 40 C could cause deformation and or discolouration Volatile liquids such as thinner or benzene may damage the air condi tioner Cleaning the air conditioner and air filters Once every 2 weeks is r...

Страница 19: ...g filters Re insert the filters correctly at the left and right with the side marked FRONT facing forward Dusty filters cannot be re used even if they are cleaned and washed Purchase replacement filte...

Страница 20: ...e sound of reversing the freon flow in side the unit at the starting and finishing the de frosting during Heating operation Condensation occurs when the airflow from the air conditioner cools the room...

Страница 21: ...closed Is the installation work slanted Is the front grille closed properly The air conditioner does not operate The air conditioner does not cool effectively Air conditioner operation noise too loud...

Страница 22: ...th the following code Green and yellow Earth Blue Neutral Brown Live If the colours of the wires in the main lead of this appliance do not correspond with the coloured markings indentifying the termin...

Страница 23: ...22 Note Please remember to record the following Model Number Serial Number Dealer s Name Date Purchased...

Страница 24: ...C8036 900 Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global Printed in Taiwan...

Отзывы: